Option

Parameter

Comments

 

Value

 

 

 

 

Ext Execute Copy

DISABLE*

If DISABLED, dynamic data, overlay data, etc. are not

 

ENABLE

allowed if the optional Form Count parameter is specified

 

as part of the Execute command.

 

 

 

 

If ENABLED, dynamic data, overlay data, etc. are allowed

 

 

within a form in which the Form Count parameter is

 

 

specified in the Execute command. In this case, the exact

 

 

same form (with identical dynamic data, etc.) is printed for

 

 

whatever the Form Count is. Also, each form is printed on

 

 

a separate page.

 

 

 

Host Form Length

DISABLE

DISABLE sets the form length to the value set from the

 

ENABLE*

front panel. ENABLE sets the printer page size equal to the

 

form length defined in the CREATE FORM mode.

 

 

 

 

 

Power On IGP/PGL

DISABLE

DISABLE puts printer in QUIET mode at power±up,

 

ENABLE*

otherwise ENABLE or LISTEN mode is active at

 

power±up.

 

 

 

 

 

Select SFCC

1 ± 255 decimal

Select any ASCII character from Table 1±5 on page 1±16

 

126 *

to set the binary pattern for the selected Special Function

 

Control Character. Default is decimal 126 (~).

 

 

 

 

 

Uppercase

DISABLE*

If ENABLED, all incoming data is converted to uppercase.

 

ENABLE

 

 

 

 

1±14

Introduction

Page 26
Image 26
Printronix ThermaLine Series manual Option Parameter Comments Value, Ext Execute Copy