d. The information for the data field is entered

 

dynamically during the Execute Form Mode.

 

(Refer to ªExecute Form: Dynamic Bar Code

 

Dataº on page 4±55 in the ªCommandsº

 

chapter.) Do not use the data field parameter to

 

enter data when the BFn;L parameters are used.

 

However, refer to the data field description for

 

available characters.

DARK

Optional parameter to produce darker looking bar

 

codes. Enter DARK. Refer to ªDark Printingº on page

 

4±10 for more information.

SR

Defines the starting row for the bar code. Enter a value

 

ranging from row 1 to one less than the length of the

 

form. Character row or dot row is specified based on

 

the Scale command (page 4±88), or use the CP.DP

 

format (page 4±7).

SC

Defines the starting column of the bar code. Enter a

 

value ranging from column 1 to one less than the width

 

of the form. Character column or dot column is

 

specified based on the Scale command (page 4±88), or

 

use the CP.DP format (page 4±7).

D

The printable character (delimiter) identifying the start

 

and finish of the data field. Enter any printable

 

character other than a slash (/), the SFCC, or a

 

character used within the data. The same character

 

must be used at both ends of the data field, but it will

 

not print with the data.

data field

Enter the data for the bar code. A null data field (no

 

characters) is not permitted. The data field can contain

 

any character including carriage returns and line feeds.

 

The length of the data field is variable; however, the

 

maximum length is usually limited to1024 bytes to

 

minimize potential reading errors.

NOTE: New lines (i.e. carriage returns/line feeds) are allowed in the PDF417 data field and as PDF417 dynamic data field input.

5±96

Bar Codes

Page 234
Image 234
Printronix ThermaLine Series manual Character other than a slash /, the SFCC, or a