D

The printable character (delimiter) identifying the start

 

and finish of the data field. Enter any printable

 

character other than a slash (/), the SFCC, or a

 

character used within the data. The same character

 

must be used at both ends of the data field, but it will

 

not print with the data.

data field

Enter the characters for the bar code data, restricted to

 

exactly 19 digits. Enter the Packaging Type Number,

 

followed by the 7 digit Manufacturing Number

 

(including Number System Character preceded by zero

 

if a UPC number). Enter the 9 digit Shipping Container

 

Serial Number. The characters available for the data

 

field are 0 through 9 (30 through 39 hex, respectively).

PDF

Optional parameter to enable printing of the human

 

readable data field. Enter PDF to print the data field. If

 

the parameter is not used, the human readable data will

 

not print. This parameter is not allowed if a null data

 

field was specified.

LOC

Optional parameter to identify the location of the

 

printable data field. The default value is B, locating the

 

human readable data below the bar code. A locates the

 

printable data field above bar code. To compensate for

 

printing the 0.1±inch high data, the height of the bar

 

code body is reduced 0.1 inch.

STOP

Ends the Bar Code command while the IGP/PGL

 

continues in the Create Form Mode. Enter STOP. If

 

STOP is not entered, an error message results.

NOTE: Refer to the Code 128C Character Set Table on page 5±48, for information on character sets.

Bar Codes

5±55

Page 193
Image 193
Printronix ThermaLine Series manual Must be used at both ends of the data field, but it will, Not print with the data