Desa BHDV37N/P, BHDV41N/P Fireplace Models HDV37N/P and HDV41N/P, Installing Log Assembly No

Page 25

OWNER’S MANUAL

FIREPLACE INSTALLATION

Continued

Fireplace Models HDV37N/P and HDV41N/P

1.Place log#1 (back log) on grate. Make sure the lower middle section of the log fits securely into the open area in back of grate (see Figure 53).

2.Place log #2 (two log assembly) onto pins on left front and middle section of the front burner (see Figure 54).

3.Place log #3 (crossover assembly) onto the front right pin on front burner with the crossover log resting in notch on back log (see Figure 55).

4.Place lava rock along sides and front of firebox bottom.

NOTICE: Do not put lava rock on burner or under burner. Placing lava rock on burner could cause performance problems.

It is not necessary to use all of the lava rock provided.

5.Pull ember material apart into pieces no larger than a dime. Place these pieces loosely onto the exposed section of the front burner and space between logs 2 and 3 where front burner is exposed (see Figure 56). This will create the glowing appearance as the flame touches the em- ber material. Do not block ports by us- ing too much ember material in one area. It is not necessary to use all of the em- ber material provided.

7.Replace the glass door. See Removing/ Replacing Glass Door, page 22.

WARNING: The glass door must be securely in place before running this fireplace. Do not run this fireplace if glass is missing or broken.

1

3

Figure 53 - Installing Log No. 1

2

Figure 55- Installing Log Assembly No. 3

Ember Material

Figure 54 - Installing Log Assembly No. 2

Figure 56 - Placing Ember Material on

Burner

104558

25

Image 25
Contents For Your Safety What to do if YOU Smell GAS For Your SafetyBHDV37N/P, HDV37N/P BHDV41N/P, and HDV41N/P DIRECT-VENT Fireplace NATURAL/PROPANE/LP Safety InformationProduct Identification Product FeaturesLocal Codes Glossary TermsClearances PRE-INSTALLATION PreparationLocation and Space Requirements Framing and FinishingLocation of Vent Termination PRE-INSTALLATION Preparation General VentingGeneral Venting Installation Precautions Venting InstallationInstallation Planning Installing Vent System in a ChaseSnorkel Termination Installation for Horizontal TerminationVent Pipe Connections Horizontal Venting Horizontal Termination ConfigurationsVenting with Two 90 Elbows Flat Ceiling Installation Installation for Vertical TerminationCathedral Ceiling Installation Vertical Horizontal H 1 + Min Max 20 max Vertical Termination ConfigurationsVertical Venting Parts Lists for Venting Kits and Components High Altitude InstallationVanguard Rigid Venting Vanguard Flexible VentingInstalling Optional Blower Accessory Fireplace InstallationInstalling GA3700/DA3610T Blowers Check GAS TypePlug in blower power cord Installation Items Needed Installing GAS Piping to Fireplace LocationPressure Testing Gas Supply Piping System Connecting Fireplace to GAS SupplyChecking GAS Connections Close manual shutoff valve see Fig- ure Pressure Testing Fireplace Gas ConnectionsBack View of Thermostat Base Installing Optional Wall Mounted Thermostat GWMT1Attaching Magnetic Decorative Brass Strips HDV Only REMOVING/REPLACING Glass DoorInstalling Rear Brick Panel and Retainer Brackets Installing Optional Brick Liner D8037/D8041Fireplace Models BHDV37N/P and BHDV41N/P Installing LOGS, Lava Rock and Glowing EmbersFireplace Models HDV37N/P and HDV41N/P Installing Log Assembly NoOperating Fireplace Ghrc Series Operation Operating Optional Blower AccessoryGhrct Series Operation Inspecting Burners Pilot AssemblyOperating Optional GWMT1 Wall Mounted Thermostat Burner Flame PatternGlass Door Cleaning and MaintenancePilot and Burners LogsObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement Wiring Diagram Replacement PartsTechnical Service Service HintsBHDV/HDV37N BHDV/HDV37P BHDV/HDV41N BHDV/HDV41P SpecificationsAccessories BHDV37N BHDV41N36 Illustrated Parts BreakdownDIRECT-VENT Fireplace BHDV37N BHDV41N Parts ListBHDV37P BHDV41P36 DIRECT-VENT Fireplace BHDV37P BHDV41P HDV37N DIRECT-VENT Fireplace HDV37N and HDV41N HDV37P HDV41P DIRECT-VENT Fireplace HDV37P and HDV41P Warranty Information

BHDV41N/P, BHDV37N/P, HDV37N/P, HDV41N/P specifications

The Desa HDV41N/P, HDV37N/P, BHDV37N/P, and BHDV41N/P are modern heating units designed to deliver efficient warmth and comfort in various residential and commercial spaces. These models are noted for their advanced features and technologies, which combine functionality and aesthetics.

One of the main features of these units is their energy efficiency. They utilize state-of-the-art technology to provide warmth while minimizing energy consumption. This makes them an environmentally friendly choice, ensuring that homeowners can enjoy a cozy atmosphere without significantly increasing their energy bills.

The design of the Desa series models is characterized by their sleek and attractive appearance. They are available in various finishes, allowing homeowners to choose a design that complements their interior décor. This not only enhances the aesthetic appeal of the room but also ensures that the heating unit blends seamlessly into the space.

Another significant characteristic of the Desa models is their versatile heating capabilities. They can accommodate a variety of room sizes, providing adequate heat regardless of the environment. Whether used in larger living areas or smaller spaces, these units are engineered to maintain a consistent and comfortable temperature.

The units come equipped with user-friendly controls, allowing for easy adjustments and optimal temperature settings. Many of the models feature programmable thermostats, enabling users to schedule heating cycles according to their lifestyles. This contributes to increased comfort and further adds to energy savings.

Safety is also a primary concern with the Desa heating units. They come with built-in safety features, such as automatic shut-off mechanisms and advanced flame sensors. These safety measures ensure peace of mind while using the units, safeguarding against potential hazards.

Additionally, the units are designed for easy installation and maintenance. Their straightforward installation process is complemented by durable construction, which minimizes the likelihood of breakdowns. Regular maintenance is simplified, allowing users to keep their heating systems in excellent working condition without significant effort.

In summary, the Desa HDV41N/P, HDV37N/P, BHDV37N/P, and BHDV41N/P heating units combine sophisticated technology, aesthetic design, versatility, user-friendly controls, safety features, and low maintenance requirements. They stand out as a superior choice for anyone looking to enhance their indoor climate while being mindful of energy consumption and design aesthetics.