Vermont Casting DV580, DV360 manual Table of Contents

Page 2

DV360/580 Series Direct Vent Gas Fireplace

Table of Contents

PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE.

Thank you and congratulations on your purchase of a CFM Corporation fireplace.

IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these

instructions may result in a possible fire hazard and will void the warranty.

 

Installation &

.....................................................................................................................................

3

 

 

Operating Instructions

Locating Your Fireplace

3

 

 

 

Fireplace Dimensions

4

 

 

 

Clearance to Combustibles

6

 

 

 

Mantels

6

 

 

 

Hearth

6

 

 

 

Framing & Finishing

7

 

 

 

Final Finishing

7

 

 

 

Gas Specifications

7

 

 

 

Gas Inlet and Manifold Pressures

7

 

 

 

High Elevations

8

 

 

 

Gas Line Installation

8

 

 

 

Remote ON/OFF Switch Installation

8

 

 

 

Alternate Switch Location

8

 

 

 

EB-1 Electrical Box

9

 

 

 

Electronic Gas Control Valve

9

 

 

 

Optional Top Vent Application

10

 

 

General Venting

General Venting

11

 

 

 

General Venting Information - Termination Location

12

 

 

 

General Information Assembling Vent Pipes

13

 

 

 

How to Use the Vent Graph

14

 

 

 

Rear Wall Vent Application & Installation

14

 

 

 

Vertical Sidewall Application & Installation

16

 

 

 

Below Grade Installation

20

 

 

 

Vertical Through-the-Roof Application & Installation

20

 

 

 

Venting Components

23

 

 

Operating Instructions

Glass Information

24

 

 

 

Louvre Removal

24

 

 

 

Window Frame Assembly Removal

24

 

 

 

Glass Cleaning

24

 

 

 

Installation of Optional Ceramic Panels

24

 

 

 

Replacement of Ceramic Hearth Panels

24

 

 

 

Installation of Logs

25

 

 

 

Burner Lava Rock Placement

28

 

 

 

Large Lava Rock

28

 

 

 

Flame & Temperature Adjustment

28

 

 

 

Flame Characteristics

28

 

 

 

Inspecting the Venting System

28

 

 

 

Lighting and Operating Instructions (Honeywell Gas Valve)

30

 

 

 

Lighting and Operating Instructions (SIT Valve)

31

 

 

 

Instructions for RF Comfort Valve

32

 

 

 

Troubleshooting Gas Control (Honeywell Gas Valve)

36

 

 

 

Troubleshooting Gas Control (SIT 820 Millivolt Gas Valve)

37

 

 

 

Troubleshooting Gas Control (SIT 822 Valve)

38

 

 

 

Troubleshooting Gas Cotnrol (SIT 822 w/Synetek Electronic Control)

39

 

 

 

Fuel Conversion Instructions

40

 

 

Maintenance

Cleaning the Standing Pilot Control System

44

 

 

Replacement Parts

...................................................................................................................................

45

 

 

Optional Accessories

Fan Kits

49

 

 

 

Hard (Direct) Wire Hook Up

49

 

 

 

Remote Controls

50

 

 

 

Ceramic Refractory Panels

50

 

 

 

Decorative Bay Windows

50

 

 

 

Decorative Frame Trim

50

 

 

 

Arch/Square Face Kit

51

 

 

For Use in Mobile Homes: Model DV360RMH

52

 

 

Warranty

...................................................................................................................................

55

 

2

Energuide

...................................................................................................................................

56

20010667

Image 2
Contents Direct Vent Gas Fireplace Table of Contents Installation & Operating Instructions Locating Your FireplaceFireplace Dimensions Installed as Top Vent DV360 DV580Fireplace Dimensions Installed as Rear Vent Framing DimensionsHearth Clearance to CombustiblesMantels Gas Specifications Framing And FinishingFinal Finishing Gas Inlet and Manifold PressuresAlternate Switch Location Gas Line InstallationRemote ON/OFF Switch Installation When purging gas line the front glass must be removedElectronic Gas Control Valve Ensure that the power to the supply lineEB-1 Electrical Box Optional Top Vent Application Complete conversionGeneral Venting Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationGeneral Information Assembling Vent Pipes Canadian InstallationsUSA Installations Flex Vent PipesRear Wall Vent Application How to Use the Vent GraphTwist Lock Pipes Rear Wall Vent Installation Twist Lock Pipe Zero clearance sleeve is only required for combustible wallsRear Wall Vent Installations Flex Vent Pipe Vertical Sidewall Application+ B = 17 Max Vertical Sidewall Installation Twist Lock Pipe Always install horizontal venting on a level planeVertical Sidewall Installation Flex Vent Pipe Horizontal length requirementBelow Grade Installation Vertical Through-the-Roof ApplicationVertical Through-the-Roof Installation Maximum elbow usageMin 610 mm Venting Components Operating Instructions DV360 Installation of LogsLog Identification Chart Logs DV360 DV580Log Rear Top logs must be placed properly onto notches DV580Refer to Figure Flame Characteristics Burner Lava Rock PlacementFlame & Temperature Adjustment Large Lava RockDV360 DV580Lighting and Operating Instructions To Turn Off Gas To HeaterValve in the on position Lighting InstructionsTurning Off the Gas to the Appliance On Manual Mode Shut Off ProcedureTransmitter Operation Off Mode Instructions for RF Comfort Control ValveFan Override During Auto Mode Delay Timer ModeAuto Mode Change Between F/C Temperature UnitsLED Count Service Action Auto PathOn Path Local Path Troubleshooting Honeywell VS8421 Remove Window Frame Assembly Before Service WorkTroubleshooting the Gas Control System SIT Nova 820 Millivolt ValveStart Troubleshooting the Gas Control System Burner Orifice Conversion DV360 Conversions must be completed by qualified personnelFuel Conversion Instructions Honeywell ValveUsing a 1/2 open end wrench remove the orifices. Fig Pilot Orifice Conversion Installation PrecautionsConversion Procedure Injector Orifice Size Matrix Logs May Be HOT MaintenanceCleaning the Standing Pilot Control System Burner and Burner CompartmentDV360/580 DV360/580 Description DV580 GACA4P0 Fuel Conversion Kits FK24 Fan Assembly Optional AccessoriesFK12 Fan Assembly Hard Direct Wire Hook UpCeramic Refractory Panels Remote ControlsInstallation Instructions Decorative Bay WindowsArch/Square Face Kit For Use in Mobile Homes Model DV360RMH Conversion Instructions9b.Units with Honeywell valve DV360/580 Series Direct Vent Gas Fireplace Limited Lifetime Warranty Efficiency Ratings AFUE%

DV580, DV360, DV360 specifications

Vermont Castings is a name synonymous with quality and craftsmanship in the world of fireplaces. Among their celebrated products, the DV580, DV360, and DV360 stand out for their advanced technology, efficiency, and aesthetic appeal. Each of these models offers unique features designed to enhance home heating while maintaining a focus on environmental responsibility.

The DV580 is a powerful direct vent gas stove that seamlessly combines traditional aesthetics with modern functionality. With its large viewing window, it creates a cozy ambiance while allowing users to enjoy the mesmerizing flames. One of its main features is the advanced burner system, which provides a realistic flame appearance. This model also boasts an impressive BTU output, allowing it to heat larger spaces efficiently. The unit is equipped with an electronic ignition, ensuring reliable start-ups even in cold weather.

The DV360, a slightly smaller but equally efficient model, offers versatility for various home settings. With its compact design, it can fit into tighter spaces without sacrificing heating capacity. The DV360 features a unique dual burner system, which promotes a more even and consistent flame. Its direct vent technology ensures that all combustion byproducts are vented outside, maintaining indoor air quality. This model also includes an adjustable flame height, giving users control over the intensity of the heat and ambiance.

In addition to performance, both the DV580 and DV360 prioritize energy efficiency. They are designed to operate with minimal emissions, making them an environmentally friendly choice for homeowners. With a variety of finish options and customizable face designs, these models can complement any home decor. Another key characteristic is the straightforward installation process, which allows homeowners the benefit of having their unit up and running in no time.

Overall, the Vermont Castings DV580, DV360, and DV360 models exemplify a harmonious blend of innovation, functionality, and style. They not only provide warmth but also contribute to the overall aesthetic of any space. With their commitment to quality and performance, Vermont Castings continues to set the standard for direct vent gas stoves, ensuring customers enjoy the best of both worlds: comfort and beauty in their homes.