Vermont Casting DV580, DV360 Installation of Logs, Log Identification Chart, Logs DV360 DV580

Page 25

 

Screw

Burner

Screw

 

Hearth Panels

 

Grate

 

 

 

 

 

Front of Unit

H100a

 

 

 

Fig. 48

Hearth panel location.

 

Installation of Logs

DV360/580 Series Direct Vent Gas Fireplace

Log Identification Chart

Logs

DV360

 

DV580

 

Log Front Left

20010673

 

E9

Log Front Right

20010672

 

E10

Log Rear

20010675

 

E8

Log Top Left

--

 

E12

Log Top Right

20010676

 

E13

Log Front Center

--

 

E11

Log Top Center

20010677

 

--

Log Overlay

20010674

 

--

 

 

 

 

Remove front glass. (Refer to “Window Frame As- sembly Removal” Section, Fig. 47) Remove logs from packaging.

As with all plastics — these are not toys and should be kept away from children and infants.

DV360

NOTE: Refer to Figure 49 for bracket and bend loca- tions.

1.Place the log front right. Hold the log with the pointed end toward the left. Place on top of burner toward the right. Slide the log toward the front until it comes in contact with the bracket at the front of the burner housing behind the burner tube. (Fig. 49) Adjust the log until the pointed end on the left is aligned with the left edge of the bracket. (Fig. 50) NOTE: Gently push down on the right rear of the log so the pilot front shield cuts slightly into the log. This will help to ensure proper log position.

Left Edge

Pilot Front

 

of Bracket

Shield

Rear Log

 

 

Stop

 

Bracket

Bracket

 

Pilot

 

 

 

 

Bracket

 

 

Bend

Front Left

Bend

Front

Brackets

FP1653

Fig. 49 Burner brackets and bends.

Figure 50

Log Front Right

 

LG477

Front Brackets

20010667

25

Image 25
Contents Direct Vent Gas Fireplace Table of Contents Locating Your Fireplace Installation & Operating InstructionsDV360 DV580 Fireplace Dimensions Installed as Top VentFraming Dimensions Fireplace Dimensions Installed as Rear VentMantels Clearance to CombustiblesHearth Final Finishing Framing And FinishingGas Specifications Gas Inlet and Manifold PressuresRemote ON/OFF Switch Installation Gas Line InstallationAlternate Switch Location When purging gas line the front glass must be removedEB-1 Electrical Box Ensure that the power to the supply lineElectronic Gas Control Valve Complete conversion Optional Top Vent ApplicationLocation of Vent Termination General VentingGeneral Venting Information Termination Location Canadian Installations1 US Installations2USA Installations Canadian InstallationsGeneral Information Assembling Vent Pipes Flex Vent PipesTwist Lock Pipes How to Use the Vent GraphRear Wall Vent Application Zero clearance sleeve is only required for combustible walls Rear Wall Vent Installation Twist Lock PipeVertical Sidewall Application Rear Wall Vent Installations Flex Vent Pipe+ B = 17 Max Always install horizontal venting on a level plane Vertical Sidewall Installation Twist Lock PipeHorizontal length requirement Vertical Sidewall Installation Flex Vent PipeVertical Through-the-Roof Application Below Grade InstallationMaximum elbow usage Vertical Through-the-Roof InstallationMin 610 mm Venting Components Operating Instructions Log Identification Chart Installation of LogsDV360 Logs DV360 DV580Log Rear Refer to Figure DV580Top logs must be placed properly onto notches Flame & Temperature Adjustment Burner Lava Rock PlacementFlame Characteristics Large Lava RockDV580 DV360To Turn Off Gas To Heater Lighting and Operating InstructionsTurning Off the Gas to the Appliance Lighting InstructionsValve in the on position Transmitter Operation Off Mode Shut Off ProcedureOn Manual Mode Instructions for RF Comfort Control ValveAuto Mode Delay Timer ModeFan Override During Auto Mode Change Between F/C Temperature UnitsAuto Path LED Count Service ActionOn Path Local Path Remove Window Frame Assembly Before Service Work Troubleshooting Honeywell VS8421SIT Nova 820 Millivolt Valve Troubleshooting the Gas Control SystemStart Troubleshooting the Gas Control System Fuel Conversion Instructions Conversions must be completed by qualified personnelBurner Orifice Conversion DV360 Honeywell ValveUsing a 1/2 open end wrench remove the orifices. Fig Conversion Procedure Installation PrecautionsPilot Orifice Conversion Injector Orifice Size Matrix Cleaning the Standing Pilot Control System MaintenanceLogs May Be HOT Burner and Burner CompartmentDV360/580 DV360/580 Description DV580 GACA4P0 Fuel Conversion Kits FK12 Fan Assembly Optional AccessoriesFK24 Fan Assembly Hard Direct Wire Hook UpInstallation Instructions Remote ControlsCeramic Refractory Panels Decorative Bay WindowsArch/Square Face Kit Conversion Instructions For Use in Mobile Homes Model DV360RMH9b.Units with Honeywell valve DV360/580 Series Direct Vent Gas Fireplace Limited Lifetime Warranty AFUE% Efficiency Ratings

DV580, DV360, DV360 specifications

Vermont Castings is a name synonymous with quality and craftsmanship in the world of fireplaces. Among their celebrated products, the DV580, DV360, and DV360 stand out for their advanced technology, efficiency, and aesthetic appeal. Each of these models offers unique features designed to enhance home heating while maintaining a focus on environmental responsibility.

The DV580 is a powerful direct vent gas stove that seamlessly combines traditional aesthetics with modern functionality. With its large viewing window, it creates a cozy ambiance while allowing users to enjoy the mesmerizing flames. One of its main features is the advanced burner system, which provides a realistic flame appearance. This model also boasts an impressive BTU output, allowing it to heat larger spaces efficiently. The unit is equipped with an electronic ignition, ensuring reliable start-ups even in cold weather.

The DV360, a slightly smaller but equally efficient model, offers versatility for various home settings. With its compact design, it can fit into tighter spaces without sacrificing heating capacity. The DV360 features a unique dual burner system, which promotes a more even and consistent flame. Its direct vent technology ensures that all combustion byproducts are vented outside, maintaining indoor air quality. This model also includes an adjustable flame height, giving users control over the intensity of the heat and ambiance.

In addition to performance, both the DV580 and DV360 prioritize energy efficiency. They are designed to operate with minimal emissions, making them an environmentally friendly choice for homeowners. With a variety of finish options and customizable face designs, these models can complement any home decor. Another key characteristic is the straightforward installation process, which allows homeowners the benefit of having their unit up and running in no time.

Overall, the Vermont Castings DV580, DV360, and DV360 models exemplify a harmonious blend of innovation, functionality, and style. They not only provide warmth but also contribute to the overall aesthetic of any space. With their commitment to quality and performance, Vermont Castings continues to set the standard for direct vent gas stoves, ensuring customers enjoy the best of both worlds: comfort and beauty in their homes.