Vermont Casting DV580, DV360 Optional Accessories, Fan Kits, FK12 Fan Assembly, FK24 Fan Assembly

Page 49

DV360/580 Series Direct Vent Gas Fireplace

Optional Accessories

Fan Kits

FK12 Fan Assembly

1.Open louvre assembly bottom.

2.Install FK12 fan in back of unit between hearth sup- ports. (Fig. 79)

3.Secure fan on velcro strips.

4.Power to the fan can be supplied by plugging the supply lead into a conveniently located wall socket or by using a hard-wired EB-1 connector box.

5.Be sure fan motor does not touch hearth supports.

Side View

Cold Air Box

Front of

Unit

Hearth Pan

Base Pan

 

FK12 Fan

FP1004

Fig. 79 FK12 Fan Kit placement.

FK24 Fan Assembly

Fan specifications: 120 volt, 60 Hz, .75 Amp.

This fan does not need regular maintenance, however periodic cleaning is required. Check the area under the control door and in front of the fan and wipe or vacuum at least once a month during the operating season.

Should this fan require servicing, the power supply must be disconnected.

The FK24 comes with the electrical cord attached.

1.Slide fan assembly from the left side into the fire- place opening, line up mounting holes with screw studs on back of fireplace and fasten with #10 - 24 hex nuts. (Fig. 80)

2.Install thermal sensor on bottom of firebox using #10 - 24 hex nuts.

3.(Option A) - Place electronic fan speed control box on bottom of fireplace base, lining up mounting holes with screw studs. Fasten fan speed control box with #10 - 24 hex nuts.

(Option B) - The speed control can be installed in an electrical box at normal wall switch height for conve- nient access.

4.The power supply may be connected in 2 ways:

Method A

Route the 6’ (1.8m) lead fitted to the unit to a conve- niently located wall socket.

Method B

If the EB-1 receptacle box (Pt. #ZA1200) was cor- rectly connected when the unit was installed, the fan lead can be directly plugged into the EB-1 plug socket.

5.Whether wiring directly to the fan junction box (Op- tion A) or into the EB1 (electrical box, Option B) first ensure cable is secured using box connector.

The fireplace, when installed must be elec- trically connected and grounded in accor- dance with local codes, with the current CSA C22.1 Canadian Electrical Code or for US installations, follow local codes and the National Electrical Code, ANSI/NFPA No. 70.

Hard (Direct) Wire Hook Up

First connect ground wire to ground stud located on the base of either box. Black wire from supply should connect to the variable speed switch. Alternate speed switch wire connects to temperature sensor. Alternate lead from sensor connects to fan. Alternate fan lead connects back to the white supply wire. (Fig. 81)

Any electrical rewiring of this fan must be completed by a qualified electrician.

Turn off all power before hook up.

Electrical Box

Heat Sensor

 

 

 

 

Fan

 

 

 

F

P

 

 

 

TO

 

 

FP1026

Fan Speed

Gas Line

Valve

Switch

 

 

 

 

Fig. 80

FK24 fan placement.

 

 

 

 

Temperature

 

Fan

 

 

 

 

 

 

Sensor

 

 

 

Speed

Control

Black

White

Ground

FP1025

Fig. 81 FK24 fan wiring.

20010667

49

Image 49
Contents Direct Vent Gas Fireplace Table of Contents Locating Your Fireplace Installation & Operating InstructionsDV360 DV580 Fireplace Dimensions Installed as Top VentFraming Dimensions Fireplace Dimensions Installed as Rear VentMantels Clearance to CombustiblesHearth Final Finishing Framing And FinishingGas Specifications Gas Inlet and Manifold PressuresRemote ON/OFF Switch Installation Gas Line InstallationAlternate Switch Location When purging gas line the front glass must be removedEB-1 Electrical Box Ensure that the power to the supply lineElectronic Gas Control Valve Complete conversion Optional Top Vent ApplicationLocation of Vent Termination General VentingGeneral Venting Information Termination Location Canadian Installations1 US Installations2USA Installations Canadian InstallationsGeneral Information Assembling Vent Pipes Flex Vent PipesTwist Lock Pipes How to Use the Vent GraphRear Wall Vent Application Zero clearance sleeve is only required for combustible walls Rear Wall Vent Installation Twist Lock PipeVertical Sidewall Application Rear Wall Vent Installations Flex Vent Pipe+ B = 17 Max Always install horizontal venting on a level plane Vertical Sidewall Installation Twist Lock PipeHorizontal length requirement Vertical Sidewall Installation Flex Vent PipeVertical Through-the-Roof Application Below Grade InstallationMaximum elbow usage Vertical Through-the-Roof InstallationMin 610 mm Venting Components Operating Instructions Log Identification Chart Installation of LogsDV360 Logs DV360 DV580Log Rear Refer to Figure DV580Top logs must be placed properly onto notches Flame & Temperature Adjustment Burner Lava Rock PlacementFlame Characteristics Large Lava RockDV580 DV360To Turn Off Gas To Heater Lighting and Operating InstructionsTurning Off the Gas to the Appliance Lighting InstructionsValve in the on position Transmitter Operation Off Mode Shut Off ProcedureOn Manual Mode Instructions for RF Comfort Control ValveAuto Mode Delay Timer ModeFan Override During Auto Mode Change Between F/C Temperature UnitsAuto Path LED Count Service ActionOn Path Local Path Remove Window Frame Assembly Before Service Work Troubleshooting Honeywell VS8421SIT Nova 820 Millivolt Valve Troubleshooting the Gas Control SystemStart Troubleshooting the Gas Control System Fuel Conversion Instructions Conversions must be completed by qualified personnelBurner Orifice Conversion DV360 Honeywell ValveUsing a 1/2 open end wrench remove the orifices. Fig Conversion Procedure Installation PrecautionsPilot Orifice Conversion Injector Orifice Size Matrix Cleaning the Standing Pilot Control System MaintenanceLogs May Be HOT Burner and Burner CompartmentDV360/580 DV360/580 Description DV580 GACA4P0 Fuel Conversion Kits FK12 Fan Assembly Optional AccessoriesFK24 Fan Assembly Hard Direct Wire Hook UpInstallation Instructions Remote ControlsCeramic Refractory Panels Decorative Bay WindowsArch/Square Face Kit Conversion Instructions For Use in Mobile Homes Model DV360RMH9b.Units with Honeywell valve DV360/580 Series Direct Vent Gas Fireplace Limited Lifetime Warranty AFUE% Efficiency Ratings

DV580, DV360, DV360 specifications

Vermont Castings is a name synonymous with quality and craftsmanship in the world of fireplaces. Among their celebrated products, the DV580, DV360, and DV360 stand out for their advanced technology, efficiency, and aesthetic appeal. Each of these models offers unique features designed to enhance home heating while maintaining a focus on environmental responsibility.

The DV580 is a powerful direct vent gas stove that seamlessly combines traditional aesthetics with modern functionality. With its large viewing window, it creates a cozy ambiance while allowing users to enjoy the mesmerizing flames. One of its main features is the advanced burner system, which provides a realistic flame appearance. This model also boasts an impressive BTU output, allowing it to heat larger spaces efficiently. The unit is equipped with an electronic ignition, ensuring reliable start-ups even in cold weather.

The DV360, a slightly smaller but equally efficient model, offers versatility for various home settings. With its compact design, it can fit into tighter spaces without sacrificing heating capacity. The DV360 features a unique dual burner system, which promotes a more even and consistent flame. Its direct vent technology ensures that all combustion byproducts are vented outside, maintaining indoor air quality. This model also includes an adjustable flame height, giving users control over the intensity of the heat and ambiance.

In addition to performance, both the DV580 and DV360 prioritize energy efficiency. They are designed to operate with minimal emissions, making them an environmentally friendly choice for homeowners. With a variety of finish options and customizable face designs, these models can complement any home decor. Another key characteristic is the straightforward installation process, which allows homeowners the benefit of having their unit up and running in no time.

Overall, the Vermont Castings DV580, DV360, and DV360 models exemplify a harmonious blend of innovation, functionality, and style. They not only provide warmth but also contribute to the overall aesthetic of any space. With their commitment to quality and performance, Vermont Castings continues to set the standard for direct vent gas stoves, ensuring customers enjoy the best of both worlds: comfort and beauty in their homes.