The Century Heating G600 has been tested for a minimum 1'rise wlth a maximum 1'
horizontalrun.
This includes stove clearances and wall thickness.
The maximum horizontal run is 6'with 2' verticalrise.
To vent this unit within these dimensions pleasereferto chart figure 1.
2CMN(IMUM
WAIITTIICKNESS
4'MINIMUM
wAtrTHC(NESS
6'MINIMUM
CI.EAFANCE FROM FTAMMABI.EWALI.
FIG.1
1 2 3 4 5 6 TOTALHORIZONTALFEET
Oo Face of Erllrior Wrll Ercludlng Elboilr)
The maximumnumber of 90 degreeelbows permittedper side wall installationis one (1).
The maximumnumber of 45 degreeelbows permittedper side wall installationis one (1).
On Vertical installationstwo (2) 45'elbows areallowed.
Since it is very important that the venting system maintain its balance between the combustion air intake and the flue gas exhaust certain limitations as to vent configurations apply and must be strictly
adheredto.
The graph showing the relationshipbetween vertical and horizontal side wall venting will help to determine the various vent lengths allowable.