INSTALLATION OF LOGS
1 . Remove front glass. (See "Glass Removal" Section)
2. Remove logs from the packaging.
As with all plastics — these are not toys and should be kept away from children and infants.
3.Place rear log on rear bracket (ensure log is seated properly, leveled and centered to the unit), so it will not move from side to side and it is firmly positioned on the bracket.
4.Place front left log on top of burner, left side. Use log's bottom holes to locate it into the left bracket log locator studs.
5.Place front right log on top of burner, right side. Use log's bottom holes to locate it into the right bracket log locator studs.
6.Place ember material on top of burner. (See "Ember Material Placement" Section).
7.Place top left log onto locator notches. Ensure log is secure.
8.Place top right log onto locator notches. Ensure log is secure.
DBR33
BA5 |
| BA6 |
Log Top Left | Log Top Right | |
BA2 |
| BA4 |
| Log Rear | |
Log |
| |
|
| |
Front |
| BA3 |
Left |
| |
|
| Log Front |
|
| Right |
|
| Fig. 42 |
|
|
|
|
|
|
DBR36 | BB9 |
|
BB8 | Log Top Left | BB10 |
Log Rear |
| Log Top Right |
LOGS | DBR33 | DBR36 | DBR39 |
|
|
|
|
Front Left Log | BA2 | BB6 | BC5 |
|
|
|
|
Front Right Log | BA3 | BB7 | BC6 |
|
|
|
|
Rear Log | BA4 | BB8 | BC7 |
|
|
|
|
Top Left Log | BA5 | BB9 | BC8 |
|
|
|
|
Top Right Log | BA6 | BB10 | BC9 |
|
|
|
|
Top logs must be placed properly onto notches.
EMBER MATERIAL PLACEMENT
Separate the ember material into small pieces, roughly 1/2" in diameter and place onto the burner in front of the front logs. Do NOT pack down, leave in fluffy, loose condition for most realistic ember effect.
LAVA ROCK
The lava rock provided with this fireplace must be placed on the firebox base on either side of the burner assembly.
Under no circumstances should this lava rock be placed on any part of the burner assembly.
FLAME ADJUSTMENT
For fireplaces equipped with Hi/Lo valves, flame adjust- ment is accomplished by rotating the Hi/Lo adjustment knob located near the centre of the gas control. Fig. 46a and 46b.
BB6
BB7
Turn | Turn clockwise | |
counterclockwise | ||
to decrease | ||
to increase | ||
flame height | ||
|
Log Front Right
Log Front Left
Fig. 43
DBR39 | BC8 | BC9 |
| Log Top Left | |
| Log Top Right | |
BC7 |
| |
|
| |
Log Rear |
|
|
|
| BC6 |
|
| Log Front |
|
| Right |
BC5 |
|
|
Log Front Left |
| Fig. 44 |
|
|
|
flame height |
|
SIT 820 Valve | Fig. 46a |
Turn | Turn clockwise | |
counterclockwise | ||
to increase | ||
to decrease | ||
flame height | ||
flame height | ||
| ||
Honeywell Valve | Fig. 46b | |
| ||
|
|
- 19 -