Vermont Casting 1990 installation instructions Parallel Installations

Page 17

Intrepid II Woodburning Stove

Distance from the Center of the Flue Collar to the Wall in Top-Exit Installations

The information on this page is helpful in planning stove placement for top-exiting installations, particularly those in- stallations with chimneys that pass through the ceiling. However, this is not a clearance chart. Final stove clearances must adhere to the guidelines stated in the clearance charts on Page 14.

Intrepid II: WITHOUT Stove and Chimney Connector Heat Shields

 

Unprotected Surfaces

 

Protected Surfaces

 

 

 

 

 

 

 

 

Parallel Installations

Corner

Parallel Installations

Corner

Installations**

Installations**

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Side (A)

 

Rear (B)

Corner (C)

Side (D)

 

Rear (E)

Corner (F)

 

 

 

 

 

 

 

 

34³⁄

 

29”

26³⁄

22³⁄

 

11”

16³⁄

(883 mm)

 

(737 mm)

(680 mm)

(578 mm)

 

(279 mm)

(426 mm)

 

 

 

 

 

 

 

 

A

B

C

D

E

F

 

 

*

 

*

 

 

 

 

 

 

 

 

 

 

 

 

ST511

*This distance, from the center of the flue collar to the front edge of the hearth, is the same for all installations on this page: 31” in the United States and 33” (840mm) in Canada.

Intrepid II: WITH Stove and Chimney Connector Heat Shields

 

Unprotected Surfaces

 

Protected Surfaces

 

 

 

 

 

 

 

 

Parallel Installations

Corner

Parallel Installations

Corner

Installations**

Installations**

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Side (A)

 

Rear (B)

Corner (C)

Side (D)

 

Rear (E)

Corner (F)

 

 

 

 

 

 

 

 

34³⁄

 

15”

18³⁄

22³⁄

 

8”

16³⁄

(883 mm)

 

(381 mm)

(476 mm)

(578 mm)

 

(203 mm)

(426 mm)

 

 

 

 

 

 

 

 

A

B

C

D

E

F

 

 

 

 

 

 

ST511a

**To locate center of flue collar for corner installation, add 7” (180mm) to the clearance distance form stove corner to wall. Mark off the resulting distance from the corner along both walls. Next, measure the same distance form these two points out from the walls. These last two measure- ments will meet at a point representing the center of the flue collar. Refer to the diagrams above.

2000966

17

Image 17
Contents Intrepid Welcome Table of ContentsIntrepid II, Model SpecificationsWhat Kind of Chimney to Use InstallationOutside Air Masonry Chimneys Chimney Connector GuidelinesPrefabricated Chimneys Chimney SizeSingle-wall Chimney Connector Double-wall Chimney ConnectorSecuring the Single-wall Connector to a Masonry Chimney Freestanding Chimney InstallationsChimney connector enters chimney above the firep Fireplace Chimney Installations Above a FireplaceWall Pass-Throughs Fireplace Chimney Installations Through a FireplaceAn approved wall pass-through for Canada Floor ProtectionReducing Clearances Floor Protection for Fireplace InstallationsStove Heat Shields Chimney Connector Clearance ReductionsWall Shields Fireplace and Mantel Trim ShieldsConstruction Requirements Alcove InstallationsReflected ceiling plan Intrepid II Clearance Chart Intrepid II Clearance Diagrams 889 mm Parallel Installations Assembly Your Intrepid II’s Controls What They Do OperationAttach the Griddle Handle Glass Door Panels Damper Directs Air Flow Within the StoveAndirons Two Ways to Add FuelSurface Thermometer is a Valuable Guide to Operation Burn Only High-Quality WoodHigh-Efficiency Wood Burning With Catalytic Combustion Use the Air Control Settings that Work Best for YouHow to Build a Wood Fire Keep it Going Starting and Maintaining a Wood Fire Conditioning Your StoveAsh Disposal Refuel While the Embers are Still HotDraft Management Creosote Draft TestingFuel Back-puffingMaintenance Tighten the Damper Handle as Needed How to Adjust the Door LatchDamper Adjustment When to Suspect a Combustion System Problem Catalytic Combustion System Inspection and CleaningReplace the Stove Gaskets as Needed Replace Refractory PackageAnnual Maintenance Adjust the Door if NecessaryPermanent Gaskets Chimney System CreosoteIntrepid II Woodburning Stove Appendix Catalytic Combustor Intrepid II Woodburning Stove Intrepid II Woodburning Stove Please record the following information For future reference Intrepid II Woodburning Stove Intrepid II Woodburning Stove Warranty CFM Corporation

1990 specifications

Vermont Casting, founded in 1975, is renowned for its commitment to crafting high-quality cast iron wood stoves and heaters that merge efficiency with timeless design. By 1990, Vermont Casting had established itself as a leader in the industry, celebrated for its innovative approach to heating solutions and commitment to sustainability.

The 1990 models reflected an impressive evolution in technology and aesthetics. One of the standout features of Vermont Casting stoves was their utilization of advanced air control systems. This technology allowed users to regulate the burn speed and heat output effectively, making it easier to maintain consistent warmth in the home while optimizing fuel efficiency. The stoves featured an adjustable air inlet that provided users with the power to control combustion according to their needs.

In terms of design, Vermont Casting stoves were characterized by their iconic, rustic appearance, often featuring a choice of colors and finishes that allowed them to blend seamlessly into a variety of home aesthetics. The deep, rich finishes of the cast iron, coupled with elegant detailing, made each unit not only a heating appliance but also a centerpiece in living spaces. This commitment to aesthetics extended to the variety of designs available, including both traditional and modern styles, catering to diverse consumer preferences.

Vermont Casting also prioritized safety in their 1990 models. Many stoves were equipped with features such as double doors with glass panels, allowing users to enjoy the beauty of the flames while minimizing the risk of accidental burns. Some models incorporated heat shields that protected surrounding walls and furniture from excessive heat, further enhancing safety at home.

Durability was another hallmark of Vermont Casting’s reputation. The use of high-quality cast iron meant that these stoves were built to withstand years of use, often becoming familial heirlooms passed down through generations. In addition to resilience, cast iron was known for its ability to retain heat even after the fire had gone out, providing lingering warmth long into the night.

Overall, Vermont Casting in 1990 represented a harmonious blend of timeless design, advanced functionality, and a commitment to sustainability. Their stoves were not merely heating appliances but symbols of a lifestyle choice that emphasized quality, elegance, and environmental responsibility, making them a preferred choice for homeowners seeking both reliability and beauty in home heating solutions.