Enviro C-10794 owner manual Secondary Installation, Optional Blower Fan Installation

Page 33

Secondary Installation

INSTALLATION OF OPTIONAL BLOWER:

1.Remove the pre-assembled blower from the packaging. Inspect the blower for damage. If damage is noticed call your dealer, distributor or courier company and have components replaced.

Control panel (Fan control location)

Screw hole

Valve cover

Fan assembly

Figure 47: Optional Blower (Fan) Installation.

INSTALLATION OF LOG SET AND EMBERS:

2.Ensure the temperature sensor will touch the unit when mounted. If it does not touch, adjust the sensor so it does.

2.Place the fan assembly behind the unit and secure with the three screws provided, (as shown in Figure 47).

3.Open the gas valve cover. Carefully cut the decal portion on the control panel and install the fan control switch in this location. See Figure 46 for wiring of optional blower.

4.Plug the fan assembly into the wall outlet and turn the unit on to ensure fan operation.

The placement of the logs is not arbitrary. If they are positioned incorrectly, the flames can be “pinched” and will not burn correctly. The burner come with four (4) locator pins, and the right log has two (2) ledges which make alignment easier. Using the pictures provided, carefully set the logs in place.

NOTE: The logs are fragile and should be handled gently.

CAUTION: Use only the type of ember material supplied with this appliance. Due to the irregular size of the ember material there may be more than required. The use of other foreign materials on the burners may create dangerous conditions.

If over time, through cleaning and servicing, these embers require replacement, contact the nearest ENVIRO dealer for replacement embers.

Figure 48: Step 1 of Log Placement.

Figure 49: Step 2 of Log Placement.

33

Image 33
Contents Westport For Your SafetyGeneral Safety PrecautionsTable of Contents Codes And Approvals TOP Vent DVRear Vent DV Dimensions SpecificationsOperating Instructions For Your Safetyread Before OperatingGas valve Electronic Ignition Module Location Maintenance And ServiceHandles for Removing Door To ReplaceStep To be Installed by a Qualified Service Agency onlyConversion instructions Natural Gas Qualified Installers only Initial InstallationVenting Terminals Cannot be Recessed Into a Wall or Siding Restrictor plate settings For sufficient vent height above the roof line. For two Pipes and fittings, are Installing Vent Cap with Vinyl Siding Stand Off Corner installation rear vented with Wall Framing for Hole for Vertical OnceTwist-lock the vent cap Multi-Story Vent Pipe Installation KIT Components Installation InstructionsCut away of spacers on Flex Pipe Fire stop Assembly of Venting into a Class ‘A’ Chimney Screws removed in see Figure Turn the elbow to the rear vent position and re-fasten withInstallation for Top Vented Horizontal Termination Corner InstallationWiring Diagram InstallationA. Installations Canadian InstallationsGeneral Venting Information Venting of a Fireplace Fitted with the Drafthood AdaptorAutomatic Safety Shut Down Spill Switch ReplacementOptional Finishing To Test Valve Pressures GAS Line ConnectionWiring Diagram For Fan Control Wire Size Max. LengthOptional Blower Fan Installation Secondary InstallationComplete Log Placement Log Placement with Rock Wool Brick panel bracket, slots shown Problem Possible Cause Solution Trouble ShootingReference Number Part Description Part Number Parts List CastCast Leg Each Painted Parts Diagram Cast Reference Part Description Part Number Parts List ComponentsParts List Components Parts Diagram Components To the Dealer WarrantyInstallation Data Sheet