Enviro C-10794 owner manual Brick panel bracket, slots shown

Page 36

Secondary Installation

INSTALLATION OF PANEL SET:

Do not install when the unit is hot.

The brick panel set is fragile. Handle panels with care and avoid knocking them on the placement pins or any other object.

Figure 56: Brick panel bracket, slots shown.

1.Remove the two (2) screws from the rear of the baffle, use a 1⁄4” socket or a flat head screwdriver. Place the provided brick bracket (Figure 56) at the rear of the baffle with the slots over the screw holes (see Figure 57). Insert two (2) of the provided screws into the two (2) holes along the bottom of the baffle.

 

 

 

Figure 57: Top brick panel in place, screws shown.

Figure 58: Back brick panel in place.

Figure 59: Side brick panels in place.

2.Remove the two (2) screws from the front of the baffle. Slide the top brick panel into the bottom bracket and place the other brick bracket over the top of the panel and line up the slots on the bracket with the holes at the top of the baffle. Use two (2) of the provided screws to hold the bracket in place. Ensure the top panel is centered before tightening the four

(4) screws completely (refer to Figure 57).

3.Slide the bottom brick panel into place under/behind the top panel bracket, the notched side is to rest on the firebox bottom. The panel should rest flush with the back of the firebox (refer to Figure 58).

4.Slide each side brick panel into place along the sides of the firebox. The panels should rest flush with the back panel and the sides of the firebox (refer to Figure 59).

36

Image 36
Contents For Your Safety WestportSafety Precautions GeneralTable of Contents Codes And Approvals TOP Vent DVRear Vent DV Specifications DimensionsFor Your Safetyread Before Operating Operating InstructionsGas valve Maintenance And Service Electronic Ignition Module LocationTo Replace Handles for Removing DoorTo be Installed by a Qualified Service Agency only StepConversion instructions Natural Gas Initial Installation Qualified Installers onlyVenting Terminals Cannot be Recessed Into a Wall or Siding Restrictor plate settings For sufficient vent height above the roof line. For two Pipes and fittings, are Installing Vent Cap with Vinyl Siding Stand Off Corner installation rear vented with Once Wall Framing for Hole for VerticalTwist-lock the vent cap Multi-Story Vent Pipe Installation Installation Instructions KIT ComponentsCut away of spacers on Flex Pipe Fire stop Assembly of Venting into a Class ‘A’ Chimney Turn the elbow to the rear vent position and re-fasten with Screws removed in see FigureCorner Installation Installation for Top Vented Horizontal TerminationInstallation Wiring DiagramCanadian Installations A. InstallationsGeneral Venting Information Venting of a Fireplace Fitted with the Drafthood AdaptorAutomatic Safety Shut Down Spill Switch ReplacementOptional Finishing GAS Line Connection To Test Valve PressuresWire Size Max. Length Wiring Diagram For Fan ControlSecondary Installation Optional Blower Fan InstallationComplete Log Placement Log Placement with Rock Wool Brick panel bracket, slots shown Trouble Shooting Problem Possible Cause SolutionParts List Cast Reference Number Part Description Part NumberCast Leg Each Painted Parts Diagram Cast Parts List Components Reference Part Description Part NumberParts List Components Parts Diagram Components Warranty To the DealerInstallation Data Sheet