Enviro C-10794 owner manual Codes And Approvals, TOP Vent DV, Rear Vent DV

Page 4

Codes And Approvals

DIRECT VENT ONLY: This type is identified by the sufix DV. This appliance draws all of its air for combustion from outside the dwelling, through a specially designed vent pipe system.

TOP VENT DV

Certified for installation from 0-4500 ft (0-1372 m)

REAR VENT DV

Certified for installation from 0-4500 ft (0-1372 m) with 36” (915 mm)

 

snorkel (refer to ‘Converting Top Vented into Rear Vented’).

In the USA: The appliance may be installed at higher altitudes. Please refer to your American Gas Association guidelines which state: the sea level rated input of Gas Designed Appliances installed at elevations above 2000 (610 m) feet is to be reduced 4% for each 1000 feet (305 m) above sea level. Refer also to local authorities or codes which have jurisdiction in your area regarding the de-rate guidelines.

In Canada: When the appliance is installed at elevations above 4500 feet (1372 m), the certified high altitude rating shall be reduced at the rate of 4% for each additional 1000 feet (305 m).

This appliance has been tested by INTERTEK (Warnock Hersey) and found to comply with the established VENTED GAS FIREPLACE HEATER standards in CANADA and the USA as follows:

VENTED GAS FIREPLACE HEATER (Westport DV; NG/LPG)

TESTED TO: ANSI Z21.88a-2003/CSA 2.33a-2003 VENTED GAS FIREPLACE HEATERS

CAN/CGA 2.17-M91 GAS FIRED APPLIANCES FOR HIGH ALTITUDES

CSA P.4.1-02 TESTING METHOD FOR MEASURING ANNUAL FIREPLACE EFFICIENCY

This ENVIRO WESTPORT Fireplace:

Has been certified for use with either natural or propane gases. (See rating label.)

Is not for use with solid fuels.

Is approved for bedroom or bed sitting room. (IN CANADA: must be installed with a listed wall

thermostat. IN USA: see current ANSI Z223.1 for installation instructions.)

Must be installed in accordance with local codes. If none exist, use current

installation code CAN/CGA B149 in Canada or ANSI Z223.1/NFPA 54 in the USA.

• Must be properly connected to an approved venting system and not connected to a chimney flue serving a separate solid-fuel burning appliance.

IMPORTANT NOTICE (Regarding first fire up): When the unit is turned on for the first time, it should be turned onto high without the fan on for the first 4 hours. This will cure the paint, logs, gasket material and other products used in the manufacturing process. It is advisable to open a window or door, as the unit will start to smoke and can irritate some people. After the unit has gone through the first burn, turn the unit off including the pilot, let the unit get cold then remove the glass door and clean it with a good gas fireplace glass cleaner, available at your local ENVIRO dealer.

4

Image 4
Contents For Your Safety WestportSafety Precautions GeneralTable of Contents TOP Vent DV Codes And ApprovalsRear Vent DV Specifications DimensionsFor Your Safetyread Before Operating Operating InstructionsGas valve Maintenance And Service Electronic Ignition Module LocationTo Replace Handles for Removing DoorTo be Installed by a Qualified Service Agency only StepConversion instructions Natural Gas Initial Installation Qualified Installers onlyVenting Terminals Cannot be Recessed Into a Wall or Siding Restrictor plate settings For sufficient vent height above the roof line. For two Pipes and fittings, are Installing Vent Cap with Vinyl Siding Stand Off Corner installation rear vented with Once Wall Framing for Hole for VerticalTwist-lock the vent cap Multi-Story Vent Pipe Installation Installation Instructions KIT ComponentsCut away of spacers on Flex Pipe Fire stop Assembly of Venting into a Class ‘A’ Chimney Turn the elbow to the rear vent position and re-fasten with Screws removed in see FigureCorner Installation Installation for Top Vented Horizontal TerminationInstallation Wiring DiagramCanadian Installations A. InstallationsGeneral Venting Information Venting of a Fireplace Fitted with the Drafthood AdaptorSpill Switch Replacement Automatic Safety Shut DownOptional Finishing GAS Line Connection To Test Valve PressuresWire Size Max. Length Wiring Diagram For Fan ControlSecondary Installation Optional Blower Fan InstallationComplete Log Placement Log Placement with Rock Wool Brick panel bracket, slots shown Trouble Shooting Problem Possible Cause SolutionParts List Cast Reference Number Part Description Part NumberCast Leg Each Painted Parts Diagram Cast Parts List Components Reference Part Description Part NumberParts List Components Parts Diagram Components Warranty To the DealerInstallation Data Sheet