Enviro C-10791, 50-927 owner manual Use of Wall Straps

Page 22

Initial Installation

QUALIFIED INSTALLERS ONLY

NOTES:

(1)If an offset is necessary in the attic to avoid obstructions, it is important to support the vent pipe every 3 feet (914 mm), to avoid excessive stress on the elbows, and possible separation. Wall straps are available for this purpose (see Figure 28).

(2)When ever possible, use 45° degree elbows instead of 90° degree elbows. The 45° degree elbow offers less restriction to the flow of flue gases and intake air.

(3)For multi story installations; a ceiling firestop is required at the second floor, and any subsequent floors (see Figure 29). The opening should be framed to 10” (254 mm) x 10” (254 mm) inside dimensions, in the same manner as shown in Figure 21.

Figure 28: Use of Wall Straps.

(4)Any occupied areas above the first floor, including closets and storage spaces, which the vertical vent passes through, must be enclosed. The enclosure may be framed and sheet-rocked with standard building materials. However consult the appliance manufactures installation instructions for the minimum allowable clearance between the outside of the vent pipe, and the combustible surfaces of the enclosure. Do not fill any required air spaces with insulation.

Figure 29: Multi-Story Vent Pipe Installation.

22

Image 22
Contents For Your Safety R E C T V E N T F I R E P L a C ESafety Precautions GeneralTable of Contents Vented GAS Fireplace Heater DV36 NG/LPG Codes And ApprovalsThis Enviro DV36 Fireplace Specifications Installation OptionsFor Your Safety Read Before Operating InstructionsBlue, the fireplace is getting too much To Turn GAS Fireplace OFF Control PanelMaintenance And Service Never Operate Fireplace with the glass Removed Bottom latches for glassTo be Installed by a Qualified Service Agency only Initial Installation Qualified Installers onlyDo not interfere with the structural integrity of the walls Top of unit to bottom of 10 25.4 cm mantle Vent Termination Restrictions Venting 51mm 76mm 41 3/4 Fireplace is cool or use welder’s gloves or Possibility of a fire Horizontal Vent TerminationAssemble Vertical Vent TerminationRoof Pitch Minimum Height H Feet Meters Use of Wall Straps Installation of Electrical Wiring for the Optional FAN KIT GAS Line Connection To Test Valve PressuresSecondary Installation Empty firebox with grate and locator pinsThird Stage Log Set Installation Never operate the fireplace with the glass door removed Complete log set-up with embersTurn off the gas control knob and allow the unit to cool Is past the bottom of the baffle. Remove panel from fireboxKit Contents Installation of Kit Hook Fan Tabs Over Grommets at Unit BackTrouble Shooting Problem Possible Cause SolutionParts List Reference Part Description Part NumberParts Diagram To the Dealer WarrantyTo the Distributor Installation Data Sheet

50-927, C-10791 specifications

Enviro 50-927, also known as C-10791, represents a breakthrough in environmental technology designed to enhance sustainability and improve ecological balance. It is primarily aimed at industries with significant environmental footprints, such as manufacturing, transportation, and waste management.

At the heart of Enviro 50-927 is its advanced filtration system, which utilizes a multi-layered approach to isolate and neutralize harmful pollutants. The technology incorporates activated carbon, biofilters, and advanced polymer membranes that work synergistically to capture particulate matter, volatile organic compounds, and heavy metals. This comprehensive filtration process not only purifies air and water but also reduces the overall emissions footprint of industrial operations.

Another key feature of Enviro 50-927 is its smart monitoring technology. Equipped with IoT capabilities, it allows for real-time tracking and analytics of environmental parameters, facilitating proactive management of resources. Users can gain insights into the efficiency of operations, detect anomalies, and optimize processes, leading to reduced waste and energy consumption. This cloud-connected system enables seamless integration with existing Enterprise Resource Planning (ERP) systems, providing a holistic view of environmental impacts across operations.

Durability and resilience are significant characteristics of Enviro 50-927. Manufactured using high-grade, corrosion-resistant materials, it is designed to withstand harsh environmental conditions, making it ideal for both indoor and outdoor applications. Additionally, its compact design ensures that it can be installed in various settings without requiring extensive structural modifications.

Moreover, the installation and maintenance of Enviro 50-927 are user-friendly, requiring minimal downtime and expertise. This accessibility facilitates widespread adoption across different sectors, encouraging a shift towards sustainable practices and enhancing corporate social responsibility efforts.

In summary, Enviro 50-927, C-10791 showcases a blend of innovative technologies and user-centric design, setting a new standard for environmental management solutions. Its comprehensive features cater to evolving industry needs, promoting sustainability while maintaining operational efficiency. As companies increasingly prioritize eco-friendliness, products like Enviro 50-927 will be integral in meeting regulatory requirements and achieving sustainability goals.