Enviro 50-927, C-10791 owner manual Installation of Electrical Wiring for the Optional FAN KIT

Page 23

Initial Installation

QUALIFIED INSTALLERS ONLY

INSTALLATION OF ELECTRICAL WIRING FOR THE OPTIONAL FAN KIT:

The electric box/outlet must be hard wired to the bottom left (or right if the gas line is to come in on the left) of the unit if you plan to install the Optional Fan Kit in the future.

Refer to local electrical bylaw for proper installation. In the absence of local codes, with the current CSA C22.1 Canadian Electrical Code Part 1, Safety Standards For Electrical Installations, or The Current National Electrical Code ANSI / NFPA 70 in the US.

Figure 30. Install Electrical Outlet Into DV36.

ELECTRICAL SYSTEM FOR THERMOSTAT:

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

 

 

 

ON/OFF/Remote

 

 

 

Optional

Thermostat Switch

 

 

 

Remote

Blue

Thermocouple

70 ° F

Control

 

 

 

Thermopile

 

N

F

 

 

 

 

O

 

 

 

Inlet

F

 

 

 

O

 

Purple

 

 

 

 

 

 

 

 

Manifold

 

Pressure

 

 

 

 

Tap

 

 

 

Pressure Tap

 

 

 

 

 

 

 

Gas Control

 

 

 

Grey

Valve

 

 

 

 

 

 

 

70 ° F

 

Optional

 

 

 

 

 

Wall Switch

 

 

UP

 

 

Pilot Adjustment

 

 

DOWN

 

Screw

 

 

COOL / HEAT

 

 

 

PROGRAM

 

 

 

 

 

 

Optional

 

 

 

 

 

Thermostat

 

 

 

 

Figure 31. Wiring Diagram For Gas Valve.

Table 5. Recommended Thermostat

Wire Size.

Wire Size

Max. Length

 

 

 

14 gauge

100 ft

(30.48 m)

 

 

 

16 gauge

60 ft

(18.29 m)

 

 

 

18 gauge

40 ft

(12.00 m)

 

 

 

20 gauge

25 ft

(7.62 m)

 

 

 

22 gauge

18 ft

(5.49 m)

 

 

 

23

Image 23
Contents R E C T V E N T F I R E P L a C E For Your SafetyGeneral Safety PrecautionsTable of Contents This Enviro DV36 Fireplace Codes And ApprovalsVented GAS Fireplace Heater DV36 NG/LPG Installation Options SpecificationsOperating Instructions For Your Safety Read BeforeBlue, the fireplace is getting too much Control Panel To Turn GAS Fireplace OFFMaintenance And Service Bottom latches for glass Never Operate Fireplace with the glass RemovedTo be Installed by a Qualified Service Agency only Qualified Installers only Initial InstallationDo not interfere with the structural integrity of the walls Top of unit to bottom of 10 25.4 cm mantle Vent Termination Restrictions Venting 51mm 76mm 41 3/4 Fireplace is cool or use welder’s gloves or Horizontal Vent Termination Possibility of a fire Vertical Vent Termination AssembleRoof Pitch Minimum Height H Feet Meters Use of Wall Straps Installation of Electrical Wiring for the Optional FAN KIT To Test Valve Pressures GAS Line ConnectionEmpty firebox with grate and locator pins Secondary InstallationThird Stage Log Set Installation Complete log set-up with embers Never operate the fireplace with the glass door removedIs past the bottom of the baffle. Remove panel from firebox Turn off the gas control knob and allow the unit to coolKit Contents Hook Fan Tabs Over Grommets at Unit Back Installation of KitProblem Possible Cause Solution Trouble ShootingReference Part Description Part Number Parts ListParts Diagram To the Distributor WarrantyTo the Dealer Installation Data Sheet