Maintenance

WARNING: Disconnect power before attempting any maintenance or cleaning to re- duce the risk of fire, electrical shock or personal injury.

WARNING: Any electrical repairs or rewiring of this unit should be carried out by a licensed electrician in accor- dance with national and local codes.

WARNING: Do not exceed 60 watts per bulb when replac- ing bulbs. Use of higher-rated bulbs may result in a fire, caus- ing property damage, personal injury, or loss of life.

Replacing Light Bulbs

There are (3) colored lamps rated at 120V, 60 Watts, for use in a medium sized socket. These bulbs are located under the log bed and can be replaced as follows:

1.If you are unsure which bulb needs replacement, defective bulbs may be visually located as any of 3 bulbs colored - Red, Yellow and Orange starting from the left (see Figure 12, page 7). Defective bulbs can be replaced individually or for convenience you may want to replace all bulbs at the same time; even if only one is defective.

2.Disconnect power to unit at main breaker or fuse panel.

3.Lift log bed off hearth base to gain access to lamp fixtures. Log bed is attached with contact magnets only.

4.Remove each defective bulb from its socket and replace with appropriate color and size bulb.

Note: Be careful not to tear or damage reflec- tive ribbons. If they have come loose, they can be easily reattached or replaced at the support brackets. See Replacing Reflective Ribbons, page 21.

5.Return power to circuit and turn main power switch and lamp power on to check opera- tion of bulbs before replacing log set.

6.If all bulbs are working properly, replace the log bed over the center opening in between rear screen and front grate.

CAUTION: Make sure power is turned off at supply prior to disassembling this unit.

Maintaining Motors

Motors used on fan and heater assembly are permanently lubricated and do not require lubrication. Annual cleaning and/or vacuuming around heater and fan unit is recommended.

Removing/Replacing Control Door

The upper control door may be removed for service or replacement when necessary:

1.Open upper control door (see Figure 13, page 7).

2.Remove 4 Phillips screws from deflector shield. Angle deflector shield out of open- ing (see Figure 29).

3.Remove 4 Phillips screws from magnet assemblies.

4.Lift up on inner control door and push in each end until pivot pins are free of notches located on each side of access opening (see Figure 29).

Deflector

Control

Door

Shield

Magnet

 

Push

Assembly

Angle

Door Up

and

Door and

Back

Slide

 

Out of

 

Housing.

Figure 29 - Removing/Replacing Control

Door

115121-01B

www.desatech.com

15

Image 15
Contents Electric Fireplace OWNER’S Operation and Installation Manual Safety Information Table of ContentsProduct Specification InstallationLocating Fireplace Installation Clearances Cabinet Mantel InstallationFor mantel clearances see Figures 3 Wire Nuts BUILT-IN InstallationAccessory Cord Electric Outlet Universal Strain Relief Cord Mount AssemblyRelocating Junction Box to Left Electrical InstallationFeatures Operation Lamps and lava RockMotor Mount Foam Shipping Brace Optional Glass Doors Accessory InstallationLocating Holes Screen Rod Retaining Screw Bifold doors may be removed for replacing or cleaningOptional Brick Liners Spring Clip Locating HoleBracket Optional Heater AccessoryVE36LH Only RetainerKnockout Plug Remove to Install Power Switch Wired for convenienceMount location with on I indicator Connect white heater wire to neutralRocker Rocker Switch Red L-4 White N-1Terminal D Jumper Switch Lead Terminal L-5 Terminal Block WhiteObserved Problem Possible Cause Remedy TroubleshootingHeater Assembly Electrical Diagram Wiring DiagramRemoving/Replacing Control Door MaintenanceReplacing Light Bulbs Maintaining MotorsPanel Screws Bushings Control Power Cover HarnessesServicing Control Panel Angle control panel out through opening see FigureViewing Screen Accessing Imaging UnitBase Cover Screw Fan Assembly Posts for Blade ConnectorsServicing Fan Blower Servicing Flame PennantsLocating Flame Pennants Replacing Lamp Fixtures Reassemble imager. See AccessingRemove any loose or damaged ribbon material Cleaning Viewing ScreenAccessing Imaging Unit For Replacement Replacing Reflective RibbonsParts Not Under Warranty Technical ServiceReplacement Parts Parts Under WarrantyAccessories Illustrated Parts Breakdown Parts List 39/40 114275-01 Wire Tie 111066-01 Control Panel Decal 111066-03 Warranty Information Keep this WarrantyLimited 1 Year Warranty