MAINTENANCE
Continued
Accessing Imaging Unit
The imaging unit can be accessed from inside fireplace for servicing as follows:
1.Remove glass doors (if equipped). See Optional Glass Doors, on page 8.
2.Remove screens, grate, hearth pan brack- ets and brick liners. See Figure 33 and instructions under Optional Brick Liners, page 9.
3.Remove 4 Phillips screws holding hearth pan to fireplace and 2 screws located at lower frame rail (see Figure 34).
4.Lift rear ends of hearth pan up until front edge clears lower frame rail then slide up on end and angle out of fireplace opening.
5.Remove 4 Phillips screws holding face extensions at top refractory clips (see Figure 34).
6.Remove viewing screen from cabinet face. Viewing screen is attached by mag- nets (see Figure 35).
Note: Do not scratch viewing screen. Place on a nonabrasive surface away from work area. When replacing viewing screen painted side must face inside of cabinet with pattern facing up.
Hearth Pan | Brick Liner | |
Bracket | ||
|
Grate |
|
Refractory | Brick |
Brackets | Liner |
Hearth Pan |
|
Bracket |
|
Figure 33 - Accessing Imaging Unit
7.Remove 4 Phillips screws on base cover and lift cover off cabinet base. See Figure 36, page 18.
Note: Only VE32 series models have Face Extensions that require removal to access Imaging Unit. Model VE36 series has inner Face Panels that also require removal to ac- cess Imaging Unit.
Refractory Clip
Hearth Pan
Face Extensions
Figure 34 - Removing Hearth Pan and Face Extensions (VE32 Series Only)
Viewing Screen
Figure 35 - Removing Viewing Screen
www.desatech.com | 17 |