Avalon Stoves Indoor Fireplace 6Installation, Installation into a Factory Built Metal Fireplace

Page 16

1 6Installation

Installation into a Factory Built (Metal) Fireplace

“L” Vent

Vertical Cap

Cover Plate (non-combustible)

“L” Vent Flex Section

The smoke shelf, shields, damper, and baffles may be removed if attached with mechanical fasteners.

The firebrick (refractory) may be removed.

HINT:

Paint the interior of the fireplace with latex paint to prevent fireplace odors from entering the home.

Storm Collar

Seal the cover

 

 

plate with silicone.

 

The log grate,

 

screen (and rails),

 

and doors (if

 

present) must be

 

removed

NOTE: The fixed spacers under the appliance may not be removed.

The metal sides, frame members, or other structural components of the factory built fireplace may not be removed or altered.

The metal floor of the firebox may be removed leaving he fireplace floor outer wrap.

Use the telescoping legs to support the insert on raised fireplaces.

Travis Industries

4 0 5 0 5 2 5

1 0 0 - 0 1 1 4 4

Image 16 Contents
Astoria Bay Pellet Insert Introduction Important Information 2IntroductionTravis Industries 5 0 5 2 0 0 1 1 4 Table of Contents Safety Precautions Mobile Home 6Specifications Installation7 8Installation Hopper Extension Set-upInstallation9 Re-install the hopper walls following the directions below0Installation Installation1 Venting the Pellet Stove Mobile Home Requirements 2Installation Outside Air used for combustion Baffle Installation Restrictor Adjustment4Installation Surround Panel & Circuit Board InstallationInstallation into a Masonry Fireplace Hint6Installation Installation into a Factory Built Metal FireplaceSafety Notice Operation1Location of Controls Starting the Heater for the First TimeLoading Pellets 8OperationTwo Modes of Operation Manual Mode To Adjust the HeatTo Start To Shut DownTo Adjust Room Temperature or Start the Stove Auto Mode0Operation Adjusting the Fan Speed Operation2Maintenance Required Light 2OperationStart-Up Sequence Auger on LightUsing a Pellet/Corn Mix with This Heater Power OutagesManual Auger Button 4Maintenance Daily Maintenance whenever using the heaterInspect the Burn Make Sure Pellets are Not Piling UpCleaning the Firepot Maintenance2Check Firepot for Clinkers 6Maintenance Opening The DoorWeekly Maintenance or every 5 bags of pellets Clean the HopperClean the Heat Exchange Tubes Cleaning the Optional Plated SurfacesClean the Glass 8MaintenanceCheck Baffles, Ashbox, Ashpan, Dispose Ash If Necessary Remove the ashbox prior to conducting the service below Sweep Ash Into Ashpan0Maintenance Yearly Maintenance or every tonMaintenance3 Clean the Vent make sure the heater and vent is coolDoor Seal 2MaintenanceDoor Alignment Adjusting the Door Hinge and Latch Hinge AdjustmentReplacement Parts Check for Air Leaks Around the Door, Glass, and AshpanNormal Operating Sounds Covection FanSafety Label Serial NoLimited 7 Year Warranty Years 1 & 2 Coverage Parts & Labor8Optional Equipment ThermostatOptional Equipment ZC Kit 9 9 2 0 0 1 40Index