Avalon Stoves Indoor Fireplace manual 2Operation, Start-Up Sequence, Auger on Light

Page 22

2 2Operation

Start-Up Sequence

This stove utilizes a start-up sequence whenever the mode switch is changed or the heater is started when cold. This is to ensure proper operation through all possible settings and operational states (hot or cold, pellets burning or not burning, etc.). This sequence over-rides all user settings (except the "OFF" position) to set the auger feed rate to medium, the exhaust blower to high, and the igniter on. During this period the lowest “HEAT OUTPUT” light will flash.

"AUGER ON" Light

This light comes on when the auger is turning, allowing the operator to know when the auger is turning.

"MAINTENANCE REQUIRED" Light

N O T E: If the “MAINTENACE REQUIRED” light comes on, check the items below before calling

for service.

The “MAINTENACE REQUIRED” light is used to indicate maintenance is required on the heater. It will turn on due to various operating circumstances. When it turns on, a second light will turn on near “HEAT OUTPUT” (see the illustration to the right). Determine the maintenance code (2, 4, or 6), then use the chart below to diagnose and remedy the situation.

 

DISCONNECT POWER BEFORE SERVICE

# 6 Light

 

 

(red)

H

 

# 4 Light

E

 

HIGH

(yellow)

A

T

AUTO

 

 

# 2 Light

 

MANUAL

O

(green)

MED

U

 

 

T

AUGER

 

P

 

LOW

 

U

MAINT.

 

T(REQUIRED)

Light

Likely Cause

Remedy

 

 

 

 

2

Heavy Ash Build-Up in Exhaust Duct

Clean the Firebox (see page 30)

(green)

Heavy Ash Build-Up in Exhaust

Clean the Exhaust Housing & Tubing (see page

 

 

 

Housing or Plugged Tubing

31)

 

Heavy Ash Build-Up in Vent

Clean the Vent (see page 31)

 

 

 

 

4

Heater Ran Out of Pellets

Refill the Hopper (see page 18)

(yellow)

Heater Did Not Start-Up Correctly

Re-Start the Heater and Verify the Pellets Ignite

 

 

 

 

after 10 Minutes

 

Power Outage

Re-Start the Heater (see page 17)

 

Restrictor Not Set Properly

Re-Start the Heater and Monitor Restrictor

 

 

 

Setting (see page 21)

 

Burnpot Clogged

Clean Burnpot (see page 25)

 

Air Leak

Verify Door, Glass, and Ashpan Seal Correctly

 

 

 

(see page 32)

 

Heavy Ash Build-Up

Clean the Firebox (see page 30), Exhaust

 

 

 

Housing (see page 31), and Vent (see page 31)

 

 

 

 

6

Electrical Input Error (voltage or mhz

Unplug the Heater then Plug it Back In (this re-

(red)

 

fluctuation, amp deficiency, etc.)

starts the circuit board)

 

Components Over-Heated

Clean the Heater and Vent (a plugged heater will

 

 

 

slow exhaust flow, increasing temperatures –

 

 

 

see pages 30-31)

 

Faulty Wiring / System Fault

If this Fault Persists, Contact Your Dealer

 

 

 

 

Travis Industries

4 0 5 0 5 2 5

1 0 0 - 0 1 1 4 4

Image 22 Contents
Astoria Bay Pellet Insert Introduction Important Information 2IntroductionTravis Industries 5 0 5 2 0 0 1 1 4 Table of Contents Safety Precautions Mobile Home 6Specifications Installation7 8Installation Hopper Extension Set-upInstallation9 Re-install the hopper walls following the directions below0Installation Installation1 Venting the Pellet StoveMobile Home Requirements 2InstallationOutside Air used for combustion Baffle Installation Restrictor Adjustment4Installation Surround Panel & Circuit Board InstallationInstallation into a Masonry Fireplace Hint6Installation Installation into a Factory Built Metal FireplaceLocation of Controls Safety NoticeOperation1 Starting the Heater for the First Time Loading Pellets 8Operation Two Modes of Operation To Start Manual ModeTo Adjust the Heat To Shut DownTo Adjust Room Temperature or Start the Stove Auto Mode0Operation Adjusting the Fan Speed Operation2Start-Up Sequence Maintenance Required Light2Operation Auger on LightUsing a Pellet/Corn Mix with This Heater Power OutagesManual Auger Button Inspect the Burn 4MaintenanceDaily Maintenance whenever using the heater Make Sure Pellets are Not Piling UpCleaning the Firepot Maintenance2Check Firepot for Clinkers 6Maintenance Opening The DoorClean the Heat Exchange Tubes Weekly Maintenance or every 5 bags of pelletsClean the Hopper Cleaning the Optional Plated SurfacesClean the Glass 8MaintenanceCheck Baffles, Ashbox, Ashpan, Dispose Ash If Necessary Remove the ashbox prior to conducting the service below Sweep Ash Into Ashpan0Maintenance Yearly Maintenance or every tonMaintenance3 Clean the Vent make sure the heater and vent is coolDoor Seal 2MaintenanceDoor Alignment Adjusting the Door Hinge and Latch Hinge AdjustmentReplacement Parts Check for Air Leaks Around the Door, Glass, and AshpanNormal Operating Sounds Covection FanSafety Label Serial NoLimited 7 Year Warranty Years 1 & 2 Coverage Parts & Labor8Optional Equipment ThermostatOptional Equipment ZC Kit 9 9 2 0 0 1 40Index