FLAME APPEARANCE

Flames from the pilot, front and rear burner should be visually checked as soon as the heater is installed. In addition, periodically check the flames visually during operation.

CHECKING THE PILOT FLAME

The pilot flame must always be present when the heater is in operation. It should just touch the top of the ther- mocouple tip for natural. See Figure 31 for correct pilot flame.

If the pilot flame does not touch the thermocouple, then the main burner cannot function reliably. See Figure 32 for incor- rect shape of pilot flame.

THERMOSTAT AND MILLI-VOLT CONTROL

Thermocouple

Thermocouple

for Natural

for Natural

Thermocouple

Thermocouple

for LP

 

for LP

Figure 31 - Correct Appearance of Pilot Flame

Figure 32 - Incorrect Appearance of Pilot Flame

26

23D8036

Image 26
Contents Read and Save These Instructions Model 33ISDGWhat to do if YOU Smell GAS Contents Owner Important Safety InformationInstaller This product must be installed by a Product Features OperationPROPANE/LPG Product Features and SpecificationsNatural GAS Make Sure YOU have Received ALL Parts What YOU will Need for InstallationGetting Started Removing Screen General Installation InformationInstalling Canopy Codes Adequate Combustion and Ventilation AIRBTU/Hr = 15 1/ 2 x 12 x 1000 = 29760 BTU/Hr Before Installing the Fireplace Insert Clearances and Height RequirementsClearances and Height Requirements Minimum Clearance above Combustible Flooring Outer Wall Installation Fireplace FramingRemoving Grate and Base Assembly Securing Heater to FloorConnecting the GAS Access Holes Checking GAS Pressure Millivolt Control FigureThat does not Require 110 VAC to Operate Electrical Wiring MILLI-VOLTConnecting Optional Wall Switch or Thermostat Checking System Operation Complete Millivolt System CheckElectrical Wiring FAN WhiteLOG Placement Installing Blazing OAK Logs on BurnerInstalling Left Base Log #3 Installing Left Top Log #5 Installing Right Front Log #6 Placing Rock WoolThermostat and MILLI-VOLT Control Flame AppearanceChecking the Pilot Flame Checking the Burner Flame Operating InstructionsFor Your Safety Read Before Lighting Operating InstructionsMILLI-VOLT/THERMOSTAT Control Lighting Instructions Match Lighting Instructions Operating Instructions and Blower OperationCleaning and Servicing Troubleshooting Observed Problem Possible Cause RemedyODS/pilot lights, but flame Illustrated Parts Breakdown Replacement Parts List DIS33N/PIllustrated Parts Breakdown Replacement Parts are Available Through Your Retailer Blazing OAK Logs BOCL1823D8036 Five Year Warranty Basic Warranty