MartinLogan operating instructions Model 33ISDG, What to do if YOU Smell GAS

Page 1

VENT-FREE

FIREPLACE SYSTEMS

INSTALLATION AND

OPERATING INSTRUCTIONS

MODEL: 33ISDG

Natural Gas or Propane/LPG

Control Type: Milli-Volt and T-Stat

This appliance may be installed in an aftermarket, permanently located, manufactured (mobile) home, where not prohibited by local codes.

This applicance is for use only with the type of gas indicated on the rating plate. This applicance is not convertible for use with other gases.

This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. See page 9.

WARNINGS

If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

READ AND SAVE THESE INSTRUCTIONS

Image 1
Contents What to do if YOU Smell GAS Model 33ISDGRead and Save These Instructions Contents Installer Important Safety InformationOwner This product must be installed by a Operation Product FeaturesNatural GAS Product Features and SpecificationsPROPANE/LPG Getting Started What YOU will Need for InstallationMake Sure YOU have Received ALL Parts Installing Canopy General Installation InformationRemoving Screen Adequate Combustion and Ventilation AIR CodesBTU/Hr = 15 1/ 2 x 12 x 1000 = 29760 BTU/Hr Clearances and Height Requirements Before Installing the Fireplace InsertClearances and Height Requirements Minimum Clearance above Combustible Flooring Fireplace Framing Outer Wall InstallationSecuring Heater to Floor Removing Grate and Base AssemblyConnecting the GAS Access Holes Millivolt Control Figure Checking GAS PressureConnecting Optional Wall Switch or Thermostat Electrical Wiring MILLI-VOLTThat does not Require 110 VAC to Operate Complete Millivolt System Check Checking System OperationWhite Electrical Wiring FANInstalling Blazing OAK Logs on Burner LOG PlacementInstalling Left Base Log #3 Installing Left Top Log #5 Placing Rock Wool Installing Right Front Log #6Checking the Pilot Flame Flame AppearanceThermostat and MILLI-VOLT Control Operating Instructions Checking the Burner FlameOperating Instructions For Your Safety Read Before LightingMILLI-VOLT/THERMOSTAT Control Lighting Instructions Operating Instructions and Blower Operation Match Lighting InstructionsCleaning and Servicing Observed Problem Possible Cause Remedy TroubleshootingODS/pilot lights, but flame Illustrated Parts Breakdown DIS33N/P Replacement Parts ListIllustrated Parts Breakdown Replacement Parts are Available Through Your Retailer BOCL18 Blazing OAK Logs23D8036 Basic Warranty Five Year Warranty