VENTING

WALL TERMINATION VENTING

Before installing venting for this unit, the installer should read these instructions to insure that the proper vent confi guration has been selected.

Use only Town and Country Termination kits #: TCVT.WTA - Wall Termination Kit TCVT.RTA - Roof Termination Kit

Vent system components approved for use with the Town and Country Fireplace are shown in Figure #13.

Various combinations of vertical and horizontal runs may be used. Refer to # 17 and 18 for details. For optimum performance and fl ame appearance, keep the vent length to a minimum and limit the number of elbows. Connections between each vent system component must be tightly joined, secured with sheet metal screws and sealed. A horizontal run of vent should have a 1/4" rise for every 1 ft. of run towards the termination.

CAUTION: UNDER NO CONDITION SHOULD COMBUSTI- BLE MATERIAL BE CLOSER THAN 1 3/4 INCHES FROM THE TOP AND 1 3/4 INCHES FROM THE SIDES OF A HORIZONTAL SECTION AND 1 3/4 INCHES FROM THE VERTICAL SECTIONS OF THE VENT PIPE.

Exterior wall opening:

Determine the exact position of the fi replace so that the vent pipe is centred (if possible) between two building framing members. Consult your local building codes prior to proceed- ing. The vent kit will accommodate up to a maximum wall thickness of 12 inches.

1)Having determined the position of the fi replace, cut and frame a 14 1/2 inch opening centred at a minimum height of 68 1/2 inches above the fl oor. The opening may be round or square. Height of the opening will vary with each installation. As the horizontal vent run increases, so does the minimum vertical rise (see Fig. #17).

IMPORTANT: When locating the opening, it should be noted that vent terminal clearances must be maintained. See "Vent Terminal Clearances" section for proper clear- ances.

A minimum 2 foot length of pipe is required for any wall termi- nation. With this minimum vertical rise in combination with a 90° elbow, a maximum horizontal run of 18 inches is permitted (see Fig. #17 and 18). For longer horizontal runs greater than 18 inches, increase vertical rise appropriately.

The rise and run must be constrained to the boundaries of the chart shown in fi gure #17. The horizontal run of vent must have a 1/4" rise for every 1 ft. of run towards the termination.

Fig. # 13

 

Vent System

Town &

 

Components

Country

 

12" Pipe Length

TCVT.811X12

 

18" Pipe Length

TCVT.811X18

 

24" Pipe Length

TCVT.811X24

 

48" Pipe Length

TCVT.811X48

 

18" Adjustable Pipe Length

TCVT.811X12ADJ

 

45° Elbow

TCVT.811XLB45

 

90° Elbow

TCVT.811XLB90

 

Wall/Offset Support

TCVT.811XOS

 

Wall Termination Kit

TCVT.WTA

 

Roof Termination Kit

TCVT.RTA

 

Wall Shield/Ceiling Firestop

TCVT.THIMA

 

Roof Flashing, Adjustable

TCVT.811FLADJ

 

Roof Flashing, Flat

TCVT.811FLFLT

 

Roof Flashing, Steep

TCVT.811FLSTP

 

 

or any that fi ts 11" pipe

 

 

 

 

 

 

 

 

10 36ARB2

050505-36

Image 10
Contents Installation Operating Instructions What to do if YOU Smell GASContents Safety Fireplace DimensionsMantel Mantel Clearance ChartCeiling Mantel ClearanceTOP Standoffs Installation RequirementsLocating the Fireplace TC36.BFRKITA DimensionsSteel Stud Framing KIT Framing and FinishingInstallation Detail Concrete BoardHearth Extension Reconnect Pilot Flame indicator wiring and reinstallControl BOX Window FrameControl BOX Location Framing Detail Not OverVenting Exterior wall openingWall thimble Wall Thimble and Vent Must not Protrude Beyond SidingTrim to Length Vent pipe Wall Shield Thimble TCVT.THIMAInsulated Collar Shield Wall vent terminalWall Roof Termination Ceiling opening Roof Termination VentingVent Pipe Roof Support Bracket Ceiling firestopVent Pipe Mastic Storm Collar Vertical Termination CAPRoof vent terminal Vent Terminal Clearance Vent Terminal Minimum ClearancesVent Terminal Minimum Clearances to Adjacent Structures Insulated Collar Shield Vent Pipe SealantVent Pipe Sealant Be USED. see Section BelowRestrictor Wall and RoofTermination PositionGAS Supply Optional Wall SwitchManual Millivolt Valve Max. LengthWindow Frame Removal Herringbone Firebox Panels InstallationHerringbone Panel SET Shown Heritage REDTo Turn OFF GAS to Appliance For Your Safety Read Before LightingLighting Instructions First FireWall Thermostat Canada Only Optional GASC.THERMO HI-LO Flame AdjustmentExtend Shutdown Millivolt Pilot MaintenanceElectronic Pilot Replacement Parts DescriptionReplacement PARTS-MILLIVOLT Control Assembly Pilot Assembly NGReplacement Parts Electronic Control Assembly ELECTRONIC, Wire HarnessElectronic Valve Wiring Diagram Fig. #Wall Termination KIT Roof Termination KIT Vent Pipe Dimensions Pipe 10 1/4 16 1/4 10 15/16 22 1/4 46 1/4Pipe 23 1/4 27 5/8 PipeGastitetm Flex Line with Reducing Coupling Flexible Connector With Shutoff ValveVarious GAS Supply Connections Black Iron Pipe with UnionEN Case D’EMPLOI Avec Safety Label LocationFor USE with Natural GAS LP GAS Made in CanadaAllenby Rd., Duncan, BC V9L Phone