Vent pipe:
Install vent pipe through the wall thimble and attach to fl ue outlet collar on top of the fireplace. Secure all joints with screws and seal with approved "High Temp."
The fireplace position may need to be adjusted to ensure that the vent pipe does not protrude beyond the outer wall or be recessed any more than 12 inches with the inner pipe.
Fig. #16
WALL SHIELD
THIMBLE
TCVT.THIMA
Wall vent terminal:
1)Engage the 8" vent collar with the vent pipe and slide terminal into place. Attach the terminal to the outside wall. The vent terminal must not be recessed into the exterior wall or siding.
2)Caulk in place to prevent any moisture entering the build- ing.
NOTE: MINIMUM CLEARANCES TO THE VENT TERMINAL MUST BE MAINTAINED (see Fig. #17).
14 1/2" FRAMED OPENING
ELBOW
TCVT.811XLB90 | HORIZONTAL | |
TERMINAL | ||
| ||
24" VENT PIPE | TCVT.9360 | |
| ||
TCVT.811X24 |
|
INSULATED
COLLAR
SHIELD
TC36.9709
12" VENT PIPE | * |
TCVT.811X12 |
|
* Minimum height from the floor to center of the opening with a maximum horizontal run of 18" using TC Vent. The height will need to be increased with a longer horizontal run .
12 36ARB2 |