COMBUSTIBLE FRAMING AND
FINISH WALL ABOVE STANDOFFS
MAY USE COMBUSTIBLE FACING
MATERIAL IN THIS AREA
FINISH MATERIAL
SEE FIG #7
D
E
AF
B
C
TOP OF LINTEL BAR
FIREPLACE FRONT
Fig. # 2
STEEL FRAMING
STANDOFFS
DO NOT INSTALL ANY
COMBUSTIBLE MATERIAL,
ELECTRICAL WIRING OR
GAS PLUMBING IN THIS
AREA.
MANTEL CLEARANCE CHART
REF. | MANTEL | REF. | |
*CLEARANCE | |||
|
| ||
A | 9" | D | |
B | 6" | E | |
C | 3" | F |
**DEPTH 12"MANTEL
63/4"
1 1/2"
Minimum Clearances to Combustibles:
Side standoffs | 0 in. | (0 mm) |
Back standoffs | 0 in. | (0 mm) |
Top standoffs | 0 in. | (0 mm) |
Bottom of appliance | 0 in. | (0 mm) |
Adjacent sidewall | 4 in. | (102 mm) |
Ceiling to appliance | 24 in. | (610 mm) |
*Mantel to appliance | See Figure #2 | |
**Maximum |
|
|
Mantel extension | See Figure #2 | |
Mantel support | 4 in. | (102 mm) |
Vertical vent pipe | (45 mm) | |
Horizontal vent pipe |
|
|
Top | (45 mm) | |
Sides | (45 mm) | |
Bottom | (45 mm) |
Fig. # 3
CEILING
MANTEL | ADJACENT |
| |
| WALL OR |
| MANTEL |
| SUPPORT |
UNIT MAY BE RECESSED UP TO 6" WITH
4 36ARB2 |