CAUTION

FOR YOUR SAFETY - Do not install or operate your Town and Country fi replace without fi rst reading and understanding this manual. Any installation or operational deviation from the following instructions voids the Town and Country FireplacesTM Warranty and may prove hazardous.

This appliance and its individual shutoff valve must be discon- nected from gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).

This appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).

Note: When lit for the fi rst time, the appliance will emit a slight odour for a couple of hours. This is due to the curing of paints, sealants and lubricants used in the manufacturing process. This condition is temporary. Open doors and windows to ventilate area. Smoke and fumes caused by the curing process may cause discomfort to some individuals.

Do not use the fi replace if any part has been under water. Immediately call a qualifi ed service technician to inspect the fi replace and to replace any part of the control system and any gas control which has been under water.

Fig # 1

SAFETY

Due to high temperatures, this gas appliance should be located out of traffic and away from furniture and draperies.

Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.

Young children should be carefully supervised when they are in the same room as the appliance.

Clothing or other flammable material should not be placed on or near the appliance.

Any grill, panel or door removed for servicing the unit must be replaced prior to operating. Failure to do so may create a hazardous condition.

Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean.

It is our policy that no responsibility is assumed by the Company or by any of its employees or representatives for any damages caused by an inoperable, inadequate, or unsafe condition which is the result, either directly or indirectly, of any improper operation or installation procedures.

FIREPLACE DIMENSIONS

CENTER OF

FLUE OUTLET

TOP

STANDOFFS

050505-36

36ARB2 3

Image 3
Contents What to do if YOU Smell GAS Installation Operating InstructionsContents Fireplace Dimensions SafetyMantel Clearance Mantel Clearance ChartCeiling MantelInstallation Requirements TOP StandoffsLocating the Fireplace Framing and Finishing DimensionsSteel Stud Framing KIT TC36.BFRKITAConcrete Board Installation DetailWindow Frame Reconnect Pilot Flame indicator wiring and reinstallControl BOX Hearth ExtensionNot Over Control BOX Location Framing DetailExterior wall opening VentingWall Thimble and Vent Must not Protrude Beyond Siding Wall thimbleTrim to Length Wall vent terminal Wall Shield Thimble TCVT.THIMAInsulated Collar Shield Vent pipeWall Roof Termination Ceiling firestop Roof Termination VentingVent Pipe Roof Support Bracket Ceiling openingVertical Termination CAP Vent Pipe Mastic Storm CollarRoof vent terminal Vent Terminal Minimum Clearances Vent Terminal ClearanceVent Terminal Minimum Clearances to Adjacent Structures Be USED. see Section Below Vent Pipe SealantVent Pipe Sealant Insulated Collar ShieldPosition Wall and RoofTermination RestrictorMax. Length Optional Wall SwitchManual Millivolt Valve GAS SupplyWindow Frame Removal Heritage RED Firebox Panels InstallationHerringbone Panel SET Shown HerringboneFirst Fire For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS to ApplianceHI-LO Flame Adjustment Wall Thermostat Canada Only Optional GASC.THERMOExtend Shutdown Maintenance Millivolt PilotElectronic Pilot Description Replacement PartsPilot Assembly NG Replacement PARTS-MILLIVOLT Control AssemblyELECTRONIC, Wire Harness Replacement Parts Electronic Control AssemblyFig. # Electronic Valve Wiring DiagramWall Termination KIT Roof Termination KIT Pipe 10 1/4 16 1/4 10 15/16 22 1/4 46 1/4 Vent Pipe DimensionsPipe Pipe 23 1/4 27 5/8Black Iron Pipe with Union Flexible Connector With Shutoff ValveVarious GAS Supply Connections Gastitetm Flex Line with Reducing CouplingMade in Canada Safety Label LocationFor USE with Natural GAS LP GAS EN Case D’EMPLOI AvecAllenby Rd., Duncan, BC V9L Phone