1) HI-LO Flame Adjustment:

The HI-LO burner control knob can be rotated in both direc- tions, providing infi nite control of gas fl ow rate to the burner and therefore greater comfort control. The HI setting provides a maximum gas input, and rotating the knob clockwise toward the LO setting will reduce the gas input to a minimum setting.

2)Wall Thermostat - Canada Only - (Optional part # GASC.THERMO):

Set the wall thermostat to a comfortable temperature. Turn the HI-LO burner control knob to a desired setting. As heat is required, the fi replace will turn on or off automatically.

Extend Shutdown:

Manual Valve: To shutdown the appliance including the pilot, partially depress and turn gas control knob clockwise past “PILOT” to “OFF” position. DO NOT FORCE.

NOTE: The SIT control has an interlock device which does not allow the pilot to be lit when the appliance is at operating temperature. Let the appliance cool down (approx. 60 sec.) before attempting to relight the pilot. DO NOT use force to rotate the control knob.

Electronic Valve: Push the "Burner" switch to the "Off" posi- tion. Turn off all electric power to the appliance and remove backup batteries if service is to be performed or for extended shutdown.

Fig. # 33

HI-LO Control Knob

BURNER CONTROL

LIGHTING INSTRUCTIONS - Electronic Valve

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance is equipped with an ignition device which auto- matically lights the pilot. Do not try to light the pilot by hand.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

-Do not try to light any appliance.

-Do not touch any electric switch; do not use any phone in your

building.

-Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions.

-If you cannot reach your gas supplier, call the fire depart- ment.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance & to replace any part of the control system & any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above on this label.

2.Set wall thermostat to lowest setting, if applicable.

3.This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.

4.Push the "Burner" switch to the "Off" position.

5.Allow sufficient length of time (minimum 5 minutes) for any gas in the combustion chamber to escape. If you still smell gas, STOP! Follow "B" in the safety information above on this label. If you don't smell gas, go to the next step.

6.Push the "Burner" switch back to the "On" position.

-If the burner does not light, repeat steps 4 through 6.

-If the burner will not light or stay lit after several tries, turn the "Burner" switch to the "Off" position and call your service technician or gas supplier.

Note: Sufficient time must be allowed for air to escape from lines if the unit is being lit for the first time.

7.Turn HI-LO burner control knob to desired setting and close control door.

8.Set thermostat to desired setting, if applicable.

TO TURN OFF GAS TO APPLIANCE

1.Set wall thermostat to lowest setting, if applicable.

2.Push the "burner" switch to the "Off" position.

3.Turn off all electric power to the appliance and remove backup batteries if service is to be performed or for extended shutdown.

Due to high surface temperatures, keep children, clothing and furniture away. Keep burner and control compartment clean. See installation and operating instructions accompanying the appliance.

A cause de la temperature elevee des parios, tenir eloignes les enfants, les vetements et les meubles. Maintenir propres le bruleur et le compartiment de commande. Voir les instructions relatives a l'installation et au fonctionnement qui accompagnent l'appareil.

24 36ARB2

050505-36

Image 24
Contents Installation Operating Instructions What to do if YOU Smell GASContents Safety Fireplace DimensionsMantel Clearance Chart CeilingMantel Mantel ClearanceInstallation Requirements TOP StandoffsLocating the Fireplace Dimensions Steel Stud Framing KITTC36.BFRKITA Framing and FinishingInstallation Detail Concrete BoardReconnect Pilot Flame indicator wiring and reinstall Control BOXHearth Extension Window FrameControl BOX Location Framing Detail Not OverVenting Exterior wall openingWall Thimble and Vent Must not Protrude Beyond Siding Wall thimbleTrim to Length Wall Shield Thimble TCVT.THIMA Insulated Collar ShieldVent pipe Wall vent terminalWall Roof Termination Roof Termination Venting Vent Pipe Roof Support BracketCeiling opening Ceiling firestopVertical Termination CAP Vent Pipe Mastic Storm CollarRoof vent terminal Vent Terminal Minimum Clearances Vent Terminal ClearanceVent Terminal Minimum Clearances to Adjacent Structures Vent Pipe Sealant Vent Pipe SealantInsulated Collar Shield Be USED. see Section BelowWall and Roof TerminationRestrictor PositionOptional Wall Switch Manual Millivolt ValveGAS Supply Max. LengthWindow Frame Removal Firebox Panels Installation Herringbone Panel SET ShownHerringbone Heritage REDFor Your Safety Read Before Lighting Lighting InstructionsTo Turn OFF GAS to Appliance First FireHI-LO Flame Adjustment Wall Thermostat Canada Only Optional GASC.THERMOExtend Shutdown Maintenance Millivolt PilotElectronic Pilot Replacement Parts DescriptionReplacement PARTS-MILLIVOLT Control Assembly Pilot Assembly NGReplacement Parts Electronic Control Assembly ELECTRONIC, Wire HarnessElectronic Valve Wiring Diagram Fig. #Wall Termination KIT Roof Termination KIT Vent Pipe Dimensions Pipe 10 1/4 16 1/4 10 15/16 22 1/4 46 1/4Pipe 23 1/4 27 5/8 PipeFlexible Connector With Shutoff Valve Various GAS Supply ConnectionsGastitetm Flex Line with Reducing Coupling Black Iron Pipe with UnionSafety Label Location For USE with Natural GAS LP GASEN Case D’EMPLOI Avec Made in CanadaAllenby Rd., Duncan, BC V9L Phone