SAFETY LABEL
This is a copy of the label that accompanies each ULTIMATE Rear Vent Direct Vent Free- standing Gas Stove. We have printed a copy of
the contents here for your review. The safety label is located on the inside of the drop down pedestal door.
NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
Copy of Safety Label for U37
Listed: GRAVITY DIRECT VENT WALL FURNACE
Certified for/Certifiée pour: CANADA AND U.S.A.
Tested to: CGA
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE
Serial No./No de serie
221
DO NOT REMOVE THIS LABEL /
NE PAS ENLEVER CETTE ÉTIQUETTE
|
|
| FACTORY EQUIPPED FOR NATURAL GAS: Model | ||||||
|
|
| |||||||
| Model/Modele: | Min. supply pressure | 5.0" | WC/C.E. (1.24Kpa) | Pression d’alimentation minimum | ||||
| |||||||||
| Manifold | pressure | High 3.8" | WC/C.E. (0.947Kpa) Pression à la tubulure d’échappement élevée | |||||
| Manifold | pressure | Low 1.1" | WC/C.E. (0.27Kpa) | Pression à la tubulure d’échappement élevée | ||||
|
|
| |||||||
|
|
| Orifice size |
| #37 | DMS |
| Dimensions de l’orifice | |
|
|
|
|
| |||||
|
|
| Altitude |
|
|
| ft/pi |
| L’altitude |
|
|
|
|
| |||||
|
|
| Maximum | Input |
| 30,000 | Btu/h | (8.79Kw/h) Débit calorifique maximum selon | |
|
|
| Minimum | Input |
| 15,000 | Btu/h | (4.39Kw/h) Débit calorifique minimum selon | |
|
|
|
| ||||||
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
| FACTORY EQUIPPED FOR PROPANE: Model | ÉQUIPÉ À L'UISINE POUR GAZ PROPANE: | |||||
|
|
| Min. supply pressure | 12" | WC/C.E. (3.00Kpa) | Pression d’alimentation minimum | |||
|
|
| |||||||
| Model/Modele: | Manifold | pressure | High 11" | WC/C.E. (2.74Kpa) | Pression à la tubulure d’échappement élevée | |||
| |||||||||
| Manifold | pressure | Low 2.9" | WC/C.E. (0.72Kpa) | Pression à la tubulure d’échappement élevée | ||||
|
|
| |||||||
|
|
| Orifice size |
| #52 | DMS |
| Dimensions de l’orifice | |
|
|
| Altitude |
|
| ft/pi | L’altitude | ||
|
|
|
|
| |||||
|
|
| Maximum | Input |
| 30,000 | Btu/h | (8.79Kw/h) Débit calorifique maximum selon | |
|
|
|
| ||||||
|
|
|
| ||||||
|
|
| Minimum | Input |
| 15,000 | Btu/h | (4.39Kw/h) Débit calorifique minimum selon | |
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
VENTING: Only for direct discharge without duct connection. This appliance must be installed in accordance with the manufacturer's installation instructions and with local codes, if any; if not, follow the current ANSI Z223.1 in the USA or the current
Electrical supply 115VAC, 1.13 A, 60 Hz. Not for use with solid fuel.
FPI Fireplace Products International Ltd., Delta, BC, Canada MADE IN CANADA / FABRIQUE AU CANADA
| DOOR SEAL ADJUSTMENT: |
|
| Please check that door is properly sealed. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Periodic adjustment of latch may be required. | ||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Minimum
Clearances to Combustibles/ Degagement Minimum Des Materiaux Combustibles
Min. Ceiling
Height from top
of unit / Min.
Plafond Hauteur
en haut de l'appareil:
36" / 914 mm
For the State of Massachusetts, installation and repair must be done by a plumber or gasfitter licensed in the Commonwealth of Massachusetts.
For the State of Massachusetts, flexible connectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appli- ances individual manual
4 | U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater |