INSTALLATION
RESIDENTIAL AND MANUFACTURED HOMES/
MOBILE HOMES INSTALLATIONS
You will require the following components with your new Regency Rear Vent Direct Vent Freestanding Gas Stove. Please review your product to make sure you have everything you need. In the event that you are missing any part, contact your dealer. Decorative brass or chrome trim kits are available from Simpson
Note: These are the minimum pieces required.
Other parts may be required for your particular installation.
Minimum components for a Horizontal Installation:
Horizontal Termination Kit which includes: | |||
| 1 | ||
| 1 | 4" Dia. x 18" Aluminum Vent | |
| 1 | Riser Vent Terminal | |
| 1 | Wall Penetration Heat Shield (Wall Thimble) (2 pcs) | |
| 1 | Decorative Wall Trim (Black) | |
| 1 | Tube | |
|
|
| Screws |
Optional Components: |
| ||
| 45o Elbow - | ||
|
| Aluminum Vent | |
| Vinyl Siding Shield for Riser Vent | ||
|
| Terminal |
|
| Vent Guard |
| |
940 |
| Square Wall Thimble Cover* |
981Snorkel Termination (36")*
982Snorkel Termination (14")*
942 | Wall Penetration |
| Heat Shield* |
* Simpson
Alternate Snorkel
Termination Cap
Part # 982 (14")
Part # 981 (36")
HORIZONTAL INSTALLATIONS
1)Set the unit in its desired location. Check to determine if wall studs are in the way when the venting system is attached. If this is the case, you may want to adjust the location of the unit.
2)Assemble the desired combination of pipe and elbow to the appliance adapter with pipe seams oriented down. Offset the pipe seams as double seams in one place will cause the outer pipe to take an oval shape. Kit comes complete with 18" of straight vent -
3)With the pipe attached to the stove, slide the stove into its correct location, and mark the wall for a
Diagram 1
Note:
a)The horizontal run of vent should have a 1/4 inch rise for every 1 foot of run towards the termination. Never allow the vent to run downward. This could cause high temperatures and may present the possibility of a fire.
b)The location of the horizontal vent ter- mination on an exterior wall must meet all local and national building codes, and must not be blocked or obstructed. For External Vent Terminal Locations, see diagram on page 7.
c)Snorkel Terminations:
For installations requiring a vertical rise on the exterior of the building,
Diagram 2a
*Dia 2a & 2b: As specified in CGA B149 Instal- lation Code. Local codes or regulations may require different clearances.
U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater | 11 |