Regency U37-LP PROPANE Straight Vertical Terminations, Offset to Vertical Terminations

Page 10

INSTALLATION

RIGID PIPE VENTING - VERTICAL TERMINATIONS

FOR BOTH RESIDENTIAL & MANUFACTURED HOMES/MOBILE HOMES

Vertical Terminations

Vertical Terminations

with Co-linear Flex System

using Rigid Piping Systems

The shaded area in the diagram shows the allowable vertical terminations installed in a masonry chimney. All vertical vent installations require the Vent Restrictor to be set to 1-1/4" (32mm) open.

Straight Vertical Terminations

The shaded areas in the two diagrams below show all allowable combinations of straight vertical and offset to vertical runs with vertical terminations. Maximum one 90o elbow. All vertical and offset to vertical vent installations require Vent Restrictor to be set to 1-1/4" (32mm) open. If the vent is ENCLOSED in a chase (min. size 9" x 9") maintain a 1-1/4" (32mm) clearance to combustibles.

Offset to Vertical Terminations

WARNING:

Do not combine venting components from different venting systems.

However use of the the AstroCapTM and FPI

Riser is acceptable with all systems.

This product has been evaluated by Intertek for using a Dura-Vent Flue Adaptor in conjunction with Selkirk Direct-Temp and Ameri Vent Direct venting systems. Use of these systems with the Direct Vent GS starting collar is deemed acceptable and does not affect the Intertek WHI listing of components.

When using piping other than Simpson Dura-Vent, 3 screws must be used to secure rigid pipe to adaptor.

The FPI AstroCapTM and FPI Riser Vent terminal is certified for installations using FPI venting systems as well as Simpson Dura-Vent®, Direct Vent GS, American Metal Products, Ameri Vent Direct vent and Selkirk Direct-Temp. FPITM, and FPI Astro- CapTM are the proprietary trademarks of FPI Fire- place Products International Ltd. Dura-Vent® and Direct Vent GS are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.

If using a Rigid Pipe Venting Sys- tem a rigid pipe adaptor #640-994 is required.

Rigid Pipe

Vent Restrictor Position

Adapter

 

To set the Vent restriction

 

as indicated in the diagram,

 

simply loosen the screws

 

and push the vent restrictor

 

plate to the correct position.

 

Tighten the screws.

10

U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater

Image 10
Contents Installation Manual Regency To the New OwnerTable of Contents Dimensions de l’orifice Safety LabelCopy of Safety Label for U37 Serial No./No de serie 221General Safety Information InstallationSpecifications Save These InstructionsManufactured Mobile Home Additional Requirements Checklist Combustibles Locating Your Ultimate GAS StoveClearances to Combustion and Ventilation AIRAir supply outlet Planning Your Venting Installation Venting Installation PrecautionsSafety Precautions for Installer See page 7 for Exterior Vent Termination requirementsRigid Pipe Venting Components List 4DT-AJBOffset to Vertical Terminations Straight Vertical TerminationsVent Restrictor Position Alternate Snorkel Termination Cap Horizontal InstallationsOptional Components Snorkel TerminationsHint Apply sealant to female end Required Parts Description Vertical Termination with CO-LINEAR Flex SystemAlternate Approved Caps General Converting a Factory Built Metal ChimneyConverting a Masonry Chimney Conversion Kit from Natural Gas to Propane GAS Connection Aeration AdjustmentLOG SET Installation High ElevationA02-65 GAS Pipe Pressure Testing Valve DescriptionControl Optional RemoteFinal Check Wiring Diagram Operating Instructions Clean. See installation Temperatures keep children, clothingCopy of the Lighting Plate Instructions Maintenance Installing Glass Latch AdjustmentGlass Replacement Never operate your unit with bro- ken glassBefore removing the valve FAN MaintenanceRemoving Valve To remove fanMaintenance Parts List U37 Main AssemblyU37 Burner & LOG Assembly U37 Door Assemblies Warranty ConditionsInstaller Please complete the following information