Regency U37-NG NATURAL GAS, U37-LP PROPANE installation manual Air supply outlet

Page 7

U37 Regency ULTIMATE Rear Vent Direct Vent

Vertical Termination

24"

D

E

V

Inside corner detail

G

V

A

Vertical

Termination

24"

18"

V

Freestanding Gas Heater

B

V

M

.

C

 

V

Fixed

 

 

Closed

F

V

Openable

 

B

V

Openable

B

Fixed Closed

 

H

V

 

B

N

 

L

B

B

V

K

A

 

j

 

 

 

A

 

V

A

V

Vent terminal

A

Air supply outlet

 

Area where terminal is not permited

 

 

 

 

7

A= Clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm)

H= Not to be installed above a meter/regulator assembly within

B= Clearance to window or door that may be opened *(12"/30cm) #(9"/23cm)

 

(3'/90cm) horizontally from the centerline of the regulator.

C= Clearance to permanently closed window *(min. 12"/30cm)

J=

Clearance to service regulator vent outlet *(min. 36"/90cm)

D= Vertical clearance to ventilated soffit located above the terminal within a horizontal

K=

Clearance to non-mechanical air supply inlet to building

 

distance of (24"/60cm) from the centerline of the terminal (min. 22"/55cm) check with

 

or the combustion air inlet to any other appliance *(12"/30cm) #(9"/23cm)

 

local code.

L=

Clearance to a mechanical air supply inlet *(min. 72"/1.8m)

E=

Clearance to unventilated soffit (min. 12"/30cm)

 

#3' (91cm) above if within 10' (3m) horizontally.

F=

Clearance to outside corner (12"/30cm)

M= **Clearance above paved sidewalk or a paved driveway located

G= Clearance to inside corner (12"/30cm)

 

on public property *(min. 84"/2.1m)

 

 

N= Clearance under veranda, porch, deck, or balcony *(min.

 

 

 

12"/30cm)***

 

Note: * As specified in CGA B149 Installation Code. Note: Local codes or

regulations may require different clearances.

 

**A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings.

 

***Only permitted if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.

 

# In accordance with the current ANSI Z223.1/NFPA 54, National Gas Code

 

Image 7
Contents Installation Manual To the New Owner RegencyTable of Contents Serial No./No de serie 221 Safety LabelCopy of Safety Label for U37 Dimensions de l’orificeSave These Instructions InstallationSpecifications General Safety InformationCombustion and Ventilation AIR Checklist Combustibles Locating Your Ultimate GAS StoveClearances to Manufactured Mobile Home Additional RequirementsAir supply outlet See page 7 for Exterior Vent Termination requirements Venting Installation PrecautionsSafety Precautions for Installer Planning Your Venting Installation4DT-AJB Rigid Pipe Venting Components ListOffset to Vertical Terminations Straight Vertical TerminationsVent Restrictor Position Snorkel Terminations Horizontal InstallationsOptional Components Alternate Snorkel Termination CapHint Apply sealant to female end Required Parts Description Vertical Termination with CO-LINEAR Flex SystemAlternate Approved Caps Converting a Factory Built Metal Chimney GeneralConverting a Masonry Chimney Conversion Kit from Natural Gas to Propane High Elevation Aeration AdjustmentLOG SET Installation GAS ConnectionA02-65 Valve Description GAS Pipe Pressure TestingControl Optional RemoteFinal Check Wiring Diagram Operating Instructions Clean. See installation Temperatures keep children, clothingCopy of the Lighting Plate Instructions Maintenance Never operate your unit with bro- ken glass Latch AdjustmentGlass Replacement Installing GlassTo remove fan FAN MaintenanceRemoving Valve Before removing the valveMaintenance U37 Main Assembly Parts ListU37 Burner & LOG Assembly U37 Door Assemblies Conditions WarrantyInstaller Please complete the following information