Regency U37-NG NATURAL GAS, U37-LP PROPANE Installation, Save These Instructions, Specifications

Page 5

INSTALLATION

IMPORTANT:

SAVE THESE

INSTRUCTIONS

The ULTIMATE Rear Vent Direct Vent Free- standing Gas Stove must be installed in accord- ance with these instructions. Carefully read all the instructions in this manual first. Consult the building authority having jurisdiction to deter- mine the need for a permit prior to starting the installation.

Note: Failure to follow the instructions could cause a malfunction of the heater which could result in death, serious bodily injury, and/or prop- erty damage. Failure to follow these instructions may also void your fire insurance and/or warranty.

SPECIFICATIONS

Fuels: U37-NG is approved for use with natural gas.

U37-LP is approved for use with liquefied petroleum gases (propane).

Electrical: 120 V A.C. system.

Circulation Fan: Variable speed, 125/75.

Log Sets: Ceramic fibre, 7 per set.

Vent System:

Axial (6-5/8" outer / 4" inner liner) rigid flue and Riser Vent Terminal.

BEFORE YOU START

Safe installation and operation of this appliance requires common sense, however, we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following:

INSTALLATION AND REPAIRS SHOULD BE DONE BY A QUALI- FIED SERVICE PERSON. THIS AP- PLIANCESHOULDBEINSTALLED, REPAIRED, INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A QUALIFIED SERVICE PER- SON. MORE FREQUENT CLEAN- ING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPET- ING, ETC. IT IS IMPERATIVE THAT THE CONTROL COMPARTMENT, BURNERSANDCIRCULATINGAIR PASSAGEWAYS OF THE APPLI- ANCE BE KEPT CLEAN.

DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LO- CATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.

WARNING: FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILLVOIDYOURWARRANTYAND MAY CAUSE A SERIOUS HOUSE FIRE.

CHILDREN AND ADULTS SHOULD BEALERTEDTOTHEHAZARDSOF HIGHSURFACETEMPERATURES, ESPECIALLY THE FIREPLACE GLASS,ANDSHOULDSTAYAWAY TO AVOID BURNS OR CLOTHING IGNITION.

YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THEAPPLIANCE.

CLOTHING OR OTHER FLAMMA- BLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLI- ANCE.

1)Provide adequate clearances for servic- ing, proper operation and around the air openings into the combustion chamber.

2)The appliance must be installed on a flat, solid, continuous surface (e.g. wood, met- al, concrete). This may be the floor, or it can be raised up on a platform to enhance its visual impact. The appliance may be in- stalled on carpeting, tile, wood flooring or other combustible material, because the appliance's metal pedestal base extends the full width and depth of the appliance. The ULTIMATE Rear Vent Direct Vent Free- standing Gas Stove can be installed in a wide variety of ways and will fit nearly any room layout. It may be installed in a re- cessed position, framed out into the room, or across a corner.

3)The ULTIMATE Rear Vent Direct Vent Free- standing Gas Stove is approved for manu- factured home installations, see pages 6 to 9 for the required vent arrangements. If installed into a manufactured home the unit must be bolted down to the floor.

4)We recommend that you plan your installa- tion on paper using exact measurements for clearances and floor protection before actually installing this appliance. Have a qualified building inspector review your plans before installation.

GENERAL SAFETY

INFORMATION

1)The appliance installation must conform with local Canadian Electrical Code.

2)The appliance when installed, must be elec- trically grounded in accordance with local codes, or in the absence of local codes with the current National Electrical Code, ANSI/ NFPA 70 or CSA C22.1 Canadian Electrical Code.

3)The appliance should be inspected for shipping damage before use and serviced annually by a professional service per- son. More frequent cleaning may be re- quired due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, and circulating air passageways of the appliance be kept clean and free from excessive lint from carpeting.

4)See general construction and assembly instructions. The appliance and vent should be enclosed when installed in or passing through a living area, where children may come in contact with it.

5)This appliance must be connected to the specified vent and termination cap to the outside of the building envelope. Never vent to another room or inside a building. Make sure that the vent is fitted as per the instruc- tions starting on page 6.

6)Inspect the venting system annually for blockage and any signs of deterioration.

7)Venting terminals shall not be recessed into a wall or siding.

8)Any safety glass removed for servicing must be replaced prior to operating the appliance.

9)To prevent injury, do not allow anyone who is unfamiliar with the operation to use the fireplace.

Emissions from burning wood or gas could contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.

U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater

5

Image 5
Contents Installation Manual To the New Owner RegencyTable of Contents Copy of Safety Label for U37 Safety LabelDimensions de l’orifice Serial No./No de serie 221Specifications InstallationGeneral Safety Information Save These InstructionsClearances to Checklist Combustibles Locating Your Ultimate GAS StoveManufactured Mobile Home Additional Requirements Combustion and Ventilation AIRAir supply outlet Safety Precautions for Installer Venting Installation PrecautionsPlanning Your Venting Installation See page 7 for Exterior Vent Termination requirements4DT-AJB Rigid Pipe Venting Components ListVent Restrictor Position Straight Vertical TerminationsOffset to Vertical Terminations Optional Components Horizontal InstallationsAlternate Snorkel Termination Cap Snorkel TerminationsHint Apply sealant to female end Alternate Approved Caps Vertical Termination with CO-LINEAR Flex SystemRequired Parts Description Converting a Factory Built Metal Chimney GeneralConverting a Masonry Chimney Conversion Kit from Natural Gas to Propane LOG SET Installation Aeration AdjustmentGAS Connection High ElevationA02-65 Valve Description GAS Pipe Pressure TestingFinal Check Optional RemoteControl Wiring Diagram Operating Instructions Copy of the Lighting Plate Instructions Temperatures keep children, clothingClean. See installation Maintenance Glass Replacement Latch AdjustmentInstalling Glass Never operate your unit with bro- ken glassRemoving Valve FAN MaintenanceBefore removing the valve To remove fanMaintenance U37 Main Assembly Parts ListU37 Burner & LOG Assembly U37 Door Assemblies Conditions WarrantyInstaller Please complete the following information