INSTALLATION
TABLE 1
MINIMUM RECOMMENDED FLUE HEIGHTS IN FEET
(Measured from the top of the unit)
|
| # OF ELBOWS |
|
|
|
| |
ELEVATION (FT) |
|
|
|
|
|
|
|
ABOVE SEA LEVEL | 0 | 2 x 15o | 4 x 15o | 2 x 30o | 4 x 30o | 2 x 45o | 4 x 45o |
12.0 | 13.0 | 14.0 | 15.0 | 18.0 | 16.0 | 20.0 | |
12.5 | 13.5 | 14.5 | 15.5 | 19.0 | 16.5 | 21.0 | |
13.0 | 14.0 | 15.0 | 16.0 | 19.5 | 17.0 | 21.5 | |
13.5 | 14.5 | 15.5 | 17.0 | 20.0 | 18.0 | 22.5 | |
14.0 | 15.0 | 16.0 | 17.5 | 21.0 | 18.5 | 23.0 | |
14.5 | 15.5 | 17.0 | 18.0 | 21.5 | 19.0 | 24.0 | |
15.0 | 16.0 | 17.5 | 18.5 | 22.5 | 20.0 | 25.0 | |
15.5 | 16.5 | 18.0 | 19.0 | 23.0 | 20.5 | 25.5 | |
16.0 | 17.0 | 18.5 | 20.0 | 24.0 | 21.0 | 26.5 | |
16.5 | 17.5 | 19.0 | 20.5 | 24.5 | 22.0 | 27.0 |
NOTE: No more than two offsets (four elbows) allowed. Two 45o elbows equal one 90o elbow.
RECOMMENDED
HEIGHTS FOR
WOODSTOVE FLUE
Simple rules on draft. See Table 1.
1)At sea level minimum height is 12' straight.
2)Add the following vertical height to compensate for:
45 deg. elbow | = 1 ft. |
90 deg. elbow | = 2 ft. |
"T" | = 3 ft. |
Each foot of horizontal run = 2 ft.
3)Add 4% overall for each 1000' above sea level.
Example: a) |
|
|
= 3 ft. | ||
one "T" |
| = 3 ft. |
Total Addition (at sea level) | = 6 ft. | |
Example: b) |
|
|
One 90 deg. elbow | = 2 ft. | |
2 ft. of horizontal run | = 4 ft. | |
one "T" |
| = 3 ft. |
Total Addition (at sea level) | = 9 ft. | |
Recommended Flue Height | ||
Elevation | Example a) | Example b) |
0' | 18' | 21' |
1000' | 18.72' | 21.84' |
2000' | 19.44' | 22.68' |
5000' | 21.60' | 25.20' |
8000' | 23.76' | 27.72' |
12