Regency CS1200 installation manual Recommended Heights for Woodstove Flue, # of Elbows

Page 12

INSTALLATION

TABLE 1

MINIMUM RECOMMENDED FLUE HEIGHTS IN FEET

(Measured from the top of the unit)

 

 

# OF ELBOWS

 

 

 

 

ELEVATION (FT)

 

 

 

 

 

 

 

ABOVE SEA LEVEL

0

2 x 15o

4 x 15o

2 x 30o

4 x 30o

2 x 45o

4 x 45o

0-1000

12.0

13.0

14.0

15.0

18.0

16.0

20.0

1000-2000

12.5

13.5

14.5

15.5

19.0

16.5

21.0

2000-3000

13.0

14.0

15.0

16.0

19.5

17.0

21.5

3000-4000

13.5

14.5

15.5

17.0

20.0

18.0

22.5

4000-5000

14.0

15.0

16.0

17.5

21.0

18.5

23.0

5000-6000

14.5

15.5

17.0

18.0

21.5

19.0

24.0

6000-7000

15.0

16.0

17.5

18.5

22.5

20.0

25.0

7000-8000

15.5

16.5

18.0

19.0

23.0

20.5

25.5

8000-9000

16.0

17.0

18.5

20.0

24.0

21.0

26.5

9000-10000

16.5

17.5

19.0

20.5

24.5

22.0

27.0

NOTE: No more than two offsets (four elbows) allowed. Two 45o elbows equal one 90o elbow.

RECOMMENDED

HEIGHTS FOR

WOODSTOVE FLUE

Simple rules on draft. See Table 1.

1)At sea level minimum height is 12' straight.

2)Add the following vertical height to compensate for:

45 deg. elbow

= 1 ft.

90 deg. elbow

= 2 ft.

"T"

= 3 ft.

Each foot of horizontal run = 2 ft.

3)Add 4% overall for each 1000' above sea level.

Example: a)

 

 

1-1/2 ft. of horizontal run

= 3 ft.

one "T"

 

= 3 ft.

Total Addition (at sea level)

= 6 ft.

Example: b)

 

 

One 90 deg. elbow

= 2 ft.

2 ft. of horizontal run

= 4 ft.

one "T"

 

= 3 ft.

Total Addition (at sea level)

= 9 ft.

Recommended Flue Height

Elevation

Example a)

Example b)

0'

18'

21'

1000'

18.72'

21.84'

2000'

19.44'

22.68'

5000'

21.60'

25.20'

8000'

23.76'

27.72'

12

Regency CS1200 Freestanding Wood Stove

Image 12
Contents CS1200 Alterra Freestanding Wood Stove Regency Fireplace Product Safety Label Table of Contents Dimensions Unit DimensionsResidential Installation Modular Installation OptionsRoom AIR Minimum Clearance to Combustible Materials Minimum Alcove Clearance to Combustible Materials Minimum Alcove Clearance to Combustible MaterialsStep by Step Chimney Connector Installation Masonry Chimney Masonry FireplaceFactory Built Chimney Combustible Wall Chimney Connector PASS-THROUGHS Recommended Heights for Woodstove Flue # of ElbowsMobile Home Installation Listed Components for Mobile Home Installation InstallationBaffle and Tube Installation Brick Installation Door HandleSide Panel Installation Stainless Steel PanelsASH Drawer Option Ash drawer LidLower Surround Door Reversal Left to Right Side OpeningCast Door Reversal Left to Right Side Opening Optional Ashlip Installation Wood StorageBLOWER/FAN Installation FAN WiringFAN Operation Operating Instructions Draft ControlFirst Fire Safety Precautions ASH DisposalSafety Guidelines FAN MaintenanceMaintenance Door Catch AdjustmentGlass Replacement CreosoteParts List Main AssemblyFAN Assembly Fire BrickRegency CS1200 Freestanding Wood Stove Regency CS1200 Freestanding Wood Stove Regency CS1200 Freestanding Wood Stove Warranty Installer Please complete the following information