Regency CS1200 installation manual Baffle and Tube Installation Brick Installation, Door Handle

Page 15

 

 

INSTALLATION

 

 

BAFFLE AND TUBE INSTALLATION

BRICK INSTALLATION

1)If the two air tubes are installed continue on to Step 2), if not, follow the instructions below. Install the air tube into the holes in the side channels. The notch goes on the right hand side with the air holes facing toward the door. Slide the tube into the left hand side, as far as possible and then bring it back into the hole on the right hand side until it locks into position. If the tube will not slide in easily simply use a pair of vise grips or pliers and tap it into place with a hammer. A tighter fit will ensure the tube will not move when the unit is burning. Refer to the Mobile Home Installation section, though there are only two air tubes in the small units.

2)Slide the left baffle brick over the front air tube and then slide it back over the rear air tube.

Firebrick is included to extend the life of your stove and radiate heat more evenly. Check to see that all firebricks are in their correct positions and have not become misaligned during shipping.

The "AD" brick in the drawings above is the brick covering the Ash Dump hole that is used when the Ash Drawer Kit is installed.

Side View

AD Brick

DOOR HANDLE

The door handle can be removed and stored on a hanger located on the inside left in the wood storage area.

Front View

3)Tilt the left baffle brick up on top of the side channel and it will leave enough room to position the right baffle brick in the same manner as Step 1 above. Then reposition the left baffle brick flat on the air tube.

Front View

4)Important: push both baffle bricks so they are tight against the side walls.

Note: When getting the chimney cleaned, remove the baffle bricks for access to the flue, then replace them when cleaning is completed.

Regency CS1200 Freestanding Wood Stove

Handle stored on hangar

in wood storage area.

15

Image 15
Contents CS1200 Alterra Freestanding Wood Stove Regency Fireplace Product Safety Label Table of Contents Unit Dimensions DimensionsResidential Installation Modular Installation OptionsRoom AIR Minimum Clearance to Combustible Materials Minimum Alcove Clearance to Combustible Materials Minimum Alcove Clearance to Combustible MaterialsStep by Step Chimney Connector Installation Masonry Chimney Masonry FireplaceFactory Built Chimney Combustible Wall Chimney Connector PASS-THROUGHS # of Elbows Recommended Heights for Woodstove FlueMobile Home Installation Installation Listed Components for Mobile Home InstallationDoor Handle Baffle and Tube Installation Brick InstallationStainless Steel Panels Side Panel InstallationAsh drawer Lid ASH Drawer OptionLeft to Right Side Opening Lower Surround Door ReversalCast Door Reversal Left to Right Side Opening Wood Storage Optional Ashlip InstallationBLOWER/FAN Installation FAN WiringFAN Operation Operating Instructions Draft ControlFirst Fire ASH Disposal Safety PrecautionsFAN Maintenance Safety GuidelinesCreosote MaintenanceDoor Catch Adjustment Glass ReplacementMain Assembly Parts ListFire Brick FAN AssemblyRegency CS1200 Freestanding Wood Stove Regency CS1200 Freestanding Wood Stove Regency CS1200 Freestanding Wood Stove Warranty Installer Please complete the following information