INSTALLATION
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS
MEASUREMENTS "FROM UNIT" ARE FROM THE SIDE SHIELDS OF THE STOVE TO A SIDE WALL OR TO A CORNER, AND
FROM THE REAR HEAT SHIELD TO A BACK WALL
B | E |
A |
|
F
D
C
F
C
NOTE: Be aware that local Codes and Regulations may override some clearances listed in this manual.
Check with your local inspector.
Residential Installation “C” Vent (Single Wall)
Unit |
| From Unit |
| From Corner | From Flue | |||
|
|
|
|
|
|
|
|
|
CS1200 | A |
| B | C |
| D | E | F |
|
|
|
|
|
|
|
| |
13" |
| 11" | 8" |
| ||||
|
|
| ||||||
|
|
|
|
|
|
|
|
|
Residential Close Clearance (To be installed with required pipe components)
When the stove is installed as a close clearance residential unit, a listed double wall connector is required from the stove collar to the ceiling level.
|
| From Unit |
| From Corner | From Flue | |||
|
|
|
|
|
|
|
|
|
| A |
| B | C |
| D | E | F |
CS1200 |
|
|
|
|
|
|
|
|
11" |
| 7" | 7" |
| 14.5" | |||
|
|
| ||||||
|
|
|
|
|
|
|
|
|
Mobile Home Close Clearance (To be installed with required pipe components)
"C" Vent single wall pipe is not approved for Mobile Home installations. (Refer to Mobile Home Instructions.)
|
| From Unit |
| From Corner | From Flue | |||
|
|
|
|
|
|
|
|
|
| A |
| B | C |
| D | E | F |
CS1200 |
|
|
|
|
|
|
|
|
11" |
| 7" | 7" |
| 14.5" | |||
|
|
| ||||||
|
|
|
|
|
|
|
|
|
Regency CS1200 Freestanding Wood Stove
7