Regency P48-LP, P48-NG installation manual Table of Contents

Page 3

TABLE OF CONTENTS

 

Page

Safety Label

 

Safety Label

4

Installation

 

Important Message

5

Before You Start

5

General Safety Information

5

Installation Checklist

5

Manufactured Mobile Home

 

Additional Requirements

6

Unit Specifications

6

Locating Your Stove

6

Optional Duct System Kit

6

Optional Heat Release Kit

6

Hearth

6

Clearances

7

Mantels

8

Mantel Leg Clearances

8

Framing and Finishing

9

Top Assembly & Nailing Strips

10

Venting Introduction

10

Exterior Vent Termination Locations

11

Venting Arrangements

 

Horizontal Terminations

12

Simpson Dura-Vent Components List

13

Horizontal Terminations

14

Horizontal Venting

15

Vertical Venting

16

Vertical Terminations

18

Venting - Dura-Vent Horizontal Installations

20

Venting - Dura-Vent Vertical Termination

21

Direct Vent System (Flex)

22

System Data

23

High Elevation

23

Gas Line Installation

23

Pilot Adjustment

23

Gas Pipe Pressure Test

23

SIT Valve Description

23

Brick Panel Installation

24

Log Set Installation

25

Standard Flush Door

28

Flush Louvers

28

 

Page

Flush Trim

28

Bay Door

29

Bay Trim

29

Bay Louvers

29

Finishing Trim

30

Double Screen Door

30

Remote Control (optional)

31

Remote Wall Switch (optional)

31

Wall Thermostat (optional)

31

Wiring Diagram

32

Optional Fan

33

Conversion to Propane

34

Operating Instructions

 

Operating Instructions

35

Lighting Procedure

35

Shutdown Procedure

35

First Fire

35

Aeration Adjustment

35

Normal Operating Sounds of

 

Gas Appliances

36

Lighting Plate Instructions

36

Maintenance

 

Maintenance Instructions

37

General Vent Maintenance

37

Log Replacement

37

Thermopile/Thermocouple

37

Glass Gasket

37

Gold-Plated Louvers

37

Door Glass

38

Bay Glass Replacement

38

Installing Valve

38

RemovingValve

39

Parts List

 

Replacement/Spare Parts List

40

Warranty

 

Warranty

47

Regency P48 Zero Clearance Direct Vent Gas Fireplace

3

Image 3
Contents P48 Gas Fireplace Regency P48 Zero Clearance Direct Vent Gas Fireplace To the New OwnerTable of Contents Tiquetteé Pasne Cetteenlever Thisremove /LABEL Safety LabelSave These Instructions InstallationGeneral Safety Information Installation ChecklistOptional Heat Release Unit Specifications Locating Your GAS StoveManufactured Mobile Home Additional Requirements Optional Duct SystemMax. Depth 36 914mm ClearancesMantel CeilingMantel LEG Clearances MantelsFraming & Finishing Top Facing Support Side Nailing Strips Unit Assembly Prior to InstallationTop Standoff Assembly Venting IntroductionAir supply outlet VentRegency Direct Vent System Flex Horizontal Terminations Only VentingParts not supplied by Dura-Vent Simpson DURA-VENT VentingSimpson DURA-VENT Venting Components List DescriptionRegency Direct Vent System Flex Venting Arrangements Horizontal TerminationsHorizontal Venting with Three 3 90o Elbows Horizontal Venting with Two 2 90o ElbowsMin Max Min Max Min Max Vertical Venting with Two 2 90o ElbowsOption + H1 V + Vertical Venting with Three 3 90o ElbowsSimpson DURA-VENT Direct Vent GS System Venting Arrangements Vertical TerminationsInstallation Horizontal Installations Vertical Termination Offset ChartFor Regency Direct Vent System Flex Installation ProceduresHigh Elevation GAS Line InstallationPilot Adjustment GAS Pipe Pressure TestingBottom Clips Brick Panels Installation02-88 02-90 02-87 02-89 02-86 02-85 02-84 02-83 LOG SET Installation02-88 02-83 02-86 02-85 02-89 02-84 02-8902-90 02-8602-84 02-87 02-88 02-8502-83Standard Flush Door Flush LouversNot under the gas line Optional BAY Door BAY LouversOptional Bay Trim Double Screen Door Optional Finishing TrimThermostat Wire Table Option Remote ControlDo not cut the ground terminal off under any circumstances Wiring DiagramInstalling the Optional FAN Shut the power offTo Remove the Fan Conversion Kit Contains Operating Instructions Copy of the Lighting Plate Instructions Normal Operating Sounds GAS AppliancesMaintenance Installing Valve Bay Glass ReplacementDoor Glass Shut off the gas supply Removing ValveP48 Main Assembly Parts List102 100 P48 Burner & LOG Assembly P48 Flush Door & Louvers P48 BAY Front & Louvers Regency P48 Zero Clearance Direct Vent Gas Fireplace Regency P48 Zero Clearance Direct Vent Gas Fireplace Conditions WarrantyInstaller Please complete the following information

P48-NG, P48-LP specifications

The Regency P48-NG and P48-LP are notable entrants in the world of propane heating solutions, designed to meet the needs of both residential and commercial users. These high-efficiency models combine modern technology with user-friendly features, making them a popular choice for those looking to enhance their heating systems.

One of the standout features of the P48-NG and P48-LP is their powerful heating capacity. Both models are engineered to deliver consistent warmth, effectively heating spaces of various sizes. The P48-NG operates efficiently on natural gas, while the P48-LP is designed for use with liquid propane, providing versatility depending on available fuel sources. Suitable for a wide range of applications, these models can easily accommodate homes, workshops, and even larger commercial spaces.

In terms of technology, the Regency P48 series employs advanced burner systems to optimize combustion and maximize energy efficiency. This ensures that users experience lower energy bills while also reducing their carbon footprint. The units also feature a patented air mixing system that contributes to cleaner burning and improved airflow, resulting in a more comfortable and uniform heat distribution throughout the space.

Another significant characteristic of the P48-NG and P48-LP is their remarkable design. The models boast a sleek, contemporary appearance that fits seamlessly into a variety of decors, from rustic to modern. The large viewing area offers an impressive flame presentation, creating a mesmerizing ambiance that enhances the living space.

Additionally, safety features are paramount in the design of the Regency P48 series. Both models include advanced safety controls, such as an automatic shut-off system in the event of gas leaks or operational anomalies, ensuring peace of mind for users. The installation of these units is straightforward, and they comply with current safety standards, making them a reliable choice for any environment.

The P48-NG and P48-LP also incorporate user-friendly controls that allow for easy temperature adjustments. Remote control options are available, adding convenience for users who wish to manage their heating system from a distance. With all these features combined, the Regency P48-NG and P48-LP are innovative heating solutions that embody efficiency, safety, and style, catering to the modern heating needs of today’s users.