Regency P48-NG, P48-LP Installation Procedures, For Regency Direct Vent System Flex

Page 22

INSTALLATION

INSTALLATION

PROCEDURES

for Regency Direct Vent

System (Flex)

1)Locate the unit in the framing, rough in the gas (preferably on the right side of the unit) and the electrical (Junction block is on the left side) on the left. Locate the centerline of the termination and mark wall according- ly. Cut a 11"(279mm) hole in the wall (inside dimension).

Note: A top clearance of 2-1/2"(64mm) and side & bottom clearance of

1-1/2"(38mm) must be maintained except that only a 1" (25mm) clear- ance is needed at the termination end. We recommend framing a 11"(279mm) x 11"(279mm) (inside dimensions) hole to give struc- tural rigidity for mounting the ter- mination.

Note: To make the installation more aesthetically pleas- ing, we recom- mend framing out a square to mount the terminal to.

Note: If installing termination on a siding covered wall, furring strips must be used to ensure that the termi- nation is not recessed into the siding.

2)Level the fireplace and fasten it to the framing using nails or screws through the nailing strips.

3)Assemble the vent assembly by applying Mill Pac to the 5"(127mm) inner collar of the termination and slipping the 5"(127mm) liner over it at least 1-3/8" (35mm). Fasten with the 3 screws (drilling pilot holes will make this easier). Apply Mill Pac or high temper- ature silicone to the 8"(203mm) flex pipe and slip it over the 8" outer collar of the vent terminal at least 1-3/8"(35mm) and fasten with the 3 screws.

NOTE: Horizontal sections must be sup- ported at intervals not exceeding 3 feet (0.9 meter). (Flame picture and performance will be affected by sags in the liner).

4)Separate the 2 halves of the wall thimble and securely fasten the one with the tabs to the outside wall making sure that the tabs are on top and bottom. Fasten the other thimble half to the inside wall. The thimble halves slip inside each other and can be adjusted for 2 x 4 or 2 x 6 walls. The liners must slip over the collars a minimum of 1-3/8".

5)Slip the assembled liner and termination assembly through the thimble making sure the termination cap faces up (there are markings on the cap that show which way is up). This will position the termination cap with proper down slope for draining water. Fasten the cap to the outer wall with the 4 supplied screws.

6)Pull the centre 5"(127mm) liner and outer 8"(203mm) liner out enough to slip over the flue collars of the fireplace. (You may wish to cut the liner shorter to make it more workable.) Do not bend liner more than 90o.

7)Apply Mill Pac over the fireplace inner collar and slip the 5"(127mm) liner down over it and attach with 3 supplied screws.

8)Do the same with the 8"(203mm) liner.

9)Apply a bead of silicone between the thim- ble and termination and around the outer edge of the terminal at the wall in order to keep the water out.

IMPORTANT: Do not locate termination hood where excessive snow or ice build- up may occur. Be sure to check vent termination area after snow falls, and clear to prevent accidental blockage of venting system. When using snow blowers, make sure snow is not directed towards vent termination area.

ASTROCAP XL

DIMENSIONS

22

Regency P48 Zero Clearance Direct Vent Gas Fireplace

Image 22
Contents P48 Gas Fireplace To the New Owner Regency P48 Zero Clearance Direct Vent Gas FireplaceTable of Contents Safety Label Tiquetteé Pasne Cetteenlever Thisremove /LABELInstallation Checklist InstallationGeneral Safety Information Save These InstructionsOptional Duct System Unit Specifications Locating Your GAS StoveManufactured Mobile Home Additional Requirements Optional Heat ReleaseCeiling ClearancesMantel Max. Depth 36 914mmMantels Mantel LEG ClearancesFraming & Finishing Venting Introduction Unit Assembly Prior to InstallationTop Standoff Assembly Top Facing Support Side Nailing StripsVent Air supply outletVenting Regency Direct Vent System Flex Horizontal Terminations OnlyDescription Simpson DURA-VENT VentingSimpson DURA-VENT Venting Components List Parts not supplied by Dura-VentVenting Arrangements Horizontal Terminations Regency Direct Vent System FlexHorizontal Venting with Two 2 90o Elbows Horizontal Venting with Three 3 90o ElbowsVertical Venting with Two 2 90o Elbows Min Max Min Max Min MaxVertical Venting with Three 3 90o Elbows Option + H1 V +Venting Arrangements Vertical Terminations Simpson DURA-VENT Direct Vent GS SystemInstallation Horizontal Installations Offset Chart Vertical TerminationInstallation Procedures For Regency Direct Vent System FlexGAS Pipe Pressure Testing GAS Line InstallationPilot Adjustment High ElevationBrick Panels Installation Bottom ClipsLOG SET Installation 02-88 02-90 02-87 02-89 02-86 02-85 02-84 02-8302-88 02-83 02-86 02-85 02-89 02-84 02-87 02-88 02-8502-83 02-8902-90 02-8602-84Flush Louvers Standard Flush DoorNot under the gas line BAY Louvers Optional BAY DoorOptional Bay Trim Optional Finishing Trim Double Screen DoorOption Remote Control Thermostat Wire TableWiring Diagram Do not cut the ground terminal off under any circumstancesShut the power off Installing the Optional FANTo Remove the Fan Conversion Kit Contains Operating Instructions Normal Operating Sounds GAS Appliances Copy of the Lighting Plate InstructionsMaintenance Bay Glass Replacement Installing ValveDoor Glass Removing Valve Shut off the gas supplyParts List P48 Main Assembly102 100 P48 Burner & LOG Assembly P48 Flush Door & Louvers P48 BAY Front & Louvers Regency P48 Zero Clearance Direct Vent Gas Fireplace Regency P48 Zero Clearance Direct Vent Gas Fireplace Warranty ConditionsInstaller Please complete the following information

P48-NG, P48-LP specifications

The Regency P48-NG and P48-LP are notable entrants in the world of propane heating solutions, designed to meet the needs of both residential and commercial users. These high-efficiency models combine modern technology with user-friendly features, making them a popular choice for those looking to enhance their heating systems.

One of the standout features of the P48-NG and P48-LP is their powerful heating capacity. Both models are engineered to deliver consistent warmth, effectively heating spaces of various sizes. The P48-NG operates efficiently on natural gas, while the P48-LP is designed for use with liquid propane, providing versatility depending on available fuel sources. Suitable for a wide range of applications, these models can easily accommodate homes, workshops, and even larger commercial spaces.

In terms of technology, the Regency P48 series employs advanced burner systems to optimize combustion and maximize energy efficiency. This ensures that users experience lower energy bills while also reducing their carbon footprint. The units also feature a patented air mixing system that contributes to cleaner burning and improved airflow, resulting in a more comfortable and uniform heat distribution throughout the space.

Another significant characteristic of the P48-NG and P48-LP is their remarkable design. The models boast a sleek, contemporary appearance that fits seamlessly into a variety of decors, from rustic to modern. The large viewing area offers an impressive flame presentation, creating a mesmerizing ambiance that enhances the living space.

Additionally, safety features are paramount in the design of the Regency P48 series. Both models include advanced safety controls, such as an automatic shut-off system in the event of gas leaks or operational anomalies, ensuring peace of mind for users. The installation of these units is straightforward, and they comply with current safety standards, making them a reliable choice for any environment.

The P48-NG and P48-LP also incorporate user-friendly controls that allow for easy temperature adjustments. Remote control options are available, adding convenience for users who wish to manage their heating system from a distance. With all these features combined, the Regency P48-NG and P48-LP are innovative heating solutions that embody efficiency, safety, and style, catering to the modern heating needs of today’s users.