Regency P48-NG, P48-LP installation manual Door Glass, Installing Valve, Bay Glass Replacement

Page 38

MAINTENANCE

DOOR GLASS

Bay Glass Replacement

INSTALLING VALVE

Your Regency fireplace is supplied with high temperature 5mm-Ceramic glass. If your glass requires cleaning, we recommend using an approved glass cleaner available at all author- ized dealers. Do not use abrasive materials.

CAUTION&WARNINGS:

*Do not clean when the glass is hot.

*The use of substitute glass will void all product warranties.

*Care must be taken to avoid breakage of the glass.

*Do not strike or abuse the glass.

*Do not operate this fireplace without the glass front or with a cracked or broken glass front.

*Wear gloves when removing damaged or broken glass.

*Replacement of the glass panel(s) should be done by a licensed or qualified service per son.

1)Remove the door from the unit and place on a soft surface to prevent scratching.

2)Remove the nuts holding the glass clips in place and remove.

3)Replace the glass. The glass must have gasketing around it.

1)

Attach the valve to the valve bracket with

 

the 4 (m5x8 metric) screws provided.

2)

Reconnect the "gas out" flare fitting with an

 

11/16" wrench.

3)

Reconnect the "gas out" flare nut with a 13/

 

16" wrench.

4)

Install piezo ignitor push button assembly

 

and reconnect wire.

5)

Reconnect the quick drop out thermocouple

 

nut with a 9mm wrench.

6)

Reconnect the pilot tube nut with a 7/16"

 

wrench.

7)

Scrape off the old gasket from the floor of

 

the firebox and from the valve tray assem-

 

bly.

8)

Install a new gasket and reinstall the valve

GLASSREPLACEMENT

In the event that you break your glass by impact, purchase your replacement from an authorized Regency dealer only.

Replacement glass is shipped already installed into the door frame. Reinstall as per Glass Door Installation on page 28.

CAUTION: Wear gloves when re- moving damaged or broken glass.

WARNING: Do not operate the appliance with the glass panels removed, cracked or broken. Re- placement of the glass panels should be done by a licensed or qualified service person.

4)Reverse the previous steps, replace the glass clips and fasten with the nuts but do not over tighten, as this can break the glass.

5)Replace door on the stove and check the seal.

tray assembly.

Note: Failure to install a new gasket may severely affect the appliance performance.

9)Reinstall the 10 hold down screws.

10)Hook up the 2 TP and 2 TH wires to the appropriate connections on the valve.

11)Reinstall the two bottom deflectors and brick panels.

12)Install burner and grate assembly.

13)Hook up the gas line and check for gas leaks with a soap and water solution or a gas leak detector. (Do not use open flame for leak testing.)

14)Fire up the unit temporarily.

15)Check the manifold pressure.

16)Reinstall the logs and brick panels as need- ed.

17)Close the door and replace the louvers.

18)Fire up the unit again and check for proper flame appearance and glow on logs.

38

Regency P48 Zero Clearance Direct Vent Gas Fireplace

Image 38
Contents P48 Gas Fireplace To the New Owner Regency P48 Zero Clearance Direct Vent Gas FireplaceTable of Contents Safety Label Tiquetteé Pasne Cetteenlever Thisremove /LABELInstallation Checklist InstallationGeneral Safety Information Save These InstructionsOptional Duct System Unit Specifications Locating Your GAS StoveManufactured Mobile Home Additional Requirements Optional Heat ReleaseCeiling ClearancesMantel Max. Depth 36 914mmMantels Mantel LEG ClearancesFraming & Finishing Venting Introduction Unit Assembly Prior to InstallationTop Standoff Assembly Top Facing Support Side Nailing StripsVent Air supply outletVenting Regency Direct Vent System Flex Horizontal Terminations OnlyDescription Simpson DURA-VENT VentingSimpson DURA-VENT Venting Components List Parts not supplied by Dura-VentVenting Arrangements Horizontal Terminations Regency Direct Vent System FlexHorizontal Venting with Two 2 90o Elbows Horizontal Venting with Three 3 90o ElbowsVertical Venting with Two 2 90o Elbows Min Max Min Max Min MaxVertical Venting with Three 3 90o Elbows Option + H1 V +Venting Arrangements Vertical Terminations Simpson DURA-VENT Direct Vent GS SystemInstallation Horizontal Installations Offset Chart Vertical TerminationInstallation Procedures For Regency Direct Vent System FlexGAS Pipe Pressure Testing GAS Line InstallationPilot Adjustment High ElevationBrick Panels Installation Bottom ClipsLOG SET Installation 02-88 02-90 02-87 02-89 02-86 02-85 02-84 02-8302-88 02-83 02-86 02-85 02-89 02-84 02-87 02-88 02-8502-83 02-8902-90 02-8602-84Not under the gas line Standard Flush DoorFlush Louvers Optional Bay Trim Optional BAY DoorBAY Louvers Optional Finishing Trim Double Screen DoorOption Remote Control Thermostat Wire TableWiring Diagram Do not cut the ground terminal off under any circumstancesTo Remove the Fan Installing the Optional FANShut the power off Conversion Kit Contains Operating Instructions Normal Operating Sounds GAS Appliances Copy of the Lighting Plate InstructionsMaintenance Door Glass Installing ValveBay Glass Replacement Removing Valve Shut off the gas supplyParts List P48 Main Assembly102 100 P48 Burner & LOG Assembly P48 Flush Door & Louvers P48 BAY Front & Louvers Regency P48 Zero Clearance Direct Vent Gas Fireplace Regency P48 Zero Clearance Direct Vent Gas Fireplace Warranty ConditionsInstaller Please complete the following information