Regency P48-NG Unit Assembly Prior to Installation, Venting Introduction, Top Standoff Assembly

Page 10

INSTALLATION

UNIT ASSEMBLY

PRIOR TO

INSTALLATION

The Top Facing Support, the Side Nailing Strips and the 2 Top Standoffs must be correctly positioned and attached to the top before unit is slipped into position.

Top Standoff Assembly

The top standoffs are shipped in a flat position and must be folded into shape and attached.

1)Remove the standoffs from the fireplace top.

2)Take each standoff and bend into the cor- rect shape. Bend up at the bend lines until the screw holes in the standoff and the pre- punched screw holes on the fireplace top line up.

3)Attach the standoff securely to the top with 2 screws per standoff (on opposite cor- ners).

Top Facing Support and

Side Nailing Strips

Determine the total thickness of facing material (e.g. drywall plus ceramic tiles) to allow the finished surface to be flush with the front of the unit. Total facing thickness can vary from 1/2" (13mm) to 1-1/4" (32mm) thick.

The Top Facing Support & Side Nailing Strips can be mounted in 3 different positions depend- ing on the thickness of the facing material.

Screw

Facing Material

Position

Depth

 

 

 

A

1/2" / 13mm

B

7/8" / 22mm

C*

1-1/4" / 32mm

 

 

 

*For "C" screw position the top facing support is reversed.

1)Mount Top Facing Support using the 3 supplied screws into the three pre-punched screw holes on the top front of the unit. Use hole positions A, B, or C depending on your facing depth.

"C" Screw Position:

For a facing material depth of 1-1/4" (32mm), the top facing support must be reversed.

2)Use the same screw hole position for the Side Nailing Strips as was used for the Top Facing Support. Attach each side nailing strip using 3 screws.

VENTING

INTRODUCTION

The P48 uses the "balanced flue" technology Co Axial system. The inner liner vents products of combustion to the outside while the outer liner draws outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney.

Note: These flue pipes must not be con- nected to any other appliance.

The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or gas burning appliance. Each direct vent gas appliance must use it's own separate vent system. Common vent systems are prohibited.

10

Regency P48 Zero Clearance Direct Vent Gas Fireplace

Image 10
Contents P48 Gas Fireplace To the New Owner Regency P48 Zero Clearance Direct Vent Gas FireplaceTable of Contents Safety Label Tiquetteé Pasne Cetteenlever Thisremove /LABELInstallation Checklist InstallationGeneral Safety Information Save These InstructionsOptional Duct System Unit Specifications Locating Your GAS StoveManufactured Mobile Home Additional Requirements Optional Heat Release Ceiling Clearances Mantel Max. Depth 36 914mmMantels Mantel LEG ClearancesFraming & Finishing Venting Introduction Unit Assembly Prior to InstallationTop Standoff Assembly Top Facing Support Side Nailing StripsVent Air supply outletVenting Regency Direct Vent System Flex Horizontal Terminations OnlyDescription Simpson DURA-VENT VentingSimpson DURA-VENT Venting Components List Parts not supplied by Dura-VentVenting Arrangements Horizontal Terminations Regency Direct Vent System FlexHorizontal Venting with Two 2 90o Elbows Horizontal Venting with Three 3 90o ElbowsVertical Venting with Two 2 90o Elbows Min Max Min Max Min MaxVertical Venting with Three 3 90o Elbows Option + H1 V +Venting Arrangements Vertical Terminations Simpson DURA-VENT Direct Vent GS SystemInstallation Horizontal Installations Offset Chart Vertical TerminationInstallation Procedures For Regency Direct Vent System FlexGAS Pipe Pressure Testing GAS Line InstallationPilot Adjustment High ElevationBrick Panels Installation Bottom ClipsLOG SET Installation 02-88 02-90 02-87 02-89 02-86 02-85 02-84 02-8302-88 02-83 02-86 02-85 02-89 02-84 02-87 02-88 02-8502-83 02-8902-90 02-8602-84Flush Louvers Standard Flush DoorNot under the gas line BAY Louvers Optional BAY DoorOptional Bay Trim Optional Finishing Trim Double Screen DoorOption Remote Control Thermostat Wire TableWiring Diagram Do not cut the ground terminal off under any circumstancesShut the power off Installing the Optional FANTo Remove the Fan Conversion Kit Contains Operating Instructions Normal Operating Sounds GAS Appliances Copy of the Lighting Plate InstructionsMaintenance Bay Glass Replacement Installing ValveDoor Glass Removing Valve Shut off the gas supplyParts List P48 Main Assembly102 100 P48 Burner & LOG Assembly P48 Flush Door & Louvers P48 BAY Front & Louvers Regency P48 Zero Clearance Direct Vent Gas Fireplace Regency P48 Zero Clearance Direct Vent Gas Fireplace Warranty ConditionsInstaller Please complete the following information