Regency P48-NG, P48-LP installation manual Conversion Kit Contains

Page 34

INSTALLATION

CONVERSION KIT FROM NATURAL GAS TO PROPANE MODEL #370-969

FOR P48 USING SIT 820 NOVA GAS VALVE

THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER

IF IN DOUBT DO NOT DO THIS CONVERSION !!

Conversion Kit Contains:

Qty. Part #

Description

1

910-018

SIT Conversion Kit-50%

 

 

Turndown LP

1

910-037

LP Injector (Pilot Orifice)

1

904-434

Burner Orifice #47

1

908-255

Decal "Converted to Propane"

1908-529 5/32" Allen Key

1918-032 Instruction Sheet

1)Remove the louvers and trim kit. Remove the front door.

2)Remove the logs, embers.

3)Remove the grate by lifting straight up.

4)Remove the burner assembly by removing the 1 Phillips head screw and then slide the burner assembly away from the orifice and lift out.

5)Pull off the pilot cap to expose the pilot orifice.

6)Unscrew the pilot orifice with the allen key and replace with the LP pilot orifice in the kit and replace pilot cap.

7)Remove burner orifice with a 1/2" wrench and discard. Use another wrench to hold on to the elbow behind the orifice.

Diagram 1: Remove the left screw and then slide the burner assembly away from the orifice and lift out.

Burner Orifice

8)Reinstall new burner orifice LP stamped #47 and tighten.

9)Remove and discard the 3 pressure regu- lator mounting screws (A), pressure regu- lator tower (B) and diaphragm (C).

10)Insure that the rubber gasket (D) is properly positioned and install the new HI/LO pres- sure regulator assembly to the valve using the new screws (E) supplied with the kit. Tighten screws securely.

11)Reverse steps 4) to 1).

12)Attach clear label "This unit has been con- verted to Propane" near or on the serial # decal. Attach white label "This valve has been converted from NG to LPG using SIT conversion Kit Code 0.907.202" onto the valve.

13)Replace yellow "Natural Gas" label with red "Propane" label

14)Check for gas leaks.

15)Check inlet and outlet pressures.

16)Check operation of flame control.

17)Check for proper flame appearance and glow on logs.

34

Regency P48 Zero Clearance Direct Vent Gas Fireplace

Image 34
Contents P48 Gas Fireplace To the New Owner Regency P48 Zero Clearance Direct Vent Gas FireplaceTable of Contents Safety Label Tiquetteé Pasne Cetteenlever Thisremove /LABELInstallation Checklist InstallationGeneral Safety Information Save These InstructionsOptional Duct System Unit Specifications Locating Your GAS StoveManufactured Mobile Home Additional Requirements Optional Heat ReleaseCeiling ClearancesMantel Max. Depth 36 914mmMantels Mantel LEG ClearancesFraming & Finishing Venting Introduction Unit Assembly Prior to InstallationTop Standoff Assembly Top Facing Support Side Nailing StripsVent Air supply outletVenting Regency Direct Vent System Flex Horizontal Terminations OnlyDescription Simpson DURA-VENT VentingSimpson DURA-VENT Venting Components List Parts not supplied by Dura-VentVenting Arrangements Horizontal Terminations Regency Direct Vent System FlexHorizontal Venting with Two 2 90o Elbows Horizontal Venting with Three 3 90o ElbowsVertical Venting with Two 2 90o Elbows Min Max Min Max Min MaxVertical Venting with Three 3 90o Elbows Option + H1 V +Venting Arrangements Vertical Terminations Simpson DURA-VENT Direct Vent GS SystemInstallation Horizontal Installations Offset Chart Vertical TerminationInstallation Procedures For Regency Direct Vent System FlexGAS Pipe Pressure Testing GAS Line InstallationPilot Adjustment High ElevationBrick Panels Installation Bottom ClipsLOG SET Installation 02-88 02-90 02-87 02-89 02-86 02-85 02-84 02-8302-88 02-83 02-86 02-85 02-89 02-84 02-87 02-88 02-8502-83 02-8902-90 02-8602-84Flush Louvers Standard Flush DoorNot under the gas line BAY Louvers Optional BAY DoorOptional Bay Trim Optional Finishing Trim Double Screen DoorOption Remote Control Thermostat Wire TableWiring Diagram Do not cut the ground terminal off under any circumstancesShut the power off Installing the Optional FANTo Remove the Fan Conversion Kit Contains Operating Instructions Normal Operating Sounds GAS Appliances Copy of the Lighting Plate InstructionsMaintenance Bay Glass Replacement Installing ValveDoor Glass Removing Valve Shut off the gas supplyParts List P48 Main Assembly102 100 P48 Burner & LOG Assembly P48 Flush Door & Louvers P48 BAY Front & Louvers Regency P48 Zero Clearance Direct Vent Gas Fireplace Regency P48 Zero Clearance Direct Vent Gas Fireplace Warranty ConditionsInstaller Please complete the following information

P48-NG, P48-LP specifications

The Regency P48-NG and P48-LP are notable entrants in the world of propane heating solutions, designed to meet the needs of both residential and commercial users. These high-efficiency models combine modern technology with user-friendly features, making them a popular choice for those looking to enhance their heating systems.

One of the standout features of the P48-NG and P48-LP is their powerful heating capacity. Both models are engineered to deliver consistent warmth, effectively heating spaces of various sizes. The P48-NG operates efficiently on natural gas, while the P48-LP is designed for use with liquid propane, providing versatility depending on available fuel sources. Suitable for a wide range of applications, these models can easily accommodate homes, workshops, and even larger commercial spaces.

In terms of technology, the Regency P48 series employs advanced burner systems to optimize combustion and maximize energy efficiency. This ensures that users experience lower energy bills while also reducing their carbon footprint. The units also feature a patented air mixing system that contributes to cleaner burning and improved airflow, resulting in a more comfortable and uniform heat distribution throughout the space.

Another significant characteristic of the P48-NG and P48-LP is their remarkable design. The models boast a sleek, contemporary appearance that fits seamlessly into a variety of decors, from rustic to modern. The large viewing area offers an impressive flame presentation, creating a mesmerizing ambiance that enhances the living space.

Additionally, safety features are paramount in the design of the Regency P48 series. Both models include advanced safety controls, such as an automatic shut-off system in the event of gas leaks or operational anomalies, ensuring peace of mind for users. The installation of these units is straightforward, and they comply with current safety standards, making them a reliable choice for any environment.

The P48-NG and P48-LP also incorporate user-friendly controls that allow for easy temperature adjustments. Remote control options are available, adding convenience for users who wish to manage their heating system from a distance. With all these features combined, the Regency P48-NG and P48-LP are innovative heating solutions that embody efficiency, safety, and style, catering to the modern heating needs of today’s users.