Regency P48-LP, P48-NG installation manual Removing Valve, Shut off the gas supply

Page 39

MAINTENANCE

REMOVING VALVE

7)Remove the right and left side deflectors by removing the 2 screws on each deflector.

1)Shut off the gas supply.

2)Remove the louvers (and bay door if it has been installed).

3)Open the flush door and remove the door.

4)Remove the logs and side brick panels, if installed.

5)Remove the grate by lifting up and out.

Grate

6)Remove the burner by removing the screw on the left side and then slide the burner to the left and lift out.

Remove the screw on the left

side of the burner.

Right Side

Deflector

Left Side

Deflector

8)Remove the base brick panels.

9)Disconnect the inlet gas line.

10)Remove the 10 Phillips head screws secur- ing the valve tray assembly in place and then lift the entire assembly out.

Lift entire valve tray

assembly out.

11)Disconnect the 2 TP wires and the 2 TH wires from the valve.

12)Undo the pilot tube from the valve with a 7/ 16" wrench.

13)Undo the quick drop out thermocouple nut on the valve with a 9mm (metric) wrench.

14)Remove the Piezo igniter wire and push button assembly.

Thermopile

Thermocouple

Pilot Nut

Wire

Wire

 

15)Undo the "gas out" flare nut with a 13/16" wrench.

16)Undo the "gas out" flare fitting with an 11/ 16" wrench.

17)Remove the 4 Phillips head screws from the sides of the valve bracket and remove valve.

Slide the burner to the left and lift out.

Hint: If you are using black pipe, ensure that there is a union by the valve, otherwise removal will be almost impossible.

Valve Tray

Assembly

Regency P48 Zero Clearance Direct Vent Gas Fireplace

39

Image 39
Contents P48 Gas Fireplace Regency P48 Zero Clearance Direct Vent Gas Fireplace To the New OwnerTable of Contents Tiquetteé Pasne Cetteenlever Thisremove /LABEL Safety LabelSave These Instructions InstallationGeneral Safety Information Installation ChecklistOptional Heat Release Unit Specifications Locating Your GAS StoveManufactured Mobile Home Additional Requirements Optional Duct SystemMax. Depth 36 914mm ClearancesMantel CeilingMantel LEG Clearances MantelsFraming & Finishing Top Facing Support Side Nailing Strips Unit Assembly Prior to InstallationTop Standoff Assembly Venting IntroductionAir supply outlet VentRegency Direct Vent System Flex Horizontal Terminations Only VentingParts not supplied by Dura-Vent Simpson DURA-VENT VentingSimpson DURA-VENT Venting Components List DescriptionRegency Direct Vent System Flex Venting Arrangements Horizontal TerminationsHorizontal Venting with Three 3 90o Elbows Horizontal Venting with Two 2 90o ElbowsMin Max Min Max Min Max Vertical Venting with Two 2 90o ElbowsOption + H1 V + Vertical Venting with Three 3 90o ElbowsSimpson DURA-VENT Direct Vent GS System Venting Arrangements Vertical TerminationsInstallation Horizontal Installations Vertical Termination Offset ChartFor Regency Direct Vent System Flex Installation ProceduresHigh Elevation GAS Line InstallationPilot Adjustment GAS Pipe Pressure TestingBottom Clips Brick Panels Installation02-88 02-90 02-87 02-89 02-86 02-85 02-84 02-83 LOG SET Installation02-88 02-83 02-86 02-85 02-89 02-84 02-8902-90 02-8602-84 02-87 02-88 02-8502-83Standard Flush Door Flush LouversNot under the gas line Optional BAY Door BAY LouversOptional Bay Trim Double Screen Door Optional Finishing TrimThermostat Wire Table Option Remote ControlDo not cut the ground terminal off under any circumstances Wiring DiagramInstalling the Optional FAN Shut the power offTo Remove the Fan Conversion Kit Contains Operating Instructions Copy of the Lighting Plate Instructions Normal Operating Sounds GAS AppliancesMaintenance Installing Valve Bay Glass ReplacementDoor Glass Shut off the gas supply Removing ValveP48 Main Assembly Parts List102 100 P48 Burner & LOG Assembly P48 Flush Door & Louvers P48 BAY Front & Louvers Regency P48 Zero Clearance Direct Vent Gas Fireplace Regency P48 Zero Clearance Direct Vent Gas Fireplace Conditions WarrantyInstaller Please complete the following information

P48-NG, P48-LP specifications

The Regency P48-NG and P48-LP are notable entrants in the world of propane heating solutions, designed to meet the needs of both residential and commercial users. These high-efficiency models combine modern technology with user-friendly features, making them a popular choice for those looking to enhance their heating systems.

One of the standout features of the P48-NG and P48-LP is their powerful heating capacity. Both models are engineered to deliver consistent warmth, effectively heating spaces of various sizes. The P48-NG operates efficiently on natural gas, while the P48-LP is designed for use with liquid propane, providing versatility depending on available fuel sources. Suitable for a wide range of applications, these models can easily accommodate homes, workshops, and even larger commercial spaces.

In terms of technology, the Regency P48 series employs advanced burner systems to optimize combustion and maximize energy efficiency. This ensures that users experience lower energy bills while also reducing their carbon footprint. The units also feature a patented air mixing system that contributes to cleaner burning and improved airflow, resulting in a more comfortable and uniform heat distribution throughout the space.

Another significant characteristic of the P48-NG and P48-LP is their remarkable design. The models boast a sleek, contemporary appearance that fits seamlessly into a variety of decors, from rustic to modern. The large viewing area offers an impressive flame presentation, creating a mesmerizing ambiance that enhances the living space.

Additionally, safety features are paramount in the design of the Regency P48 series. Both models include advanced safety controls, such as an automatic shut-off system in the event of gas leaks or operational anomalies, ensuring peace of mind for users. The installation of these units is straightforward, and they comply with current safety standards, making them a reliable choice for any environment.

The P48-NG and P48-LP also incorporate user-friendly controls that allow for easy temperature adjustments. Remote control options are available, adding convenience for users who wish to manage their heating system from a distance. With all these features combined, the Regency P48-NG and P48-LP are innovative heating solutions that embody efficiency, safety, and style, catering to the modern heating needs of today’s users.