Regency Wraps Complete Guide to Operating Instructions for the Regency P36 Indoor Fireplace

Page 30

OPERATING INSTRUCTIONS

OPTIONAL

FAN

240 Volt AC power is needed for the fan switch and blower.The fan can be hard wired if desired. Aterminal block is provided on the left hand side of the unit. A three wire power cord can also be used and plugged into a suitable receptacle.

Unit must be grounded at all times. Do not cut the ground terminal off under any circumstances.

1)Shut the power off.

2)Open the bottom louvre door.

3)Remove the terminal block cover.

4)Slide the fan in towards the rear of the unit and slip it over the two mounting studs.

Ensure that the fan blades do not rub against the valve tubing.

Optional: If you require extra space to slide the fan to the back, the left spring can be unhooked from the bracket.

5)Wire the fan to the terminal block as shown in the wiring diagram below.

6)Connect white wire from fan to neutral of terminal block.

7)Slide the thermodisc into the bracket clip on the underside of the fi rebox.

8)Connect black wire from fan to the thermodisc.

9)Connect fan ground cable to ground lug. Refer to wiring diagram.

10)Attach the ground wire to the stove (ground lug provided).

11)Attachblackwirefromthermodisctoterminal block.

12)Hard wire into terminal block and to fan speed controller. Wires not supplied.

Note: A 240 Volt AC power cord can be installed at rough-in stage so that the power is available. A three wire power cord can be used.

13)Attach the terminal block cover. If the left spring was unhooked in step 4), hook it back into the bracket.

To Remove the Fan

1)Shut the power off.

2)Reverse the above instructions.

Note: The bearings are lubricated for life. Do not lubricate them. Make sure you vacuum the fan area on a regular basis.

IMPORTANT:

These fans collect a lot of dust from within your home. Ensure you maintain these fan motors on a regular basis by vacuuming out the fan blades and housing using a soft brush nozzle.

OPERATING

INSTRUCTIONS

1)Read and understand these instructions before operating this appliance.

2)Check to see that all wiring is correct and enclosed to prevent possible shock.

3)Check to ensure there are no gas leaks.

4)Make sure the glass in the door frame is properly positioned. Never operate the appliance with the glass removed.

5)Verify that the flueing and cap are unobstructed.

6)Ensure that the brick panels are installed.

7)Verify log placement. If the pilot cannot be seen when lighting the unit, the logs have been incorrectly positioned.

8)The unit should never be turned off, and on again without a minimum of a 60 second wait.

30

Regency® P36-4 Gas Log Fireplace

Image 30
Contents Manual Please Keep These Instructions For Future ReferenceTo the NEW Owner Table of Contents Data Badge Data Badge Note Regency units areInstallation Checklist InstallationGeneral Safety Information Important MessageLocating Your GAS Fireplace Manufactured Mobile Home Additional RequirementsClearances Diagram Combustible MantelsMantel LEG Clearances Standard Framing DimensionsFraming Dimensions with Premium Flush Front Option Framing FinishingPremium Flush Front Spacer Installation Unit Assembly Prior to InstallationTop Standoff Assembly Flueing IntroductionExterior Flue Termination Locations Clearance k in mmFlueing Regency Direct Vent System Flex Horizontal Terminations OnlySimpson DURA-VENT Flueing Simpson DURA-VENT Flueing Components ListFlueing Arrangements Horizontal Terminations Regency Direct Vent System FlexRegency CO Axial Flue System Flex Flueing Arrangements Vertical Terminations Simpson DURA-VENT CO Axial Flue GS System LPG & NG45o elbows allowed Horizontal Terminations Dura-VentOffset Chart This allows for small adjustmentsVertical Terminations Shut off the gas supply InstalledConversion Kit Contains Qty Remove the louvers and bay door if it isAeration Adjustment GAS Line InstallationPilot Adjustment GAS Pipe Pressure TestingLOG SET Installation Optional Brick PanelsVermiculite Bracket Bracket Notch Rear Bracket5th Grate Tab 2nd Grate TabPlace embers in these 3 locations On the burner tray Flush LouvresOptional Flush Trim EmbersPremium Flush Front Installation Louver TabThermodisc Plate Thermodisc Cover Grommet Wire Cover Wall Switch Remote ControlWall Thermostat Wiring Standard WiringWiring with Premium Flush Front Option Operating Instructions Operating InstructionsOptional FAN To Remove the FanLighting Procedure First FireNormal Operating Sounds of GAS Appliances Maintenance Instructions General Flue MaintenanceCopy of the Lighting Plate Instructions Maintenance Removing Valve Installing ValveDiagram 2 Rear Log Stand Valve Tray Assembly ScrewsParts List Main AssemblyBurner Assembly & LOG SET BAY Front Assembly Flush Front Accessories DescriptionPremium Flush Front Assembly Cast Faceplate Assembly Regency P36-4 Gas Log Fireplace Regency P36-4 Gas Log Fireplace Exclusions WarrantyConditions General

P36-NG4, P36-LPG4 specifications

Regency Wraps has made a significant mark in the world of grill accessories with its high-quality products, particularly the P36-LPG4 and P36-NG4 wraps. These wraps are designed specifically for grill enthusiasts who value durability, functionality, and aesthetic appeal in their cooking equipment.

The P36-LPG4 model is tailored for those who prefer liquid propane as their fuel source. It boasts a robust construction that ensures longevity and resilience against the elements. One of the key features of the P36-LPG4 is its heat-resistant fabric, which is crafted to withstand high temperatures without compromising the integrity of the wrap. This makes it an ideal choice for situations where intense heat is a norm, providing both safety and performance.

On the other hand, the P36-NG4 model caters to natural gas users. Similar to its LPG counterpart, the P36-NG4 is engineered to handle the rigors of outdoor grilling while offering a stylish appearance. The wrap is designed to fit a range of traditional grills, ensuring a snug yet flexible fit that protects the grill from dust, debris, and harsh weather conditions.

Both models feature advanced technologies, including UV resistance, which helps in maintaining the vibrant colors and quality of the fabric over time. This is crucial for outdoor gear that often faces prolonged exposure to the sun, preserving the product's aesthetic charm as well as its functional attributes.

The characteristics of the P36-LPG4 and P36-NG4 wraps extend beyond mere protection. They are equipped with user-friendly features such as easy installation; most users can simply slip the wrap over their grill in seconds. The wraps are also lightweight, which enhances portability for grillers who like to take their equipment on the go.

Furthermore, both wraps are designed with ease of maintenance in mind. They can be cleaned effortlessly, ensuring that grill enthusiasts can maintain their equipment in pristine condition without excessive effort or time.

In summary, Regency Wraps offers the P36-LPG4 and P36-NG4 models as the ultimate solution for grill protection, combining style with superior functionality. With their durable construction, advanced technologies, and user-friendly design, these wraps are a worthy investment for any grilling aficionado looking to enhance their outdoor cooking experience.