Regency Wraps P36-LPG4, P36-NG4 manual Premium Flush Front Installation, Louver Tab

Page 24

INSTALLATION

PREMIUM FLUSH FRONT INSTALLATION

1)Unplug the power source.

2)Remove the top louver (if fi tted) by carefully pulling it out.

3)Install the premium fl ush front top louver in place by sliding the louver tabs into the louver brackets on the inside top of the fi rebox.

6)Remove the manual control switch bracket by undoing the 2 screws.

Louver Tab

7)Remove the burner ON/OFF switch from the bracket using a pair of pliers and remove the 2 screws that secure the 2 wires on the valve.

Burner ON/OFF

Switch

Premium Flush Front Top Louver in place.

4)Open the bottom louver.

5)Remove the bottom louver (if fi tted) by undoing the 2 screws which secure the louver to the hinges on the left and right side.

Valve

8)Install the new ON/OFF switch to the manual control switch bracket.

24

Regency® P36-4 Gas Log Fireplace

Image 24
Contents Manual Please Keep These Instructions For Future ReferenceTo the NEW Owner Table of Contents Data Badge Data Badge Note Regency units areInstallation General Safety InformationInstallation Checklist Important MessageLocating Your GAS Fireplace Manufactured Mobile Home Additional RequirementsClearances Diagram Combustible MantelsStandard Framing Dimensions Framing Dimensions with Premium Flush Front OptionMantel LEG Clearances Framing FinishingUnit Assembly Prior to Installation Top Standoff AssemblyPremium Flush Front Spacer Installation Flueing IntroductionExterior Flue Termination Locations Clearance k in mmFlueing Regency Direct Vent System Flex Horizontal Terminations OnlySimpson DURA-VENT Flueing Simpson DURA-VENT Flueing Components ListFlueing Arrangements Horizontal Terminations Regency Direct Vent System FlexRegency CO Axial Flue System Flex Flueing Arrangements Vertical Terminations Simpson DURA-VENT CO Axial Flue GS System LPG & NG45o elbows allowed Horizontal Terminations Dura-VentOffset Chart This allows for small adjustmentsVertical Terminations Installed Conversion Kit Contains QtyShut off the gas supply Remove the louvers and bay door if it isGAS Line Installation Pilot AdjustmentAeration Adjustment GAS Pipe Pressure TestingLOG SET Installation Optional Brick PanelsVermiculite Rear Bracket 5th Grate TabBracket Bracket Notch 2nd Grate TabFlush Louvres Optional Flush TrimPlace embers in these 3 locations On the burner tray EmbersPremium Flush Front Installation Louver TabThermodisc Plate Thermodisc Cover Grommet Wire Cover Wall Switch Remote ControlWall Thermostat Wiring Standard WiringWiring with Premium Flush Front Option Operating Instructions Optional FANOperating Instructions To Remove the FanLighting Procedure First FireNormal Operating Sounds of GAS Appliances Maintenance Instructions General Flue MaintenanceCopy of the Lighting Plate Instructions Maintenance Installing Valve Diagram 2 Rear Log Stand Valve Tray AssemblyRemoving Valve ScrewsParts List Main AssemblyBurner Assembly & LOG SET BAY Front Assembly Flush Front Accessories DescriptionPremium Flush Front Assembly Cast Faceplate Assembly Regency P36-4 Gas Log Fireplace Regency P36-4 Gas Log Fireplace Warranty ConditionsExclusions General

P36-NG4, P36-LPG4 specifications

Regency Wraps has made a significant mark in the world of grill accessories with its high-quality products, particularly the P36-LPG4 and P36-NG4 wraps. These wraps are designed specifically for grill enthusiasts who value durability, functionality, and aesthetic appeal in their cooking equipment.

The P36-LPG4 model is tailored for those who prefer liquid propane as their fuel source. It boasts a robust construction that ensures longevity and resilience against the elements. One of the key features of the P36-LPG4 is its heat-resistant fabric, which is crafted to withstand high temperatures without compromising the integrity of the wrap. This makes it an ideal choice for situations where intense heat is a norm, providing both safety and performance.

On the other hand, the P36-NG4 model caters to natural gas users. Similar to its LPG counterpart, the P36-NG4 is engineered to handle the rigors of outdoor grilling while offering a stylish appearance. The wrap is designed to fit a range of traditional grills, ensuring a snug yet flexible fit that protects the grill from dust, debris, and harsh weather conditions.

Both models feature advanced technologies, including UV resistance, which helps in maintaining the vibrant colors and quality of the fabric over time. This is crucial for outdoor gear that often faces prolonged exposure to the sun, preserving the product's aesthetic charm as well as its functional attributes.

The characteristics of the P36-LPG4 and P36-NG4 wraps extend beyond mere protection. They are equipped with user-friendly features such as easy installation; most users can simply slip the wrap over their grill in seconds. The wraps are also lightweight, which enhances portability for grillers who like to take their equipment on the go.

Furthermore, both wraps are designed with ease of maintenance in mind. They can be cleaned effortlessly, ensuring that grill enthusiasts can maintain their equipment in pristine condition without excessive effort or time.

In summary, Regency Wraps offers the P36-LPG4 and P36-NG4 models as the ultimate solution for grill protection, combining style with superior functionality. With their durable construction, advanced technologies, and user-friendly design, these wraps are a worthy investment for any grilling aficionado looking to enhance their outdoor cooking experience.