Regency Wraps P36-NG4 manual Flueing, Regency Direct Vent System Flex Horizontal Terminations Only

Page 11

INSTALLATION

FLUEING

Regency® Direct Vent System (Flex)

Horizontal Terminations Only

These fl ueing systems, in combination with the P36 Room Sealed Gas Fireplace, have been tested and listed as a Direct Vent type fl ue system by the Australian Gas Association. The location of the termination cap must conform to the requirements in the Flue Terminal Locations diagram in section "Exterior Flue Termination Locations."

Regency® Direct Vent (Flex) System Termination Kit (Part # 946-515) includes all the parts needed to install the P36 with a maximum run of 1200mm.

1)175mm dia. fl exible liner (1200mm length)

2)100mm dia. fl exible liner (1200mm length)

3)spring spacers (4)

4)thimble (2)

5)AstroCap termination cap (1)

6)screws (12)

7)tube of Mill Pac (1)

8)plated screws (8)

9)screws #8 x 1-1/2" Drill Point, Stainless Steel (4)

If longer runs are needed, the Regency® Direct Vent system (Flex) # 946-516 includes all the parts needed to install the P36 with a maximum 3.0m run.

1)175mm dia. fl exible liner (3.0m length)

2)100mm dia. fl exible liner (3.0m length)

3)spring spacers (7)

4)thimble (2)

5)AstroCap termination cap (1)

6)screws (12)

7)tube of Mill Pac (1)

8)plated screws (8)

9)screws #8 x 1-1/2" Drill Point, Stainless Steel (4)

 

Wall Thimble

 

AstroCap

4" (102mm)

Termination Cap

dia. flue pipe

(Part# 946-578/P)

6-7/8"

(patented)

spring spacer

(173mm)

 

dia. Flue pipe

 

Notes:

1)Liner sections should be continuous without any joints or seams.

2)Only Flex pipe purchased from Regency® may be used for Flex installations.

3)If you are installing the P36 into a Regency® Mantel Kit, use the minimum horizontal vent height (centre-line of 1029mm). Remember to include the mantel base in your calculations and to maintain the 32mm clearance (38mm with Flex) to the underside of the mantel top.

Regency® P36-4 Gas Log Fireplace

11

Image 11
Contents Please Keep These Instructions For Future Reference ManualTo the NEW Owner Table of Contents Data Badge Note Regency units are Data BadgeImportant Message InstallationGeneral Safety Information Installation ChecklistClearances Locating Your GAS FireplaceManufactured Mobile Home Additional Requirements Combustible Mantels DiagramFraming Finishing Standard Framing DimensionsFraming Dimensions with Premium Flush Front Option Mantel LEG ClearancesFlueing Introduction Unit Assembly Prior to InstallationTop Standoff Assembly Premium Flush Front Spacer InstallationClearance k in mm Exterior Flue Termination LocationsRegency Direct Vent System Flex Horizontal Terminations Only FlueingSimpson DURA-VENT Flueing Components List Simpson DURA-VENT FlueingRegency Direct Vent System Flex Flueing Arrangements Horizontal TerminationsRegency CO Axial Flue System Flex Simpson DURA-VENT CO Axial Flue GS System LPG & NG Flueing Arrangements Vertical Terminations45o elbows allowed Dura-Vent Horizontal TerminationsVertical Terminations Offset ChartThis allows for small adjustments Remove the louvers and bay door if it is InstalledConversion Kit Contains Qty Shut off the gas supplyGAS Pipe Pressure Testing GAS Line InstallationPilot Adjustment Aeration AdjustmentVermiculite LOG SET InstallationOptional Brick Panels 2nd Grate Tab Rear Bracket5th Grate Tab Bracket Bracket NotchEmbers Flush LouvresOptional Flush Trim Place embers in these 3 locations On the burner trayLouver Tab Premium Flush Front InstallationThermodisc Plate Thermodisc Cover Grommet Wire Cover Wall Thermostat Wall SwitchRemote Control Standard Wiring WiringWiring with Premium Flush Front Option To Remove the Fan Operating InstructionsOptional FAN Operating InstructionsNormal Operating Sounds of GAS Appliances Lighting ProcedureFirst Fire Copy of the Lighting Plate Instructions Maintenance InstructionsGeneral Flue Maintenance Maintenance Screws Installing ValveDiagram 2 Rear Log Stand Valve Tray Assembly Removing ValveMain Assembly Parts ListBurner Assembly & LOG SET BAY Front Assembly Description Flush Front AccessoriesPremium Flush Front Assembly Cast Faceplate Assembly Regency P36-4 Gas Log Fireplace Regency P36-4 Gas Log Fireplace General WarrantyConditions Exclusions

P36-NG4, P36-LPG4 specifications

Regency Wraps has made a significant mark in the world of grill accessories with its high-quality products, particularly the P36-LPG4 and P36-NG4 wraps. These wraps are designed specifically for grill enthusiasts who value durability, functionality, and aesthetic appeal in their cooking equipment.

The P36-LPG4 model is tailored for those who prefer liquid propane as their fuel source. It boasts a robust construction that ensures longevity and resilience against the elements. One of the key features of the P36-LPG4 is its heat-resistant fabric, which is crafted to withstand high temperatures without compromising the integrity of the wrap. This makes it an ideal choice for situations where intense heat is a norm, providing both safety and performance.

On the other hand, the P36-NG4 model caters to natural gas users. Similar to its LPG counterpart, the P36-NG4 is engineered to handle the rigors of outdoor grilling while offering a stylish appearance. The wrap is designed to fit a range of traditional grills, ensuring a snug yet flexible fit that protects the grill from dust, debris, and harsh weather conditions.

Both models feature advanced technologies, including UV resistance, which helps in maintaining the vibrant colors and quality of the fabric over time. This is crucial for outdoor gear that often faces prolonged exposure to the sun, preserving the product's aesthetic charm as well as its functional attributes.

The characteristics of the P36-LPG4 and P36-NG4 wraps extend beyond mere protection. They are equipped with user-friendly features such as easy installation; most users can simply slip the wrap over their grill in seconds. The wraps are also lightweight, which enhances portability for grillers who like to take their equipment on the go.

Furthermore, both wraps are designed with ease of maintenance in mind. They can be cleaned effortlessly, ensuring that grill enthusiasts can maintain their equipment in pristine condition without excessive effort or time.

In summary, Regency Wraps offers the P36-LPG4 and P36-NG4 models as the ultimate solution for grill protection, combining style with superior functionality. With their durable construction, advanced technologies, and user-friendly design, these wraps are a worthy investment for any grilling aficionado looking to enhance their outdoor cooking experience.