Regency P42-LP4, P42-NG4 installation manual Table of Contents

Page 3

TABLE OF CONTENTS

SAFETY LABEL

 

OPERATING INSTRUCTIONS

 

Copy of Safety Decal

4

Optional Remote Control

34

 

 

Optional Wall Switch

34

REQUIREMENTS

 

Optional Wall Thermostat

34

 

 

Operating Instructions

34

MA Code - CO Detector

5

Lighting Procedure

34

Copy Of The Lighting Plate Instructions

35

 

 

INSTALLATION

MAINTENANCE

 

Important Message

6

Before You Start

6

General Safety Information

6

Installation Checklist

6

Manufactured Mobile Home Additional Requirements ..

7

Locating Your Gas Fireplace

7

Unit Specifi cations

7

Heatwave Optional Duct System Kit#946-556

7

Optional Hearth

7

Clearances

8

Mantels

8

Mantel Leg Clearances

8

Framing And Finishing

9

Top Assembly & Nailing Strips

9

Venting Introduction

9

Vent Restrictor

9

Exterior Vent Termination Requirements

10

Venting

11

4” x 6-5/8” Rigid Pipe Cross Reference Chart

12

Rigid Pipe Venting

14

Horizontal Terminations

15

Vertical Terminations

17

Installation Procedures

23

High Elevation

24

Gas Line Installation

24

Gas Pipe Pressure Testing

24

Aeration Adjustment

25

Brick Panels

25

Log Set Installation

26

Standard Flush Door

27

Flush Louvers

27

Double Screen Doors

27

Optional Bay Door

28

Bay Louvers

28

Full Screen doors

29

Wiring Diagrams

32

Normal Operating Sounds Of Gas Appliances

36

Shutdown Procedure

36

First Fire

36

Maintenance Instructions

36

Gold-Plated Louvers

37

Log Replacement

37

Thermopile / Thermocouple

37

Glass Replacement

37

Door Glass

37

Removing The Fan

38

Replacing The Fan

38

Removing Valve

38

Installing Valve

39

PARTS LIST

 

Main Assembly

40

Burner & Log Assembly

41

Flush Door & Louvers

42

Bay Front & Louvers

43

WARRANTY

 

Warranty

47

Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace

3

Image 3
Contents 918-523a 03/06/08 P42 Gas FireplaceTo the New Owner Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Copy of Safety Decal for P42 Safety LabelMA Code CO Detector RequirementsImportant Message Save These Instructions InstallationGeneral Safety Information Installation ChecklistOptional Heat Release KIT Unit Specifications Locating Your GAS FireplaceManufactured Mobile Home Additional Requirements Heatwave Optional Duct System KITMantel LEG Clearances ClearancesmantelsVent Restrictor TOP Assembly Nailing StripsFraming Finishing Venting IntroductionExterior Vent Termination Requirements Run of 4 feet VentingDescription 6-5/8 Rigid Pipe Cross Reference Chart6-5/8 Rigid Pipe Cross Reference Chart Termination Caps Rigid Pipe VentingAlternate HorizontalVent guard may be required, check local codes Rigid Pipe Venting Arrangements Horizontal Terminations8 outer diameter Regency Flex Vent 4 inner diameter For All Horizontal TerminationsPropane & Natural Gas Rigid Pipe Venting Arrangements Vertical TerminationsVent restrictor #6 must be used Alternate Approved Caps Vertical Termination With CO-LINEAR Flex SystemRequired Parts DescriptionVenting Arrangements Vertical Terminations Below Grade Installation Horizontal TerminationsSnorkel Terminations Vertical Terminations DiagramInstallation Procedures Offset ChartFor Regency Direct Vent System Flex System Data GAS Line InstallationGAS Pipe Pressure Testing High ElevationFront Aeration Brick Panels AdjustmentConditions may occur if the panels Are brokenLOG SET Installation Natural GASPropane Standard Flush Door Flush LouversDouble Screen Doors Optional BAY Door BAY LouversOptional Bay Trim Full Screen Doors Full Screen Door Frame InstallationHinge Location Bottom Grill Hinge Screen Door Wiring Diagrams Any circumstances Live until the fan is installedDo not cut the ground terminal off under For Propane Units and Units Equipped with DC Spark Boxes Operating Instructions Wall SwitchLighting Procedure Thermostat Wire TableCopy of the Lighting Plate Instructions For Your Safety Read Before LightingFirst Fire MaintenanceShutdown Procedure Maintenance InstructionsDoor Glass GOLD-PLATEDGLASS Louvers ReplacementLOG Replacement Thermopile ThermocoupleRemoving the FAN Replacing the FAN Shut the power offInstalling Valve P42 Main Assembly Parts ListP42 Burner & LOG Assembly P42 Flush Door & Louvers P42 BAY Front & Louvers Regency P42-4 Zero Clearance Direct Vent Gas Fireplace Regency P42-4 Zero Clearance Direct Vent Gas Fireplace Regency P42-4 Zero Clearance Direct Vent Gas Fireplace Conditions WarrantyInstaller Please complete the following information

P42-LP4, P42-NG4 specifications

The Regency P42-LP4 and P42-NG4 are two exceptional gas fireplace models that beautifully combine functionality and aesthetic appeal, making them ideal for various home settings. Built with durability and efficiency in mind, these models are equipped with advanced features that enhance user experience.

One of the main highlights of the P42 series is its impressive heating capacity. Both the P42-LP4 and P42-NG4 are designed to deliver substantial warmth, ensuring that spaces of different sizes can be comfortably heated. With a maximum input of up to 40,000 BTUs, these units can effectively warm large living areas, making them perfect for modern homes.

In terms of design, the P42 models boast a sleek and contemporary look. They feature a large viewing area that allows for an expansive flame presentation, inviting warmth and ambiance into your home. The optional polished or brushed stainless steel front and various media options, including glass rocks or logs, provide customization, allowing homeowners to tailor the look of their fireplace to match their personal style and existing decor.

The technologies integrated into the Regency P42-LP4 and P42-NG4 are notable. Both models come equipped with system safety features, ensuring peace of mind. Additionally, they support the use of a programmable remote control, making adjustments to the temperature and flame appearance effortless while allowing homeowners to maintain comfort with just a click.

Efficiency is another key characteristic. These gas fireplaces highlight energy efficiency, designed to maximize heat output while minimizing fuel consumption. They have received high-efficiency ratings, which may qualify users for rebates or incentives in many regions, aligning with the growing demand for eco-friendly home heating solutions.

Installation flexibility is another advantage, with options for direct vent systems allowing for installation in various orientations and settings. This ensures homeowners can enjoy an attractive fireplace without needing extensive renovations or structural changes.

In conclusion, the Regency P42-LP4 and P42-NG4 are standout choices for anyone seeking a powerful, efficient, and stylish gas fireplace. With their innovative technologies, customizable features, and remarkable heating capabilities, these models offer an ideal focal point and cozy environment for any living space. They embody the perfect blend of modern design and traditional warmth, making them an excellent investment for enhancing home comfort and elegance.