Regency P42-LP4 Aeration Brick Panels Adjustment, Conditions may occur if the panels, Are broken

Page 25

INSTALLATION

AERATION

BRICK PANELS

ADJUSTMENT

The aeration adjustment gears are located on the valve mounting plate and are accessed from underneath through the bottom louver opening.

To access the air shutter loosen the lock nut and then use the allen key to turn the turning gear which will adjust the air shutter. Open the air shutter for a blue fl ame or close it for a yellower

ame. Tighten the lock nut when adjustment is complete. The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude.

CAUTION: Carbon will be produced if air shutter is closed too much. (Should be 3/16"(4mm) open for natural gas and 1/2" (13mm) for propane.)

Note: Aeration Adjustment should only be performedbyanauthorizedRegency® Installer at the time of installation or service.

1)Unhook the 2 spring loaded hooks from the bottom of the fl ush door and lift the Flush Front off the unit.

2)Unwrap the brick pattern panels from the protective wrapping. Handle the panels with care as they can break easily.

Note: The logs must not be in the unit.

3)Remove the metal channel from the fi rebox top, and use it later for installing the top brick panel (refer to Diagram 1).

Metal

Channel

Diagram 1

4)Insert the back brick panel fi rst by carefully slipping it between the back wall of the fi rebox and the rear log bracket.

5)Insert the side panels. Tilt them in towards the middle of the fi rebox and put the bottom front corner in fi rst. Be very careful not to scratch them on the firebox hardware. Place them fl at up against the wall, they should fi t snugly against the top of the fi rebox.

6)Rest the narrow end of the top brick panel on top of the back wall brick panel. Then, with both hands, lift the top panel up.

7)Slot the top metal channel 1/2 way into place onto the top of the panel.

8)Carefully position and push the top panel into position. Make sure the tabs of the metal channel fi t into the baffle openings (refer to Diagram 2). Push downwards to secure the channel and top panel.

Tab

Tab

Diagram 2

9)Ensure all panels are securely in place (refer to Diagram 3).

Diagram 3

(front)

IMPORTANT: Dangerous operating

 

conditions may occur if the panels

 

are broken.

(back)

Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace

25

Image 25
Contents 918-523a 03/06/08 P42 Gas FireplaceTo the New Owner Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Copy of Safety Decal for P42 Safety LabelMA Code CO Detector RequirementsGeneral Safety Information InstallationInstallation Checklist Important Message Save These InstructionsManufactured Mobile Home Additional Requirements Unit Specifications Locating Your GAS FireplaceHeatwave Optional Duct System KIT Optional Heat Release KITMantel LEG Clearances ClearancesmantelsFraming Finishing TOP Assembly Nailing StripsVenting Introduction Vent RestrictorExterior Vent Termination Requirements Run of 4 feet VentingDescription 6-5/8 Rigid Pipe Cross Reference Chart6-5/8 Rigid Pipe Cross Reference Chart Alternate Rigid Pipe VentingHorizontal Termination CapsVent guard may be required, check local codes Rigid Pipe Venting Arrangements Horizontal Terminations8 outer diameter Regency Flex Vent 4 inner diameter For All Horizontal TerminationsPropane & Natural Gas Rigid Pipe Venting Arrangements Vertical TerminationsVent restrictor #6 must be used Required Parts Vertical Termination With CO-LINEAR Flex SystemDescription Alternate Approved CapsVenting Arrangements Vertical Terminations Horizontal Terminations Below Grade InstallationSnorkel Terminations Vertical Terminations DiagramOffset Chart Installation ProceduresFor Regency Direct Vent System Flex GAS Pipe Pressure Testing GAS Line InstallationHigh Elevation System DataConditions may occur if the panels Aeration Brick Panels AdjustmentAre broken FrontNatural GAS LOG SET InstallationPropane Flush Louvers Standard Flush DoorDouble Screen Doors BAY Louvers Optional BAY DoorOptional Bay Trim Full Screen Doors Full Screen Door Frame InstallationHinge Location Bottom Grill Hinge Screen Door Any circumstances Live until the fan is installed Wiring DiagramsDo not cut the ground terminal off under For Propane Units and Units Equipped with DC Spark Boxes Lighting Procedure Wall SwitchThermostat Wire Table Operating InstructionsCopy of the Lighting Plate Instructions For Your Safety Read Before LightingShutdown Procedure MaintenanceMaintenance Instructions First FireLOG Replacement GOLD-PLATEDGLASS Louvers ReplacementThermopile Thermocouple Door GlassRemoving the FAN Replacing the FAN Shut the power offInstalling Valve P42 Main Assembly Parts ListP42 Burner & LOG Assembly P42 Flush Door & Louvers P42 BAY Front & Louvers Regency P42-4 Zero Clearance Direct Vent Gas Fireplace Regency P42-4 Zero Clearance Direct Vent Gas Fireplace Regency P42-4 Zero Clearance Direct Vent Gas Fireplace Conditions WarrantyInstaller Please complete the following information

P42-LP4, P42-NG4 specifications

The Regency P42-LP4 and P42-NG4 are two exceptional gas fireplace models that beautifully combine functionality and aesthetic appeal, making them ideal for various home settings. Built with durability and efficiency in mind, these models are equipped with advanced features that enhance user experience.

One of the main highlights of the P42 series is its impressive heating capacity. Both the P42-LP4 and P42-NG4 are designed to deliver substantial warmth, ensuring that spaces of different sizes can be comfortably heated. With a maximum input of up to 40,000 BTUs, these units can effectively warm large living areas, making them perfect for modern homes.

In terms of design, the P42 models boast a sleek and contemporary look. They feature a large viewing area that allows for an expansive flame presentation, inviting warmth and ambiance into your home. The optional polished or brushed stainless steel front and various media options, including glass rocks or logs, provide customization, allowing homeowners to tailor the look of their fireplace to match their personal style and existing decor.

The technologies integrated into the Regency P42-LP4 and P42-NG4 are notable. Both models come equipped with system safety features, ensuring peace of mind. Additionally, they support the use of a programmable remote control, making adjustments to the temperature and flame appearance effortless while allowing homeowners to maintain comfort with just a click.

Efficiency is another key characteristic. These gas fireplaces highlight energy efficiency, designed to maximize heat output while minimizing fuel consumption. They have received high-efficiency ratings, which may qualify users for rebates or incentives in many regions, aligning with the growing demand for eco-friendly home heating solutions.

Installation flexibility is another advantage, with options for direct vent systems allowing for installation in various orientations and settings. This ensures homeowners can enjoy an attractive fireplace without needing extensive renovations or structural changes.

In conclusion, the Regency P42-LP4 and P42-NG4 are standout choices for anyone seeking a powerful, efficient, and stylish gas fireplace. With their innovative technologies, customizable features, and remarkable heating capabilities, these models offer an ideal focal point and cozy environment for any living space. They embody the perfect blend of modern design and traditional warmth, making them an excellent investment for enhancing home comfort and elegance.