Regency P42-LP4, P42-NG4 installation manual Venting, Run of 4 feet

Page 11

INSTALLATION

VENTING

Regency® Direct Vent System (Flex) Horizontal Terminations Only

These venting systems, in combination with the P42 Direct Vent Gas

1)

6-7/8" dia. fl exible liner (4 ft. length)

Fireplace, have been tested and listed as a direct vent heater system

2)

4" dia. fl exible liner (4 ft. length)

by Warnock Hersey. The location of the termination cap must conform to

3)

spring spacers (4)

the requirements in the Vent Terminal Locations diagram in the "Exterior

4)

thimble (2)

Vent Termination Locations" section.

5)

AstroCap termination cap (1)

 

6)

screws (12)

Regency® Direct Vent (Flex) System Termination Kit (Part # 946-515)

7)

tube of Mill Pac (1)

includes all the parts needed to install the P42 with a maximum

8)

plated screws (8)

run of 4 feet.

9)

screws #8 x 1/2" Drill Point, stainless steel (4)

Wall Thimble (2 pc)

4" (102mm)

AstroCap

dia. flue pipe

Termination Cap

6-7/8"

Part #946-523/P

 

(173mm) dia.

spring

Flue pipe

spacer

 

If longer runs are needed, the Regency® Direct Vent system (Flex)

#946-516 includes all the parts needed to install the P42 with a maximum 10' run.

1)6-7/8" dia. fl exible liner (10 ft. length)

2)4" dia. fl exible liner (10 ft. length)

3)spring spacers (7)

4)thimble (2)

5)AstroCap termination cap (1)

6)screws (12)

7)tube of Mill Pac (1)

8)plated screws (8)

9)screws #8 x 1/2" Drill Point, stainless steel (4)

Note:

a)Liner sections should be continuous without any joints or seams.

b)Only Flex pipe purchased from Regency® may be used for Flex Installations.

Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace

11

Image 11
Contents 918-523a 03/06/08 P42 Gas FireplaceTo the New Owner Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Copy of Safety Decal for P42 Safety LabelMA Code CO Detector RequirementsImportant Message Save These Instructions InstallationGeneral Safety Information Installation ChecklistOptional Heat Release KIT Unit Specifications Locating Your GAS FireplaceManufactured Mobile Home Additional Requirements Heatwave Optional Duct System KITMantel LEG Clearances ClearancesmantelsVent Restrictor TOP Assembly Nailing StripsFraming Finishing Venting IntroductionExterior Vent Termination Requirements Run of 4 feet VentingDescription 6-5/8 Rigid Pipe Cross Reference Chart6-5/8 Rigid Pipe Cross Reference Chart Termination Caps Rigid Pipe VentingAlternate HorizontalVent guard may be required, check local codes Rigid Pipe Venting Arrangements Horizontal Terminations8 outer diameter Regency Flex Vent 4 inner diameter For All Horizontal TerminationsPropane & Natural Gas Rigid Pipe Venting Arrangements Vertical TerminationsVent restrictor #6 must be used Alternate Approved Caps Vertical Termination With CO-LINEAR Flex SystemRequired Parts DescriptionVenting Arrangements Vertical Terminations Snorkel Terminations Below Grade InstallationHorizontal Terminations Vertical Terminations DiagramFor Regency Direct Vent System Flex Installation ProceduresOffset Chart System Data GAS Line InstallationGAS Pipe Pressure Testing High ElevationFront Aeration Brick Panels AdjustmentConditions may occur if the panels Are brokenPropane LOG SET InstallationNatural GAS Double Screen Doors Standard Flush DoorFlush Louvers Optional Bay Trim Optional BAY DoorBAY Louvers Full Screen Doors Full Screen Door Frame InstallationHinge Location Bottom Grill Hinge Screen Door Do not cut the ground terminal off under Wiring DiagramsAny circumstances Live until the fan is installed For Propane Units and Units Equipped with DC Spark Boxes Operating Instructions Wall SwitchLighting Procedure Thermostat Wire TableCopy of the Lighting Plate Instructions For Your Safety Read Before LightingFirst Fire MaintenanceShutdown Procedure Maintenance InstructionsDoor Glass GOLD-PLATEDGLASS Louvers ReplacementLOG Replacement Thermopile ThermocoupleRemoving the FAN Replacing the FAN Shut the power offInstalling Valve P42 Main Assembly Parts ListP42 Burner & LOG Assembly P42 Flush Door & Louvers P42 BAY Front & Louvers Regency P42-4 Zero Clearance Direct Vent Gas Fireplace Regency P42-4 Zero Clearance Direct Vent Gas Fireplace Regency P42-4 Zero Clearance Direct Vent Gas Fireplace Conditions WarrantyInstaller Please complete the following information

P42-LP4, P42-NG4 specifications

The Regency P42-LP4 and P42-NG4 are two exceptional gas fireplace models that beautifully combine functionality and aesthetic appeal, making them ideal for various home settings. Built with durability and efficiency in mind, these models are equipped with advanced features that enhance user experience.

One of the main highlights of the P42 series is its impressive heating capacity. Both the P42-LP4 and P42-NG4 are designed to deliver substantial warmth, ensuring that spaces of different sizes can be comfortably heated. With a maximum input of up to 40,000 BTUs, these units can effectively warm large living areas, making them perfect for modern homes.

In terms of design, the P42 models boast a sleek and contemporary look. They feature a large viewing area that allows for an expansive flame presentation, inviting warmth and ambiance into your home. The optional polished or brushed stainless steel front and various media options, including glass rocks or logs, provide customization, allowing homeowners to tailor the look of their fireplace to match their personal style and existing decor.

The technologies integrated into the Regency P42-LP4 and P42-NG4 are notable. Both models come equipped with system safety features, ensuring peace of mind. Additionally, they support the use of a programmable remote control, making adjustments to the temperature and flame appearance effortless while allowing homeowners to maintain comfort with just a click.

Efficiency is another key characteristic. These gas fireplaces highlight energy efficiency, designed to maximize heat output while minimizing fuel consumption. They have received high-efficiency ratings, which may qualify users for rebates or incentives in many regions, aligning with the growing demand for eco-friendly home heating solutions.

Installation flexibility is another advantage, with options for direct vent systems allowing for installation in various orientations and settings. This ensures homeowners can enjoy an attractive fireplace without needing extensive renovations or structural changes.

In conclusion, the Regency P42-LP4 and P42-NG4 are standout choices for anyone seeking a powerful, efficient, and stylish gas fireplace. With their innovative technologies, customizable features, and remarkable heating capabilities, these models offer an ideal focal point and cozy environment for any living space. They embody the perfect blend of modern design and traditional warmth, making them an excellent investment for enhancing home comfort and elegance.