Regency P42-NG4, P42-LP4 installation manual Clearancesmantels, Mantel LEG Clearances

Page 8

INSTALLATION

CLEARANCESMANTELS

The clearances listed below are Minimum distances unless otherwise stated:

A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions.

Clearance to Combustibles from:

Back 0" (0mm)

Side 0" (0mm)

Floor 0" (0mm)

Minimum Clearance from Louver to:

Mantel

min. 7"

(177mm)

 

Ceiling

36"

(914mm) from top

 

 

 

 

 

 

 

of louvers

 

Side Wall

6"

 

(152mm)

 

Vent

1-1/2"

(38mm) Flex

 

 

 

 

 

1-1/4"

(32mm) Rigid Pipe

 

Alcove Clearances:

 

 

 

 

 

 

 

 

Max. Depth

36"

(914mm)

 

Min. Width

52"

(1321mm)

 

Min. Height

90"

(2286mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARNING

Fire hazard is an extreme risk

if these clearances are

not adhered to.

The HeatWave Duct Kit

and the Heat Release Kit have different clearance and framing

Heat Release Kit requirements, check the HeatWaveand Heat

Release manual for details.

Because of the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from louver are shown in the diagram below.

Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible board.

This drawing is to scale at 1:6 (one inch = 6 inches)

Mantel can be installed anywhere in shaded area using the above scale for units with the Flush Front and with the optional Bay Front.

Note: Ensure the paint that is used on the mantel and the facing is "heat resistant" or the paint may discolour.

MANTEL LEG CLEARANCES

Combustible mantel leg clearances as per diagram below:

Maximum

1-1/2" projection at 2" minimum clearance.

8

Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace

Image 8
Contents P42 Gas Fireplace 918-523a 03/06/08Information for MOBILE/MANUFACTURED Homes After First Sale To the New OwnerTable of Contents Safety Label Copy of Safety Decal for P42Requirements MA Code CO DetectorInstallation General Safety InformationInstallation Checklist Important Message Save These InstructionsUnit Specifications Locating Your GAS Fireplace Manufactured Mobile Home Additional RequirementsHeatwave Optional Duct System KIT Optional Heat Release KITClearancesmantels Mantel LEG ClearancesTOP Assembly Nailing Strips Framing FinishingVenting Introduction Vent RestrictorExterior Vent Termination Requirements Venting Run of 4 feet6-5/8 Rigid Pipe Cross Reference Chart Description6-5/8 Rigid Pipe Cross Reference Chart Rigid Pipe Venting AlternateHorizontal Termination CapsRigid Pipe Venting Arrangements Horizontal Terminations Vent guard may be required, check local codesFor All Horizontal Terminations 8 outer diameter Regency Flex Vent 4 inner diameterRigid Pipe Venting Arrangements Vertical Terminations Propane & Natural GasVent restrictor #6 must be used Vertical Termination With CO-LINEAR Flex System Required PartsDescription Alternate Approved CapsVenting Arrangements Vertical Terminations Snorkel Terminations Below Grade InstallationHorizontal Terminations Diagram Vertical TerminationsFor Regency Direct Vent System Flex Installation ProceduresOffset Chart GAS Line Installation GAS Pipe Pressure TestingHigh Elevation System DataAeration Brick Panels Adjustment Conditions may occur if the panelsAre broken FrontPropane LOG SET InstallationNatural GAS Double Screen Doors Standard Flush DoorFlush Louvers Optional Bay Trim Optional BAY DoorBAY Louvers Full Screen Door Frame Installation Full Screen DoorsHinge Location Bottom Grill Hinge Screen Door Do not cut the ground terminal off under Wiring DiagramsAny circumstances Live until the fan is installed For Propane Units and Units Equipped with DC Spark Boxes Wall Switch Lighting ProcedureThermostat Wire Table Operating InstructionsFor Your Safety Read Before Lighting Copy of the Lighting Plate InstructionsMaintenance Shutdown ProcedureMaintenance Instructions First FireGOLD-PLATEDGLASS Louvers Replacement LOG ReplacementThermopile Thermocouple Door GlassShut the power off Removing the FAN Replacing the FANInstalling Valve Parts List P42 Main AssemblyP42 Burner & LOG Assembly P42 Flush Door & Louvers P42 BAY Front & Louvers Regency P42-4 Zero Clearance Direct Vent Gas Fireplace Regency P42-4 Zero Clearance Direct Vent Gas Fireplace Regency P42-4 Zero Clearance Direct Vent Gas Fireplace Warranty ConditionsInstaller Please complete the following information

P42-LP4, P42-NG4 specifications

The Regency P42-LP4 and P42-NG4 are two exceptional gas fireplace models that beautifully combine functionality and aesthetic appeal, making them ideal for various home settings. Built with durability and efficiency in mind, these models are equipped with advanced features that enhance user experience.

One of the main highlights of the P42 series is its impressive heating capacity. Both the P42-LP4 and P42-NG4 are designed to deliver substantial warmth, ensuring that spaces of different sizes can be comfortably heated. With a maximum input of up to 40,000 BTUs, these units can effectively warm large living areas, making them perfect for modern homes.

In terms of design, the P42 models boast a sleek and contemporary look. They feature a large viewing area that allows for an expansive flame presentation, inviting warmth and ambiance into your home. The optional polished or brushed stainless steel front and various media options, including glass rocks or logs, provide customization, allowing homeowners to tailor the look of their fireplace to match their personal style and existing decor.

The technologies integrated into the Regency P42-LP4 and P42-NG4 are notable. Both models come equipped with system safety features, ensuring peace of mind. Additionally, they support the use of a programmable remote control, making adjustments to the temperature and flame appearance effortless while allowing homeowners to maintain comfort with just a click.

Efficiency is another key characteristic. These gas fireplaces highlight energy efficiency, designed to maximize heat output while minimizing fuel consumption. They have received high-efficiency ratings, which may qualify users for rebates or incentives in many regions, aligning with the growing demand for eco-friendly home heating solutions.

Installation flexibility is another advantage, with options for direct vent systems allowing for installation in various orientations and settings. This ensures homeowners can enjoy an attractive fireplace without needing extensive renovations or structural changes.

In conclusion, the Regency P42-LP4 and P42-NG4 are standout choices for anyone seeking a powerful, efficient, and stylish gas fireplace. With their innovative technologies, customizable features, and remarkable heating capabilities, these models offer an ideal focal point and cozy environment for any living space. They embody the perfect blend of modern design and traditional warmth, making them an excellent investment for enhancing home comfort and elegance.