Regency P42-LP4 Copy of the Lighting Plate Instructions, For Your Safety Read Before Lighting

Page 35

OPERATING INSTRUCTIONS

COPY OF THE LIGHTING PLATE INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1/

NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1. (Australia: AS5601-2004, New Zealand: NZS 5261)

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or gas supplier.

A)This appliance has a pilot which must be lighted by hand, following the instructions below exactly.

B)BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

-Do not try to light any appliance

-Do not touch any electric switch, do not use any phone in your building

-Immediately call your gas supplier from a neighbors phone. Follow the gas supplier’s instructions.

-If you cannot reach your gas supplier, call the fire department.

C)Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D)Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

E)This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air.

CAUTION: Hot while in operation. Do not touch. Severe Burns may result. Due to high surface temperatures keep children, clothing and furniture, gasoline and other liquids having fammable vapors away. Keep burner and control compartment clean. See installation and operating instructions accompanying appliance.

LIGHTING INSTRUCTIONS

STOP! Read the safety information above on this label.

FOR UNITS NOT EQUIPPED WITH ELECTRIC SPARK:

1) Push in gas control knob slightly and turn clockwise

to

“OFF”. Knob cannot

be turned from “PILOT” to “OFF” unless

knob is pushed in slightly. Do not force.

 

PILOT BURNER

 

OFF

VEILLEUSE

 

 

THERMOPILE

Gas Inlet

 

ELEMENT

 

 

THERMO-

 

 

ELECTRIQUE

 

 

2)Wait five (5) minutes to clear out any gas. If you then smell gas STOP! follow “B” in the safety information above on this label. If you don’t smell gas, go to the next step.

3)Turn knob on gas control counterclockwise to “PILOT”.

4)Push in control knob all the way and hold in. Immediately push black button on spark igniter until pilot lights. Continue to hold the control knob in for about 1/2 minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 3) and 4).

If knob does not pop up when released, stop and immediately call your service technician or gas supplier.

If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier.

5)Turn gas control knob counterclockwise to “ON”.

6)Use rocker switch to operate main burner.

FOR ALL PROPANE UNITS AND

UNITS EQUIPPED WITH ELECTRIC SPARK BOXES:

1)Push in gas control knob slightly and turn to “PILOT” position.

2)Push in control knob all the way and hold in until the pilot lights up. Continue to hold the control knob in for about 20 seconds after the pilot is lit. Release knob.

3)Push in gas control knob slightly and turn to "ON" position.

4)Turn ON the flame switch.

Gas Inlet

TO TURN OFF GAS APPLIANCE

1)Turn off the flame switch .

2)Push in the gas control knob slightly and turn clockwise to “OFF” . Do not force .

3)Turn off all electric power to the appliance if service is to be performed .

You may shut off the pilot during prolonged non use periods to conserve fuel .

DO NOT REMOVE THIS INSTRUCTION PLATE

918-474a

Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace

35

Image 35
Contents 918-523a 03/06/08 P42 Gas FireplaceTo the New Owner Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Copy of Safety Decal for P42 Safety LabelMA Code CO Detector RequirementsImportant Message Save These Instructions InstallationGeneral Safety Information Installation ChecklistOptional Heat Release KIT Unit Specifications Locating Your GAS FireplaceManufactured Mobile Home Additional Requirements Heatwave Optional Duct System KITMantel LEG Clearances ClearancesmantelsVent Restrictor TOP Assembly Nailing StripsFraming Finishing Venting IntroductionExterior Vent Termination Requirements Run of 4 feet VentingDescription 6-5/8 Rigid Pipe Cross Reference Chart6-5/8 Rigid Pipe Cross Reference Chart Termination Caps Rigid Pipe VentingAlternate HorizontalVent guard may be required, check local codes Rigid Pipe Venting Arrangements Horizontal Terminations8 outer diameter Regency Flex Vent 4 inner diameter For All Horizontal TerminationsPropane & Natural Gas Rigid Pipe Venting Arrangements Vertical TerminationsVent restrictor #6 must be used Alternate Approved Caps Vertical Termination With CO-LINEAR Flex SystemRequired Parts DescriptionVenting Arrangements Vertical Terminations Snorkel Terminations Below Grade InstallationHorizontal Terminations Vertical Terminations DiagramFor Regency Direct Vent System Flex Installation ProceduresOffset Chart System Data GAS Line InstallationGAS Pipe Pressure Testing High ElevationFront Aeration Brick Panels AdjustmentConditions may occur if the panels Are brokenPropane LOG SET InstallationNatural GAS Double Screen Doors Standard Flush DoorFlush Louvers Optional Bay Trim Optional BAY DoorBAY Louvers Full Screen Doors Full Screen Door Frame InstallationHinge Location Bottom Grill Hinge Screen Door Do not cut the ground terminal off under Wiring DiagramsAny circumstances Live until the fan is installed For Propane Units and Units Equipped with DC Spark Boxes Operating Instructions Wall SwitchLighting Procedure Thermostat Wire TableCopy of the Lighting Plate Instructions For Your Safety Read Before LightingFirst Fire MaintenanceShutdown Procedure Maintenance InstructionsDoor Glass GOLD-PLATEDGLASS Louvers ReplacementLOG Replacement Thermopile ThermocoupleRemoving the FAN Replacing the FAN Shut the power offInstalling Valve P42 Main Assembly Parts ListP42 Burner & LOG Assembly P42 Flush Door & Louvers P42 BAY Front & Louvers Regency P42-4 Zero Clearance Direct Vent Gas Fireplace Regency P42-4 Zero Clearance Direct Vent Gas Fireplace Regency P42-4 Zero Clearance Direct Vent Gas Fireplace Conditions WarrantyInstaller Please complete the following information

P42-LP4, P42-NG4 specifications

The Regency P42-LP4 and P42-NG4 are two exceptional gas fireplace models that beautifully combine functionality and aesthetic appeal, making them ideal for various home settings. Built with durability and efficiency in mind, these models are equipped with advanced features that enhance user experience.

One of the main highlights of the P42 series is its impressive heating capacity. Both the P42-LP4 and P42-NG4 are designed to deliver substantial warmth, ensuring that spaces of different sizes can be comfortably heated. With a maximum input of up to 40,000 BTUs, these units can effectively warm large living areas, making them perfect for modern homes.

In terms of design, the P42 models boast a sleek and contemporary look. They feature a large viewing area that allows for an expansive flame presentation, inviting warmth and ambiance into your home. The optional polished or brushed stainless steel front and various media options, including glass rocks or logs, provide customization, allowing homeowners to tailor the look of their fireplace to match their personal style and existing decor.

The technologies integrated into the Regency P42-LP4 and P42-NG4 are notable. Both models come equipped with system safety features, ensuring peace of mind. Additionally, they support the use of a programmable remote control, making adjustments to the temperature and flame appearance effortless while allowing homeowners to maintain comfort with just a click.

Efficiency is another key characteristic. These gas fireplaces highlight energy efficiency, designed to maximize heat output while minimizing fuel consumption. They have received high-efficiency ratings, which may qualify users for rebates or incentives in many regions, aligning with the growing demand for eco-friendly home heating solutions.

Installation flexibility is another advantage, with options for direct vent systems allowing for installation in various orientations and settings. This ensures homeowners can enjoy an attractive fireplace without needing extensive renovations or structural changes.

In conclusion, the Regency P42-LP4 and P42-NG4 are standout choices for anyone seeking a powerful, efficient, and stylish gas fireplace. With their innovative technologies, customizable features, and remarkable heating capabilities, these models offer an ideal focal point and cozy environment for any living space. They embody the perfect blend of modern design and traditional warmth, making them an excellent investment for enhancing home comfort and elegance.