Regency P42-LP4, P42-NG4 installation manual 6-5/8 Rigid Pipe Cross Reference Chart

Page 13

INSTALLATION

4” x 6-5/8” Rigid Pipe Cross Reference Chart (Cont.)

Components from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI.

Description

Simpson

Simpson

Selkirk

American Metal

Metal-Fab®

Security

Direct Vent GS®

Products

®

Direct Vent Pro®

Discontinued

Direct-Temp™

 

Sure Seal

Secure Vent®

 

 

 

Amerivent Direct

 

 

Attic Insulation Shield 12”

46DVA-IS - N/A from FPI

N/A

N/A

4DAIS12

 

N/A

SV4RSA

Attic Insulation Shield - Cold Climates 36”

N/A

N/A

N/A

4DAIS36

 

N/A

N/A

Basic Horizontal Termination Kit (A)

Horizontal Termination Kit (B)

Vertical Termination Kit

DISC. 46DVA-KHA (Changed Components) DISC.

970

971

978

4DT-HKA

4DT-HKB

4DT-VKC

4DHTK2

4DHTK1

4DVTK

4DHTKA

4DHTKB

4DVTK

SV - SHK

SV - HK

SV - FK

High Wind Vertical Cap

High Wind Horizontal Cap

Horizontal Square Termination Cap

Vertical Termination Cap

Storm Collar

46DVA-VCH

46DVA-HC

Disc - See 46DVA-HC 46DVA-VC 46DVA-SC

991

985

984

980

953

N/A

N/A 4DT-HHC 4DT-HVC 4DT-SC

N/A

N/A

4DHC

4DVC

4DSC

N/A

N/A

4DHT

4DVT

4DSC

N/A

N/A SV4CHC-1 SV4CGV-1 SV4FC

Adjustable Flashing, 0/12-6/12 Adjustable Flashing, 6/12-12/12

46DVA-F6 46DVA-F12

943

943S

4DT-AF6 4DT-AF12

4DF

4DF12

4DF 4DF-12

SV4FA

SV4FB

Vinyl Siding Standoff Vinyl Siding Shield Plate

46DVA-VSS N/A

950

N/A

4DT-VS 4DT-VSP

N/A

N/A

4DVS

N/A

SV4VS

SV4VS

Snorkel Termination 14” Snorkel Termination 36”

46DVA-SNK14 N/A

982

981

4DT-ST14 4DT-ST36

4D12S

4D36S

4DST14

4DST36

SV4STC14

SV4STC36

Restrictor Disk

Extended Vertical Termination Cap

Chimney Conversion Kit A

Chimney Conversion Kit B

Chimney Conversion Kit C

Chimney Conversion Kit Masonry

Mansonry Chimney Conversion Kit

(includes: Cap Adapter 18”x18” Flashing)

Wall Firestop

Colinear Flex Connectors

46DVA-RD 46DVA-VCE 46DVA-KCA 46DVA-KCB 46DVA-KCC 46DVA-KMC

46DVA-KCT

46DVA-WFS 46DVA-ADF

929

930

931

932

933

934

935

947

923F

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

FPI

946-506/P

Vent Guard (Optional) for AstropCap

946-205

Vinyl Siding Shield for Riser Vent Terminal

510-994

Rigid Pipe Adapter (Must use with all Rigid Piping)

946-208/P

Vent Guard (Optional) for Riser Vent Terminal

640-530/P

Riser Vent Terminal

946-523/P

AstroCap Horizontal Cap

 

 

946-206

Vinyl Siding Standoff for AstroCap

 

 

 

 

*NOTE: When using Metal-Fab Sure Seal Rigid Piping please note that either the Adaptor (4DDA) or 90º Starter Elbow (4D90A) must be used in conjunction with FPI Rigid Pipe Adaptor (510-994).

Offset Pipe Selection:

Use this table to determine offset pipe lengths.

Pipe Length

4” x 6-5/8” Venting

 

 

Run (X)

Rise (Y)

 

 

 

 

0”(0mm)

4-7/8”(124mm)

13-3/8”(340mm)

 

 

 

6”(152mm)

8”(203mm)

16-1/2”(419mm)

 

 

 

9”(229mm)

10-1/8”(257mm)

18-5/8”(473mm)

 

 

 

12”(305mm)

12-1/4”(311mm)

20-3/4”(527mm)

 

 

 

24”(610mm)

20-5/8”(524mm)

29-1/8”(740mm)

 

 

 

36”(914mm)

29”(737mm)

37-1/2”(953mm)

 

 

 

48”(1219mm)

37-7/16”(951mm)

45-15/16”(1167mm)

 

 

 

L

X

Y

For specific instructions or details on particular venting components please visit the following websites:

Simpson Direct Vent Pro: www.duravent.com

Selkirk Direct-Temp: www.selkirkcorp.com

American Metal Products Amerivent Direct: www.americanmetalproducts.com

Metal-Fab Sure Seal: www.mtlfab.com

Security Secure Vent: www.securitychimneys.com

NOTE: Horizontal runs of vent must be level, or have a 1/4 inch rise for every 1 foot of run towards the termination. Never allow the vent to run downward. This could cause high temperatures and may present a possible fire hazard.

Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace

13

Image 13
Contents 918-523a 03/06/08 P42 Gas FireplaceTo the New Owner Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Copy of Safety Decal for P42 Safety LabelMA Code CO Detector RequirementsGeneral Safety Information InstallationInstallation Checklist Important Message Save These InstructionsManufactured Mobile Home Additional Requirements Unit Specifications Locating Your GAS FireplaceHeatwave Optional Duct System KIT Optional Heat Release KITMantel LEG Clearances ClearancesmantelsFraming Finishing TOP Assembly Nailing StripsVenting Introduction Vent RestrictorExterior Vent Termination Requirements Run of 4 feet VentingDescription 6-5/8 Rigid Pipe Cross Reference Chart6-5/8 Rigid Pipe Cross Reference Chart Alternate Rigid Pipe VentingHorizontal Termination CapsVent guard may be required, check local codes Rigid Pipe Venting Arrangements Horizontal Terminations8 outer diameter Regency Flex Vent 4 inner diameter For All Horizontal TerminationsPropane & Natural Gas Rigid Pipe Venting Arrangements Vertical TerminationsVent restrictor #6 must be used Required Parts Vertical Termination With CO-LINEAR Flex SystemDescription Alternate Approved CapsVenting Arrangements Vertical Terminations Horizontal Terminations Below Grade InstallationSnorkel Terminations Vertical Terminations DiagramOffset Chart Installation ProceduresFor Regency Direct Vent System Flex GAS Pipe Pressure Testing GAS Line InstallationHigh Elevation System DataConditions may occur if the panels Aeration Brick Panels AdjustmentAre broken FrontNatural GAS LOG SET InstallationPropane Flush Louvers Standard Flush DoorDouble Screen Doors BAY Louvers Optional BAY DoorOptional Bay Trim Full Screen Doors Full Screen Door Frame InstallationHinge Location Bottom Grill Hinge Screen Door Any circumstances Live until the fan is installed Wiring DiagramsDo not cut the ground terminal off under For Propane Units and Units Equipped with DC Spark Boxes Lighting Procedure Wall SwitchThermostat Wire Table Operating InstructionsCopy of the Lighting Plate Instructions For Your Safety Read Before LightingShutdown Procedure MaintenanceMaintenance Instructions First FireLOG Replacement GOLD-PLATEDGLASS Louvers ReplacementThermopile Thermocouple Door GlassRemoving the FAN Replacing the FAN Shut the power offInstalling Valve P42 Main Assembly Parts ListP42 Burner & LOG Assembly P42 Flush Door & Louvers P42 BAY Front & Louvers Regency P42-4 Zero Clearance Direct Vent Gas Fireplace Regency P42-4 Zero Clearance Direct Vent Gas Fireplace Regency P42-4 Zero Clearance Direct Vent Gas Fireplace Conditions WarrantyInstaller Please complete the following information

P42-LP4, P42-NG4 specifications

The Regency P42-LP4 and P42-NG4 are two exceptional gas fireplace models that beautifully combine functionality and aesthetic appeal, making them ideal for various home settings. Built with durability and efficiency in mind, these models are equipped with advanced features that enhance user experience.

One of the main highlights of the P42 series is its impressive heating capacity. Both the P42-LP4 and P42-NG4 are designed to deliver substantial warmth, ensuring that spaces of different sizes can be comfortably heated. With a maximum input of up to 40,000 BTUs, these units can effectively warm large living areas, making them perfect for modern homes.

In terms of design, the P42 models boast a sleek and contemporary look. They feature a large viewing area that allows for an expansive flame presentation, inviting warmth and ambiance into your home. The optional polished or brushed stainless steel front and various media options, including glass rocks or logs, provide customization, allowing homeowners to tailor the look of their fireplace to match their personal style and existing decor.

The technologies integrated into the Regency P42-LP4 and P42-NG4 are notable. Both models come equipped with system safety features, ensuring peace of mind. Additionally, they support the use of a programmable remote control, making adjustments to the temperature and flame appearance effortless while allowing homeowners to maintain comfort with just a click.

Efficiency is another key characteristic. These gas fireplaces highlight energy efficiency, designed to maximize heat output while minimizing fuel consumption. They have received high-efficiency ratings, which may qualify users for rebates or incentives in many regions, aligning with the growing demand for eco-friendly home heating solutions.

Installation flexibility is another advantage, with options for direct vent systems allowing for installation in various orientations and settings. This ensures homeowners can enjoy an attractive fireplace without needing extensive renovations or structural changes.

In conclusion, the Regency P42-LP4 and P42-NG4 are standout choices for anyone seeking a powerful, efficient, and stylish gas fireplace. With their innovative technologies, customizable features, and remarkable heating capabilities, these models offer an ideal focal point and cozy environment for any living space. They embody the perfect blend of modern design and traditional warmth, making them an excellent investment for enhancing home comfort and elegance.