Regency P131, P121RC, P121LC installation manual Thermostat Wire Table, Diagram below

Page 31

INSTALLATION

Option 1:

Option 2:

Option 3:

REMOTE CONTROL

WALL SWITCH

WALL THERMOSTAT

Can be used with Option 2 or 3 but not both.

Use the Regency® Remote Control Kit approved for this unit. Use of other systems may void your warranty.

The remote control kit comes with a hand held transmitter, a receiver and a wall mounting plate.

1) Choose a convenient location on the wall

to install the receiver and the receptacle

box (protection from extreme heat is very

important). Run wires from the fi replace

to that location. Use the Thermostat Wire

Table.

Can be used with Option 1 or 3 but not both.

1)Run the supplied 15' of wire through the back gas inlet opening. Be careful not to damage wire.

Note: We recommend a maximum of 15' of wire but if you wish to go with a longer run, use the Thermostat Wire Table.

2)Connect the wire to the supplied wall switch and install into the receptacle box.

Can be used with Option 1 or 2 but not both.

A wall thermostat may be installed if desired, connect the wires as per the wiring diagram. Use the table below to determine the maximum wire length.

Note: Preferable if the thermostat is installed on an interior wall.

Regency® offers an optional programmable thermostat but any 250-750 millivolt rated non- anticipator type thermostat that is CSA, ULC or UL approved may be used.

2) Connect the two wires to the gas valve. See

diagram below.

CAUTION

 

 

Do not connect millivolt all

 

CAUTION

switch wire to a 120V wire.

 

Do not connect millivolt

 

 

wall thermostat wires

 

 

 

to a 120V wire.

 

 

 

CAUTION

Do not connect millivolt remote control wires to a 120V wire.

3)Install 3AAAalkaline batteries in transmitter and 4 AA alkaline batteries in the receiver. Install the receiver and its cover in the wall. Switch the remote receiver to "remote" mode. The remote control is now ready for operation.

Thermostat Wire Table

Recommended Maximum Lead Length

(Two-Wire) When Using Wall

Thermostat (CP-2 System)

Wire Size

Max. Length

 

14 GA.

50

Ft.

 

16 GA.

32

Ft.

 

18 GA.

20

Ft.

 

20 GA.

12

Ft.

 

22 GA.

9

Ft.

 

Regency® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct Vent Gas Fireplace

31

Image 31
Contents P121 / P121LC / P121RC / P131 To the New Owner Manufactured Mobile Home RequirementsTable of Contents Copy of Safety Decal for P121/P121LC/P121RC/P131 Safety LabelMA Code CO Detector RequirementsImportant Message Save These Instructions InstallationGeneral Safety Information Installation ChecklistNon-load bearing SpecificationsP121LC-2 Left Corner Unit Locations see section Exterior Vent Termination Locations Locating Your GAS FireplaceCombustible Mantels ClearancesCorner Unit Framing DimensionsFraming and Finishing P121-2 See Thru P131-2 PierTop Standoff Assembly Unit Assembly Prior to InstallationVenting Introduction VentHeight Meters Minimum Feet RoofPitch Exterior Vent Termination LocationsSV4LB6 Rigid Pipe Venting Components ListVenting Arrangement Horizontal Terminations Horizontal or Vertical Terminations Rigid Pipe Venting SystemsRegency Direct Vent System Flex Propane & Natural Gas Rigid Pipe Venting Arrangements Horizontal TerminationsHorizontal Venting with Three 3 90o Elbows Horizontal Venting with Two 2 90o ElbowsPropane & Natural Gas Rigid Pipe Venting Arrangements Vertical TerminationsVertical Venting with Three 3 90o Elbows Vertical Venting with Two 2 90o ElbowsSet the unit in its desired location. Check Vertical Terminations This allows for small adjustmentsOffset Chart Installation ProceduresFor Regency AstroCapTM Direct Vent System Flex LPG Conversion Kit Contains Qty Conversion KIT #731-969 from NG to LPInstallation of the DC Sparker Ground Wire from Kit High Elevation Pilot AdjustmentGAS Line Installation GAS Pipe Pressure Testing327 329 326 328 LOG Installation327 Louvers & Grills Finishing TrimP121-2 & P131-2 Corner Models Diagram below Thermostat Wire TableDo not cut the ground terminal off under any circumstances Wiring DiagramsTerminal Block Location For Propane Units and Units Equipped with DC Spark BoxesOperating Instructions Shutdown ProcedureFirst Fire Aeration Adjustment Lighting ProcedureCopy of the Lighting Plate Instructions Normal Operating Sounds of GAS AppliancesMaintenance Remove Left & Right Side Base Brick Panels Removing ValveFAN Replacement Installing ValveP121-2 see Thru Main Assembly Parts ListDescription P131-2 Pier Main Assembly 204 225 P121RC-2 Right Corner Main AssemblyP121LC-2 Left Corner Main Assembly P121/P121LC/P121RC/P131-2 Burner Assembly & LOG SET Page Page Page Conditions WarrantyInstaller Please complete the following information
Related manuals
Manual 40 pages 33.79 Kb

P121LC, P121, P121RC, P131 specifications

The Regency P121RC, P121, P131, and P121LC are advanced technological innovations in the realm of heating, ventilation, and air conditioning (HVAC) systems. Designed for both residential and commercial applications, these models are known for their efficiency, reliability, and comfort-enhancing features.

The Regency P121RC is particularly notable for its high-efficiency rating, making it a popular choice for environmentally conscious consumers. With advanced heat pump technology, it provides optimal heating and cooling throughout the year, reducing energy consumption while maintaining a consistent indoor climate. The use of environmentally friendly refrigerants further emphasizes its commitment to sustainability.

The P121 model stands out for its cutting-edge smart technology integration. It is equipped with Wi-Fi connectivity, allowing users to control their HVAC systems remotely via a mobile application. This feature not only enhances convenience but also enables energy management, reducing operational costs through effective scheduling and monitoring.

The P131 model caters to larger spaces, thanks to its robust cooling and heating capabilities. It employs a variable-speed compressor that adjusts to the specific demands of the space, ensuring optimal performance while minimizing noise disruption. This model is also compatible with smart home systems, contributing to a seamless integration of technology within modern living environments.

Meanwhile, the P121LC is designed with energy conservation in mind, featuring a dual-stage heating and cooling system. Its advanced airflow technology ensures even distribution of temperature, promoting overall comfort and reducing the risk of hot or cold spots in a room. Like its counterparts, it supports remote operation through smart technology, offering users full control over their indoor climate.

In terms of construction, these models prioritize durability and longevity. They feature robust insulation and high-quality materials, which contribute to their energy efficiency and operational lifespan. The compact design also allows for flexible installation options, making them suitable for various types of spaces.

Overall, the Regency P121RC, P121, P131, and P121LC represent the pinnacle of modern HVAC technology, blending efficiency, innovative features, and user-friendly control options to provide optimal comfort in any setting. As homeowners and businesses increasingly prioritize sustainability and energy management, these models are set to play a vital role in achieving a more comfortable and eco-friendly future.